Pacing Clin Electrophysiol
February 2024
Background: Conduction system pacing (CSP) is increasingly utilized to prevent and correct dyssynchrony. Barriers to CSP adoption include limited training, methodologic variability, laboratory slot allocation, and few data on learning curves. We report learning curves/clinical outcomes from a single experienced electrophysiologist who was new to CSP, and share gained insights.
View Article and Find Full Text PDFRadiol Cardiothorac Imaging
December 2023
Mitral annular disjunction (MAD) refers to atrial displacement of the hinge point of the mitral valve annulus from the ventricular myocardium. MAD leads to paradoxical expansion of the annulus in systole and may often be associated with mitral valve prolapse (MVP), leaflet degeneration, myocardial and papillary muscle fibrosis, and, potentially, malignant cardiac arrhythmias. Patients with MAD and MVP may present similarly, and MAD is potentially the missing link in explaining why some patients with MVP experience adverse outcomes.
View Article and Find Full Text PDFBackground: This meta-analysis compares His-Purkinje system pacing (HPSP), a novel cardiac resynchronization therapy (CRT) technique that targets the intrinsic conduction system of the heart, with conventional biventricular pacing (BiVP) in heart failure (HF) patients with left ventricular (LV) dysfunction and dyssynchrony.
Methods: We searched multiple databases up to May 2023 and identified 18 studies (five randomized controlled trials and 13 observational studies) involving 1291 patients. The outcome measures were QRS duration, left ventricular ejection fraction (LVEF) improvement, left ventricular end-diastolic diameter (LVEDD) change, HF hospitalization, and New York Heart Association (NYHA) functional class improvement.
Evidence on the relative safety and efficacy of atrial fibrillation catheter ablation and antiarrhythmic drugs (AADs) as the first-line therapy for patients with treatment-naive atrial fibrillation (AF) remains disputed. Digital databases were queried to identify relevant randomized controlled trials. The incidence of recurrent AF, major adverse cardiovascular events, and its components (all-cause death, nonfatal stroke, and bleeding) were compared using the DerSimonian and Laird method under the random-effects model to calculate pooled unadjusted risk ratio (RR) with 95% confidence intervals (CIs).
View Article and Find Full Text PDFBackground: In 1982, Drs. Barold and Goldberger described an ECG triad associated with left ventricular dysfunction (LVD) consisting of high precordial QRS voltage, low limb lead voltage, and poor precordial R wave progression. Studies have since attempted to replicate the originally reported sensitivity (70%), specificity (>99%), and positive predictive value (PPV, 100%) of Goldberger's triad (GT) with variable results.
View Article and Find Full Text PDFAims: Atrial fibrillation (AF) in patients with cardiac amyloidosis (CA) has been linked with a worse prognosis. The current study aimed to determine the outcomes of AF catheter ablation in patients with CA.
Methods And Results: The Nationwide Readmissions Database (2015-2019) was used to identify patients with AF and concomitant heart failure.
Coronavirus disease 2019 (COVID-19) is associated with pulmonary involvement and cardiac arrhythmias, including supraventricular tachycardia (SVT). Adenosine is commonly used to treat SVT and is generally safe, but is rarely associated with bronchospasm. There are no data regarding the safety of adenosine use in patients with COVID-19 pneumonia and physicians may hesitate to use it in such patients.
View Article and Find Full Text PDFA nation's health and economic development are inextricably and synergistically connected. Stark differences exist between wealthy and developing nations in the use of cardiac implantable electronic devices (CIEDs). Cardiovascular disease is now the leading cause of death in low- and middle-income countries (LMIC), with a significant burden from rhythm-related diseases.
View Article and Find Full Text PDFPurpose Of The Review: Dyssynchrony occurs when portions of the cardiac chambers contract in an uncoordinated fashion. Ventricular dyssynchrony primarily impacts the left ventricle and may result in heart failure. This entity is recognized as a major contributor to the development and progression of heart failure.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
May 2022
Introduction: Although uncommonly encountered, dual atrioventricular nodal non-reentrant tachycardia (DAVNNRT) is a well-described arrhythmia that can manifest in patients with dual atrioventricular nodal pathways physiology. This arrhythmia is characterized on electrocardiogram (ECG) by a single P wave followed by two conducted QRS complexes (so-called "double fire"), and on intracardiac electrograms by a single atrial electrogram followed by two separate His deflections and ventricular electrograms.
Methods/results: We report a rare case of "triple-fire" atrioventricular non-reentrant tachycardia in which a patient was found to have three distinct atrioventricular nodal pathways and multiple triple fire responses, both on surface ECG and intracardiac electrograms.
