Publications by authors named "Bende T"

Purpose: Our study presents a digitised tangent screen test for ocular motility analysis according to the Harms and Hess tests (measurement of the squint angle in all fields of vision). This test uses an image beamer to display the tangent screen, a position sensor to measure the patient's head orientation, and a distance sensor to measure the fixation distance. Digital measurement of head orientation allows for a test procedure that eliminates the conventional requirement for a light pointer in the patient's hand.

View Article and Find Full Text PDF

In this work an enhanced wide range dual band spectral domain optical coherence tomography technique (SD-OCT) is presented to increase the depth and accuracy of the measurement of optical A-scan biometry. The setup uses a Michelson interferometer with two wide-spectrum Superluminescent Diodes (SLD). The emissions of the SLDs are filtered by a long-pass filter (900 nm) in front of the reference mirror.

View Article and Find Full Text PDF

Purpose: In this study, two intraocular lenses (spherical IOL SA60AT and aspherical IOL SN60WF) are examined in an eye model under conditions of misalignment (defocus, decentration and tilt). The lenses are rated using the contrast sensitivity function (CSF) based on Barten's physical model. The square root integral (SQRI) method is used as a quality criterion comparable to the subjective image quality assessment of the human eye.

View Article and Find Full Text PDF

Purpose: The study aimed to construct a new retinal tack design with high retention forces to prevent spontaneous disentanglement in cases of complicated retinal surgery.

Methods: Six new forms for the peak of a retinal tack were developed using computer-aided design (CAD); then a prototype was produced for each model. Finally, standardised design testing was conducted using human (ex vivo) sclera by logging 15 consecutive measurements for each model.

View Article and Find Full Text PDF

Purpose: To introduce additional steps towards smart laser control in eye surgery, with the use of the cosine similarity technique to analyze the spectra of organic polymers obtained using non-contact photoacoustic spectroscopy (NCPAS).

Methods: The experiments were performed with two organic polymers: polyethylene and polyamide. A 193 nm excimer laser was used for photoablation at a repetition rate of 200Hz.

View Article and Find Full Text PDF

This study reviews the development of Swept-Source interferometers and compares systematically three different Swept-Source interferometer designs for biometric measurements of the eye. Principles characteristics, conveniences and accessibilities of the three developed systems are presented. The main difference between the three Swept-Source systems is the method of tuning the wavelength at the broadband optical amplifier.

View Article and Find Full Text PDF

Objective: In the foveola of the eye, photoreceptors and Müller cells with a unique morphology have been described, but little is known about their 3D structure and orientation. Considering that there is an angle-dependent change in the foveolar photoreceptor response for the same light beam, known as the Stiles Crawford Effect of the first kind (SCE I), which is still not fully understood, a detailed analysis of the anatomy of the foveolar cells might help to clarify this phenomenon.

Methods: Serial semithin and ultrathin sections, and focused ion beam (FIB) tomography were prepared from 32 foveolae from monkeys () and humans.

View Article and Find Full Text PDF

The gradual process in which the crystalline lens is cloudy due to the appearance of elements giving rise to variations in the refractive index is known as cataract. Clinical assessment is usually complicated because it considers patient's perception, and individuals with similar development have different visual deficits. This work presents a model which considers the fluctuations in the refractive index as spherical particles produce measurable scatter radial profiles patterns on the retina.

View Article and Find Full Text PDF

Purpose: The aim of this study is to present a feasibility study to evaluate and compare a self-constructed, digital-based tangent scale using the Harms tangent screen test for the examination of patients' strabismus angles.

Methods: The documented strabismus angles of 10 patients were measured at nine gaze-positions and compared using the Harms tangent screen test (Harms Screen) and a self-constructed digital screen test (Digital Screen). The primary outcome is the difference in the measured angles between both methods.

View Article and Find Full Text PDF

Purpose: To investigate the use of a head-fixed feedback sensor to improve good positioning times after macular hole or retinal detachment surgery. The instructional methods, macular hole closure rates, and questionnaire responses were also evaluated.

Methods: After randomization, sensor devices with different feedback types (none/acoustic/vibration) were fixed on the patients' heads.

View Article and Find Full Text PDF

Background: This paper presents preliminary observations on the use of a commercial pupillometric instrument (Albomed PupilX) for the detection and quantification of Relative Afferent Pupillary Defect (RAPD). In this pilot study, video-based pupillometry was used in conjunction with calibrated LED illumination to simulate the effects of the traditional swinging-flashlight test using neutral density filters.

Methods: The results presented in this study follow a method described by Wilhelm et al.

View Article and Find Full Text PDF

In this study, a "time domain" system based on a partial coherence interferometry method is presented. The classic technique of varying the reference arm using a linear motor is replaced by the use of a rotating glass cube. The theoretical definition of the variation of the optical path length and first measurements in a human model eye and a real human eye are presented.

