As nitrogen discharge limits are becoming more stringent, short-cut nitrogen systems and tertiary nitrogen polishing steps are gaining popularity. For partial nitritation or nitritation-denitritation systems, anaerobic ammonia oxidation (anammox) polishing may be feasible to remove residual ammonia and nitrite from the effluent. Nitrogen polishing of mainstream nitritation-denitritation system effluent via anammox was studied at 25°C in a fully anoxic moving bed bioreactor (MBBR) (V = 0.
View Article and Find Full Text PDFThis paper deals with an almost 1-year long pilot study of a nitritation-denitritation process that was followed by anammox polishing. The pilot plant treated real municipal wastewater at ambient temperatures. The effluent of high-rate activated sludge process (hydraulic retention time, HRT=30 min, solids retention time=0.
View Article and Find Full Text PDFThis work describes the development of an intermittently aerated pilot-scale process (V = 0.34 m(3)) operated without oxidized nitrogen recycle and supplemental carbon addition optimized for nitrogen removal via nitritation/denitritation. The aeration pattern was controlled using a novel aeration strategy based on set-points for reactor ammonia, nitrite and nitrate concentrations with the aim of maintaining equal effluent ammonia and nitrate + nitrite (NOx) concentrations.