J Cardiovasc Electrophysiol
February 2022
Introduction: His-bundle pacing (HBP) and left-bundle-area pacing (LBAP) are conduction system pacing (CSP) modalities increasingly used as alternatives to conventional biventricular pacing (BiVP). While effects of CSP on ventricular depolarization have been reported, effects on ventricular repolarization have not.
Methods: QRS duration (QRSd) and validated ECG parameters of ventricular repolarization associated with arrhythmic risk (T-peak-to-T-end , T-peak-to-T-end , T-peak dispersion, QTc, QTc dispersion) were analyzed post-implant in 107 patients: 60 with CSP (HBP: n = 35, LBAP: n = 25) and 47 with BiVP.
Introduction: Myriad cardiovascular manifestations have been reported with COVID-19. We previously reported that failure of PR interval shortening with increasing heart rate (HR) in patients with COVID-19 is associated with adverse outcomes. Here, we report on heart rate variability (HRV) and clinical outcomes in patients with chronic atrial fibrillation (cAF) hospitalized for COVID-19.
View Article and Find Full Text PDFWe report a unique case of delivery of inappropriate implantable cardioverter-defibrillator therapies related to a "perfect storm": presence of an integrated lead, insufficient lead slack related to right heart dilation resulting in shock coil misplacement, myocarditis with loss of R waves, and the concomitant occurrence of an incessant atrial tachycardia. ().
View Article and Find Full Text PDFVagal activation usually affects both sinus and atrioventricular (AV) nodes, manifesting as sinus slowing accompanied by varying degrees of AV block. AV block accompanying sinus acceleration as during treadmill testing is usually considered pathologic. We report 2 cases of vagally mediated reflex AV block accompanied by sinus tachycardia and acceleration.
View Article and Find Full Text PDFBackground: Implantable cardioverter defibrillator (ICD) and permanent pacemaker (PPM) lead placement may worsen or result in tricuspid regurgitation (TR). While the association between lead placement and the incidence of TR has been established, current understanding of this problem remains incomplete. This systematic review and meta-analysis sought to pool the existing evidence to better understand the occurrence and severity of TR associated with cardiac implantable electrical device (CIED) insertion.
View Article and Find Full Text PDFManufacturers of cardiac implantable electronic devices have incorporated automatic features to allow for remote monitoring, improve device longevity, and additional safety. Algorithms to automatically measure capture threshold and adjust output to preserve battery life are one such feature. Automatic features may occasionally result in unexpected or undesirable clinical outcomes.
View Article and Find Full Text PDFMany patients with continuous-flow left ventricular assist devices (CF-LVAD) have other, co-existing implantable cardiac devices. While such devices often function appropriately, there is potential for electromagnetic interference (EMI). A literature review was performed to identify cases of EMI between CF-LVAD and other implanted cardiac devices to better understand their etiology, outcomes, and the strategies used to overcome such interference.
View Article and Find Full Text PDFJ Electrocardiol
June 2021
We report of case of an 87 year old lady with preexisting RBBB who developed LBBB after transcatheter aortic valve replacement (TAVR) for the treatment of severe aortic stenosis. She underwent pacemaker implantation, and subsequently developed high-grade atrioventricular (AV) block. Dual chamber pacing in the setting of complete heart block with a long programmed AV delay showed retrograde P waves.
View Article and Find Full Text PDFPurpose: To report on the clinical utility of implantable loop recorders (ILRs) in a large academic hospital setting over a 4-year period.
Methods: Retrospective study (2013-2016) of patients receiving ILRs for any indication including syncope, cryptogenic stroke (CrS), atrial fibrillation (AF) burden, palpitations, ventricular arrhythmias (VA), and other. Remote checks, symptomatic transmissions, and in-person checks were reviewed.
Pacing Clin Electrophysiol
September 2020
Objective: This study evaluated the risk of subclinical atrial fibrillation (AF) in patients with central retinal artery occlusion (CRAO) compared to those with cryptogenic stroke using implantable loop recorders (ILR).
Methods: We conducted a retrospective analysis of 273 consecutive patients who had ILRs inserted at our institution for either cryptogenic stroke (n = 227) or CRAO (n = 46). Our primary endpoint was a time to event analysis for the new diagnosis of AF by ILR.
Background: Myriad manifestations of cardiovascular involvement have been described in patients with coronavirus disease 2019 (COVID-19), but there have been no reports of COVID-19 affecting the cardiac conduction system. The PR interval on the electrocardiogram (ECG) normally shortens with increasing heart rate (HR). The case of a patient with COVID-19 manifesting Mobitz type 1 atrioventricular (AV) block that normalized as the patient's condition improved prompted us to investigate PR interval behavior in patients with COVID-19.
View Article and Find Full Text PDF