Background: The purpose of this work was to propose an approach based on noise measurement to adapt present clinical acquisition and reconstruction parameters adapted to a PMT-based system (Biograph mCT) to a SiPM-based system (Biograph Vision 450) sharing identical geometrical properties. The NEMA performance (NEMA) of the recently released Biograph Vision 450 PET/CT (Vision) was also derived.
Methods: All measurements were conducted on Vision and Biograph mCT with TrueV (mCT).
Cardiac PET/CT is an evolving, non-invasive imaging modality that impacts patient management in many clinical scenarios. Beyond offering the capability to assess myocardial perfusion, inflammatory cardiac pathologies, and myocardial viability, cardiac PET/CT also allows for the non-invasive quantitative assessment of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Recognizing the need for an enhanced comprehension of coronary physiology, Siemens Healthineers implemented a sophisticated solution for the calculation of MBF and MFR in 2009.
View Article and Find Full Text PDFTime-of-flight (TOF) measurement capability promises to improve PET image quality. We characterized the physical and clinical PET performance of the first Biograph mCT TOF PET/CT scanner (Siemens Medical Solutions USA, Inc.) in comparison with its predecessor, the Biograph TruePoint TrueV.
View Article and Find Full Text PDFUnlabelled: Quantitative imaging biomarkers could speed the development of new treatments for unmet medical needs and improve routine clinical care. However, it is not clear how the various regulatory and nonregulatory (eg, reimbursement) processes (often referred to as pathways) relate, nor is it clear which data need to be collected to support these different pathways most efficiently, given the time- and cost-intensive nature of doing so. The purpose of this article is to describe current thinking regarding these pathways emerging from diverse stakeholders interested and active in the definition, validation, and qualification of quantitative imaging biomarkers and to propose processes to facilitate the development and use of quantitative imaging biomarkers.
View Article and Find Full Text PDFA tube-voltage-dependent scheme is presented for transforming Hounsfield units (HU) measured by different computed tomography (CT) scanners at different x-ray tube voltages (kVp) to 511 keV linear attenuation values for attenuation correction in positron emission tomography (PET) data reconstruction. A Gammex 467 electron density CT phantom was imaged using a Siemens Sensation 16-slice CT, a Siemens Emotion 6-slice CT, a GE Lightspeed 16-slice CT, a Hitachi CXR 4-slice CT, and a Toshiba Aquilion 16-slice CT at kVp ranging from 80 to 140 kVp. All of these CT scanners are also available in combination with a PET scanner as a PET/CT tomograph.
View Article and Find Full Text PDFUnlabelled: To optimize the injected dose of radiopharmaceutical in PET, one needs to know its relationship to some metric of data quality for individual patient scans, such as noise-equivalent counting rate (NECR). In this paper, we show how one may accurately model the clinical NECR response corresponding to specific patient scans much as if a counting-rate test had been performed on each patient. We apply this technique to patient data and show how it can lead to improved clinical scanning protocols.
View Article and Find Full Text PDFTime-of-flight (TOF) positron emission tomography (PET) was studied and preliminarily developed in the 1980s, but the lack of a scintillator able to deliver at the same time proper time resolution and stopping power has prevented this technique from becoming widespread and commercially available. With the introduction of LSO in PET, TOF is now a feasible option. TOF reconstruction has been implemented in the CPS Hi-Rez PET scanner, both with 2D filtered-back-projection (FBP2D) and 3D ordered subset expectation maximization (OSEM3D).
View Article and Find Full Text PDFPerformance tests on lutetium oxyorthosilicate (LSO)-based PET scanners cannot be conducted strictly according to the National Electrical Manufacturers Association (NEMA) NU 2 standards because of the presence of intrinsic radioactivity within the LSO crystal scintillator material. This background radiation gives rise mainly to random coincidence events but also to a small number of true coincidences, which cannot be eliminated from measurements on such scanners and must therefore be corrected for in the data analysis. The current NU 2 standards do not take account of these backgrounds and hence can lead to erroneous results on LSO-based machines.
View Article and Find Full Text PDFUnlabelled: The noise equivalent count (NEC) rate index is used to derive guidelines on the optimal injected dose to the patient for 2-dimensional (2D) and 3-dimensional (3D) whole-body PET acquisitions.
Methods: We performed 2D and 3D whole-body acquisitions of an anthropomorphic phantom modeling the conditions for (18)F-FDG PET of the torso and measured the NEC rates for different activity levels for several organs of interest. The correlations between count rates measured from the phantom and those from a series of whole-body patient scans were then analyzed.
We implemented a hybrid scatter-correction method for 3D PET that combines two scatter-correction methods in a complementary way. The implemented scheme uses a method based on the discrimination of the energy of events (the estimation of trues method (ETM)) and an auxiliary method (the single scatter simulation method (SSSI) or the convolution-subtraction method (CONV)) in an attempt to increase the accuracy of the correction over a wider range of acquisitions. The ETM takes into account the scatter from outside the field-of-view (FOV), which is not estimated with the auxiliary method.
View Article and Find Full Text PDFThe calculation of the intrinsic efficiency of individual crystals is one of the steps needed to obtain accurate images of the radioisotope distribution in positron emission tomography (PET). These efficiencies can be computed by comparing the number of coincidence counts obtained when the crystals are equally illuminated by the same source. However, because the number of coincidence counts acquired for one crystal also depends on the efficiency of the other crystals in coincidence, most methods of crystal efficiency calculation need to assume that the influence of the other crystals is negligible.
