Real-time respiratory tumor tracking as implemented in a robotic treatment unit is based on continuous optical measurement of the position of external markers and a correlation model between them and internal target positions, which are established with X-ray imaging of the tumor, or fiducials placed in or around the tumor. Correlation models are created with fifteen simultaneously measured external/internal marker position pairs divided over the respiratory cycle. Every 45-150 s, the correlation model is updated by replacing the three first acquired data pairs with three new pairs.
View Article and Find Full Text PDFPurpose: To propose a novel treatment approach, designated VMAT+, involving addition of <5 IMRT beams with computer-optimized non-coplanar orientations to VMAT, and evaluate it for liver Stereotactic Body Radiation Therapy (SBRT). VMAT+ is investigated as an alternative for (1) coplanar VMAT and (2) multi-beam non-coplanar treatment.
Methods/materials: For fifteen patients with liver metastases, VMAT+ plans were compared with (1) dual-arc VMAT and (2) 25-beam, non-coplanar treatment with computer-optimized beam orientations (25-NCP).
Background: Planning for Volumetric Modulated Arc Therapy (VMAT) may be time consuming and its use is limited by available staff resources. Automated multicriterial treatment planning can eliminate this bottleneck. We compared automatically created (auto) VMAT plans generated by Erasmus-iCycle to manually created VMAT plans for treatment of spinal metastases.
View Article and Find Full Text PDFStereotactic body radiotherapy is a highly technology-driven treatment modality. The wider availability of in-room imaging and advanced radiotherapy delivery techniques has led to more institutions offering stereotactic ablative therapy (SABR). While some technological challenges remain, the crucial point for the next generation of SABR clinical trials is that today's technology is used correctly and close to its optimal potential for accuracy.
View Article and Find Full Text PDFPurpose: To develop and validate fully automated generation of VMAT plan-libraries for plan-of-the-day adaptive radiotherapy in locally-advanced cervical cancer.
Material And Methods: Our framework for fully automated treatment plan generation (Erasmus-iCycle) was adapted to create dual-arc VMAT treatment plan libraries for cervical cancer patients. For each of 34 patients, automatically generated VMAT plans (autoVMAT) were compared to manually generated, clinically delivered 9-beam IMRT plans (CLINICAL), and to dual-arc VMAT plans generated manually by an expert planner (manVMAT).
Purpose: To quantify the impact of the degree of robustness against setup errors and range errors on organ-at-risk (OAR) dose and normal tissue complication probabilities (NTCPs) in intensity-modulated proton therapy for oropharyngeal cancer patients.
Material And Methods: For 20 oropharyngeal cases (10 unilateral and 10 bilateral), robust treatment plans were generated using 'minimax' worst-case optimization. We varied the robustness against setup errors ('setup robustness') from 1 to 7mm and the robustness against range errors ('range robustness') from 1% to 7% (+1mm).
Purpose: The "InCise™ multileaf-collimator (MLC)" is the first commercial MLC to be mounted on a robotic SRS/SBRT platform (CyberKnife). The authors assessed characteristics and performance of this novel device in a preclinical five months test period.
Methods: Commissioning beam data were acquired with unshielded diodes.
Unlabelled: Introdution: Variation in shape, position and treatment response of both tumor and organs at risk are major challenges for accurate dose delivery in radiotherapy. Adaptive radiotherapy (ART) has been proposed to customize the treatment to these motion/response patterns of the individual patients, but increases workload and thereby challenges clinical implementation. This paper reviews strategies and workflows for clinical and in silico implemented ART for prostate, bladder, gynecological (gyne) and ano-rectal cancers.
View Article and Find Full Text PDFBackground And Purpose: With the introduction of Intensity Modulated Radiotherapy (IMRT) and image-guided plan-of-the-day strategies, the treatment of cervical cancer has become more sensitive to intra-fraction uncertainties. In this study we quantified intra-fraction changes in cervix-uterus shape, bladder and rectum filling, and patient setup using pre- and post-fraction CBCT scans.
Materials And Methods: A total of 632 CBCT scans were analyzed for 16 patients with large tip-of-uterus displacement (>2.
Purpose: To report, from a retrospective analysis of prospectively collected data, on the feasibility, outcome, toxicity, and voice-handicap index (VHI) of patients with T1a glottic cancer treated by a novel intensity modulated radiation therapy technique developed at our institution to treat only the involved vocal cord: single vocal cord irradiation (SVCI).
Methods And Materials: Thirty patients with T1a glottic cancer were treated by means of SVCI. Dose prescription was set to 16 × 3.
Purpose: The purpose of this study was to verify clinical target volume--planning target volume (CTV-PTV) margins in single vocal cord irradiation (SVCI) of T1a larynx tumors and characterize inter- and intrafraction target motion.
Methods And Materials: For 42 patients, a single vocal cord was irradiated using intensity modulated radiation therapy at a total dose of 58.1 Gy (16 fractions × 3.
Purpose: To shorten delivery times of intensity modulated proton therapy by reducing the number of energy layers in the treatment plan.
Methods And Materials: We have developed an energy layer reduction method, which was implemented into our in-house-developed multicriteria treatment planning system "Erasmus-iCycle." The method consisted of 2 components: (1) minimizing the logarithm of the total spot weight per energy layer; and (2) iteratively excluding low-weighted energy layers.
