The study aimed to evaluate the stress levels on implants and surrounding bone in different All-on-4 surgical techniques using 3D finite element analysis.
A 3D model of the upper jaw was created to analyze four different implant configurations and subjected to various force directions.
Results indicated that bicortical implant placement generally reduced stress on the bone and implant-abutment system compared to conventional techniques, particularly under vertical and oblique loading conditions.