View Article and Find Full Text PDFIdeally, reliable quantitation in single-photon emission tomography (SPET) requires both emission and transmission data to be scatter free. Although scatter in emission data has been extensively studied, it is not well known how scatter in transmission data affects relative and absolute quantitation in reconstructed images. We studied SPET quantitative accuracy for different amounts of scatter in emission and transmission data using a Utah phantom and a cardiac Data Spectrum phantom including different attenuating media.
View Article and Find Full Text PDFLongitudinal positron emission tomography (PET) studies of 6-18F-L-dopa uptake in the striatum are used to assess the progression of Parkinson's disease or the survival of neuronal cells grafted in parkinsonian patients. These studies are performed over several years, and data analysis may suffer from the change from old tomographs to new machines with better sensitivity and spatial resolution. Furthermore, such studies on parkinsonian patients may be accomplished in either 2D or 3D acquisition mode.
View Article and Find Full Text PDFEpidepride labelled with iodine-123 is a suitable probe for the in vivo imaging of striatal and extrastriatal dopamine D2 receptors using single-photon emission tomography (SPET). Recently, this molecule has also been labelled with carbon-11. The goal of this work was to develop a method allowing the in vivo quantification of radioactivity uptake in baboon brain using SPET and to validate it using positron emission tomography (PET).
View Article and Find Full Text PDFState of the art positron emission tomography (PET) systems allow for scatter and attenuation correction. However, the size of the structure being studied and the region of interest (ROI) chosen also influence the accuracy of measurements of radioactive concentration. Furthermore, the limited spatial resolution of PET tomographs, which depends, among other factors, on the range of positrons in matter, can also contribute to a loss in quantitation accuracy.
View Article and Find Full Text PDFThe purpose of this study was to investigate the relative influence of scatter, attenuation, depth-dependent collimator response and finite spatial resolution upon the image characteristics in cardiac single-photon emission tomography (SPET). An acquisition of an anthropomorphic cardiac phantom was performed together with corresponding SPET Monte Carlo simulations. The cardiac phantom and the Monte Carlo simulations were designed so that the effect of scatter, attenuation, depth-dependent collimator response and finite spatial resolution could be studied individually and in combination.
View Article and Find Full Text PDFSeveral algorithms have been proposed to improve positron emission tomography quantification by combining anatomical and functional information in a pixel-by-pixel correction scheme. The precision of these methods when applied to real data depends on the precision of the manifold correction steps, such as full-width half-maximum modeling, magnetic resonance imaging-positron emission tomography registration, tissue segmentation, or background activity estimation. A good understanding of the influence of these parameters thus is critical to the effective use of the algorithms.
View Article and Find Full Text PDFThe multi-injection approach has been used to study in baboon the in vivo interactions between the D2 receptor sites and FLB 457, a ligand with a very high affinity for these receptors. The model structure was composed of four compartments (plasma, free ligand, and specifically and unspecifically bound ligands) and seven parameters (including the D2 receptor site density). The arterial plasma concentration, after correction for metabolites, was used as the input function.
View Article and Find Full Text PDFQuantification in positron emission tomography (PET) and single photon emission tomographic (SPET) relies on attenuation correction which is generally obtained with an additional transmission measurement. Therefore, the evaluation of the radiation doses received by patients needs to include the contribution of transmission procedures in SPET (SPET-TM) and PET (PET-TM). In this work we have measured these doses for both PET-TM and SPET-TM.
View Article and Find Full Text PDFDespite recent advances, the contribution of medical imaging techniques is limited, particularly in terms of tissue characterization, in the diagnosis of pulmonary nodules and search for extension of bronchogenic cancer. The metabolic properties of the glucose analog deoxyglucose labeled with 18F1 would allow metabolic imaging. Positron emission tomography (PET) provides clinicians with quality images with an interesting sensitivity.
View Article and Find Full Text PDFThree-dimensional (3D) positron emission tomography (PET) is attractive for [18F]fluoro-DOPA studies, since the sensitivity improvement is maximal for radioactive sources located in central planes, which is usually the case for the human striata. However, the image quantitation in that mode must be assessed because of the nearly threefold increase in scattered coincidences. We report the results of [18F]fluoro-DOPA studies performed on six normal volunteers.
View Article and Find Full Text PDFJ Cereb Blood Flow Metab
March 1997
The in vivo quantification of the benzodiazepine receptor concentration in human brain using positron emission tomography (PET) and 11C-flumazenil (11C-FMZ), is usually based on a three-compartment model and on PET curves measured in a small number of large regions of interest; however, it should be interesting to estimate the receptor concentration for each pixel and to build quantified images of the receptor concentration. The main advantage is to allow screening of the receptor site localization and visual observation of the possible abnormalities. Up to now, all the methods described include complex experimental protocols, difficult to use in routine examinations.
View Article and Find Full Text PDFUnlabelled: PET is potentially very useful for the accurate in vivo quantitation of time-varying biological distributions of radiolabeled antibodies over several days. The short half-lives of most commonly used positron-emitting nuclides make them unsuitable for this purpose. Iodine-124 is a positron emitter with a half-life of 4.
View Article and Find Full Text PDF