Background And Purpose: In a published study on cervical cancer, 5-beam IMRT was inferior to single arc VMAT. Here we compare 9, 12, and 20 beam IMRT with single and dual arc VMAT.
Material And Methods: For each of 10 patients, automated plan generation with the in-house Erasmus-iCycle optimizer was used to assist an expert planner in generating the five plans with the clinical TPS.
Purpose: In the treatment of cervical cancer, large anatomical deformations, caused by, e.g., tumor shrinkage, bladder and rectum filling changes, organ sliding, and the presence of the brachytherapy (BT) applicator, prohibit the accumulation of external beam radiotherapy (EBRT) and BT dose distributions.
View Article and Find Full Text PDFPurpose: To evaluate the clinical implementation of an online adaptive plan-of-the-day protocol for nonrigid target motion management in locally advanced cervical cancer intensity modulated radiation therapy (IMRT).
Methods And Materials: Each of the 64 patients had four markers implanted in the vaginal fornix to verify the position of the cervix during treatment. Full and empty bladder computed tomography (CT) scans were acquired prior to treatment to build a bladder volume-dependent cervix-uterus motion model for establishment of the plan library.
Purpose: To develop and evaluate fully automated volumetric modulated arc therapy (VMAT) treatment planning for prostate cancer patients, avoiding manual trial-and-error tweaking of plan parameters by dosimetrists.
Methods And Materials: A system was developed for fully automated generation of VMAT plans with our commercial clinical treatment planning system (TPS), linked to the in-house developed Erasmus-iCycle multicriterial optimizer for preoptimization. For 30 randomly selected patients, automatically generated VMAT plans (VMATauto) were compared with VMAT plans generated manually by 1 expert dosimetrist in the absence of time pressure (VMATman).
Purpose: Setup, range, and anatomical uncertainties influence the dose delivered with intensity modulated proton therapy (IMPT), but clinical quantification of these errors for oropharyngeal cancer is lacking. We quantified these factors and investigated treatment fidelity, that is, robustness, as influenced by adaptive planning and by applying more beam directions.
Methods And Materials: We used an in-house treatment planning system with multicriteria optimization of pencil beam energies, directions, and weights to create treatment plans for 3-, 5-, and 7-beam directions for 10 oropharyngeal cancer patients.
Background And Purpose: Deformation and correlated target motion remain challenges for margin recipes in radiotherapy (RT). This study presents a statistical deformable motion model for multiple targets and applies it to margin evaluations for locally advanced prostate cancer i.e.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
December 2013
Purpose: To investigate how dose distributions for liver stereotactic body radiation therapy (SBRT) can be improved by using automated, daily plan reoptimization to account for anatomy deformations, compared with setup corrections only.
Methods And Materials: For 12 tumors, 3 strategies for dose delivery were simulated. In the first strategy, computed tomography scans made before each treatment fraction were used only for patient repositioning before dose delivery for correction of detected tumor setup errors.
Background: To investigate for prostate cancer patients the comparison of 'in-vivo' measured portal dose images (PDIs) with predictions based on a kilovoltage cone-beam CT scan (CBCT), acquired during the same treatment fraction, as an alternative for pre-treatment verification. For evaluation purposes, predictions were also performed using the patients' planning CTs (pCT).
Methods: To get reliable CBCT electron densities for PDI predictions, Hounsfield units from the pCT were mapped onto the CBCT, while accounting for non-rigidity in patient anatomy in an approximate way.
Unlabelled: Daily treatment plan selection from a plan library is a major adaptive radiotherapy strategy to account for individual internal anatomy variations. This strategy depends on the initial input images being representative for the variations observed later in the treatment course. Focusing on locally advanced prostate cancer, our aim was to evaluate if residual motion of the prostate (CTV-p) and the elective targets (CTV-sv, CTV-ln) can be prospectively accounted for with a statistical deformable model based on images acquired in the initial part of treatment.
View Article and Find Full Text PDFPurpose: To investigate the robustness of single vocal cord intensity modulated radiation therapy (IMRT) treatment plans for set-up errors, respiration, and deformation.
Material And Methods: Four-dimensional computed tomography (4D-CT) scans of 10 early glottic carcinoma patients, previously treated with conventional techniques, were used in this simulation study. For each patient a pre-treatment 4D-CT was used for IMRT planning, generating a reference dose distribution.
Purpose: To compare IMRT planning strategies for prostate cancer patients with metal hip prostheses.
Methods: All plans were generated fully automatically (i.e.
Purpose: To quantify improved salivary gland sparing for head and neck cancer patients using intensity-modulated radiotherapy (IMRT) plans based on integrated computerized optimization of beam orientations and intensity profiles. To assess if optimized nonzero couch angles also improve VMAT plans.
Methods: Our in-house developed algorithm iCycle was used for automated generation of multicriterial optimized plans with optimized beam orientations and intensity profiles, and plans with optimized profiles for preselected beam arrangements.
In a recent paper, we have published a new algorithm, designated 'iCycle', for fully automated multi-criterial optimization of beam angles and intensity profiles. In this study, we have used this algorithm to investigate the relationship between plan quality and the extent of the beam direction search space, i.e.
View Article and Find Full Text PDF