View Article and Find Full Text PDF

In this article, a swept-source setup based on a semiconductor optical amplifier at the central wavelength of 1050 nm for measurements of the axial length inside the eye is presented. The large coherence length is achieved using a tunable optical filter, consisting of a reflective diffraction grating, two Littrow prisms, and a scanner. It was possible to achieve a coherence length of 40 mm, which allowed interference measurements in this range to be made.

View Article and Find Full Text PDF

Background: Since 1982, the indirect binocular ophthalmoscope designed by Foerster has been in use in ophthalmology. The option to implement a new illumination technique using a light-emitting diode (LED) and a new power source should be evaluated in terms of technical feasibility and patient safety.

Methods: The cooling element was redesigned to accommodate the new LED electronics and their components, including an option for a variable brightness control.

View Article and Find Full Text PDF

Introduction: Optical biometry for calculation of intraocular lenses (IOL) was introduced by Zeiss with the IOLMaster. A newly developed system combines both video topography and optical coherence biometry (BioTop). This allows not only the conventional calculation of IOLs but also enables the design of customised IOLs based on ray-tracing.

View Article and Find Full Text PDF

We present a setup to measure biometric data of the eye using Fourier domain interferometry. The measuring depth of a Fourier domain system is basically limited owing to the spectral resolution. Combining two spectral domain interferometers with different wavelength ranges creates two measurement sections and allows for a simultaneous biometric measurement in terms of corneal thickness, anterior chamber depth, and axial length.

View Article and Find Full Text PDF

Purpose: To investigate the recently reported discrepancy between theoretical expectations and clinical outcomes of corneal ablations after excimer laser corneal refractive surgery.

Methods: Thirty-four eyes of 25 patients who had laser epithelial keratomileusis (LASEK) for myopia (mean -6.26±2.

View Article and Find Full Text PDF

Purpose: To calculate the exact geometry of custom intraocular lenses (IOLs) for pseudophakic eyes and theoretically predict the residual wavefront error by real ray tracing based on Snell's law.

Setting: Centre for Ophthalmology, University Hospital, Tübingen, Germany.

Methods: Individual computer models were constructed based on measurements, including corneal topography and axial length.

View Article and Find Full Text PDF

Type 1 interferons (IFN) bind specifically to the corresponding receptor, IFNAR. Agonists and antagonists for IFNAR have potential therapeutic value in the treatment of viral infections and systemic lupus erythematosus, respectively. Specific sequences on the surface of IFN, IFN receptor recognition peptides (IRRPs) mediate the binding and signal transduction when IFN interacts with IFNAR.

View Article and Find Full Text PDF

Purpose: An implementation of real ray tracing based on Snell's law is tested by predicting the refraction of pseudophakic eyes and calculating the geometry of intraocular lenses (IOLs).

Methods: The refraction of 30 pseudophakic eyes was predicted with the measured corneal topography, axial length, and the known IOL geometry and compared to the manifest refraction. Intraocular lens calculation was performed for 30 normal eyes and 12 eyes that had previous refractive surgery for myopia correction and compared to state-of-the-art IOL calculation formulae.

View Article and Find Full Text PDF

Purpose: We performed a prospective, nonrandomized investigation of contact continuous wave diode laser thermal keratoplasty (DTK) for correction of hyperopia and hyperopic astigmatism. The goal of surgery was not to achieve emmetropia but to investigate the refractive effect in patients younger than 40 years.

Methods: Twenty eyes with spherical hyperopia (Group A) and 15 eyes with hyperopic astigmatism (Group B) were treated with two rings; treatment zone diameter of the inner ring was 6 or 7 mm.

View Article and Find Full Text PDF

Background: In clinical practice ophthalmologists often need a tonometer which is independent of a slit lamp. Such a hand-held device is the Tono-Pen. We compared the precision of two equal Tono-Pens with Goldmann applanation tonometry.

View Article and Find Full Text PDF

Background: IR-photothermal ablation has, for some time, been described as an alternative to UV photoablation with Excimer lasers. Both procedures are based on different laser-tissue-interactions. IR solid state lasers have cost advantages over UV laser technology and allow a broader clinical use.

View Article and Find Full Text PDF

Dielectric spectroscopy is a non-invasive contact technique that permits the in vivo measurement of the specific electrical properties of biological tissue induced by an external electrical field. Permittivity, relaxation time and specific conductivity as a function of corneal hydration (wet weight/dry weight) and temperature were measured in 10 porcine corneas. Variation of tissue hydration has a minor influence on the signal, with a significant variation of the signal being detectable only for relatively dry tissue.

View Article and Find Full Text PDF