Background: Rapid identification of individuals with acute respiratory infections is crucial for preventing nosocomial infections. For rapid diagnosis, especially in EDs, lateral flow devices (LFDs) are a convenient, inexpensive option with a rapid turnaround. Several 'multiplex' LFDs (M-LFDs) now exist, testing for multiple pathogens from a single swab sample.
View Article and Find Full Text PDFRapid and accessible testing was paramount in the management of the COVID-19 pandemic. Our university established KCL TEST: a SARS-CoV-2 asymptomatic testing programme that enabled sensitive and accessible PCR testing of SARS-CoV-2 RNA in saliva. Here, we describe our learnings and provide our blueprint for launching diagnostic laboratories, particularly in low-resource settings.
View Article and Find Full Text PDFInt J Syst Evol Microbiol
December 2023
A novel bacterial strain, GSTT-20 was isolated from an infected, prosthetic endovascular graft explanted from a shepherd in London, United Kingdom. This strain was an aerobic, catalase-positive, oxidase-negative, Gram-stain-negative, motile, curved rod. It grew on blood agar, chocolate agar and MacConkey agar incubated at 37 °C in an aerobic environment after 48 h, appearing as yellow, mucoid colonies.
View Article and Find Full Text PDFAm J Respir Crit Care Med
January 2024
Respiratory metagenomics (RMg) needs evaluation in a pilot service setting to determine utility and inform implementation into routine clinical practice. Feasibility, performance, and clinical impacts on antimicrobial prescribing and infection control were recorded during a pilot RMg service. RMg was performed on 128 samples from 87 patients with suspected lower respiratory tract infection (LRTI) on two general and one specialist respiratory ICUs at Guy's and St Thomas' NHS Foundation Trust, London.
View Article and Find Full Text PDFMicrob Genom
August 2023
Rapid respiratory viral whole genome sequencing (WGS) in a clinical setting can inform real-time outbreak and patient treatment decisions, but the feasibility and clinical utility of influenza A virus (IAV) WGS using Nanopore technology has not been demonstrated. A 24 h turnaround Nanopore IAV WGS protocol was performed on 128 reverse transcriptase PCR IAV-positive nasopharyngeal samples taken over seven weeks of the 2022-2023 winter influenza season, including 25 from patients with nosocomial IAV infections and 102 from patients attending the Emergency Department. WGS results were reviewed collectively alongside clinical details for interpretation and reported to clinical teams.
View Article and Find Full Text PDFObjectives: Epidemiological and whole-genome sequencing analysis of an ongoing outbreak of Streptococcus pyogenes (Group A Streptococcus) in London (United Kingdom).
Methods: Prospective identification of Group A Streptococcus cases from a diagnostic laboratory serving central and south London between 27 November and 10 December 2022. Case notes were reviewed and isolates were retrieved.
The management of coronavirus disease 2019 has become more complex due to the expansion of available therapies. The presence of severe acute respiratory syndrome coronavirus 2 variants and mutations further complicates treatment due to their differing susceptibilities to therapies. Here we outline the use of real-time whole genome sequencing to detect persistent infection, evaluate for mutations confering resistance to treatments, and guide treatment decisions.
View Article and Find Full Text PDFNumerous studies have shown that a prior SARS-CoV-2 infection can greatly enhance the antibody response to COVID-19 vaccination, with this so called "hybrid immunity" leading to greater neutralization breadth against SARS-CoV-2 variants of concern. However, little is known about how breakthrough infection (BTI) in COVID-19-vaccinated individuals will impact the magnitude and breadth of the neutralizing antibody response. Here, we compared neutralizing antibody responses between unvaccinated and COVID-19-double-vaccinated individuals (including both AZD1222 and BNT162b2 vaccinees) who have been infected with the Delta (B.
View Article and Find Full Text PDFBackground: The Alpha variant (B.1.1.
View Article and Find Full Text PDFCOVID-19 vaccine design and vaccination rollout need to take into account a detailed understanding of antibody durability and cross-neutralizing potential against SARS-CoV-2 and emerging variants of concern (VOCs). Analyses of convalescent sera provide unique insights into antibody longevity and cross-neutralizing activity induced by variant spike proteins, which are putative vaccine candidates. Using sera from 38 individuals infected in wave 1, we show that cross-neutralizing activity can be detected up to 305 days pos onset of symptoms, although sera were less potent against B.
View Article and Find Full Text PDFThere is a worldwide need for reagents to perform SARS-CoV-2 detection. Some laboratories have implemented kit-free protocols, but many others do not have the capacity to develop these and/or perform manual processing. We provide multiple workflows for SARS-CoV-2 nucleic acid detection in clinical samples by comparing several commercially available RNA extraction methods: QIAamp Viral RNA Mini Kit (QIAgen), RNAdvance Blood/Viral (Beckman) and Mag-Bind Viral DNA/RNA 96 Kit (Omega Bio-tek).
View Article and Find Full Text PDFObjectives: To analyse nosocomial transmission in the early stages of the coronavirus 2019 (COVID-19) pandemic at a large multisite healthcare institution. Nosocomial incidence is linked with infection control interventions.
Methods: Viral genome sequence and epidemiological data were analysed for 574 consecutive patients, including 86 nosocomial cases, with a positive PCR test for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) during the first 19 days of the pandemic.
Background: Lateral flow devices (LFDs) for rapid antigen testing are set to become a cornerstone of SARS-CoV-2 mass community testing, although their reduced sensitivity compared with PCR has raised questions of how well they identify infectious cases. Understanding their capabilities and limitations is, therefore, essential for successful implementation. We evaluated six commercial LFDs and assessed their correlation with infectious virus culture and PCR cycle threshold (Ct) values.
View Article and Find Full Text PDFBackground: Development of an effective vaccine against the pathogenic blood-stage infection of human malaria has proved challenging, and no candidate vaccine has affected blood-stage parasitemia following controlled human malaria infection (CHMI) with blood-stage .
Methods: We undertook a phase I/IIa clinical trial in healthy adults in the United Kingdom of the RH5.1 recombinant protein vaccine, targeting the reticulocyte-binding protein homolog 5 (RH5), formulated in AS01 adjuvant.
Objectives: Assess the feasibility and impact of nanopore-based 16S rRNA gene sequencing (Np16S) service on antibiotic treatment for acute severe pneumonia on the intensive care unit (ICU).
Methods: Speciation and sequencing accuracy of Np16S on isolates with bioinformatics pipeline optimisation, followed by technical evaluation including quality checks and clinical-reporting criteria analysing stored respiratory samples using single-sample flow cells. Pilot service comparing Np16S results with all routine respiratory tests and impact on same-day antimicrobial prescribing.
As SARS-CoV-2 variants continue to emerge globally, a major challenge for COVID-19 vaccination is the generation of a durable antibody response with cross-neutralizing activity against both current and newly emerging viral variants. Cross-neutralizing activity against major variants of concern (B.1.
View Article and Find Full Text PDFBackground: Antimicrobial resistance (AMR) in is a global health threat. Capacity for individual-level surveillance remains limited in many countries, whilst population-level surveillance approaches could inform empiric antibiotic treatment guidelines.
Methods: In this exploratory study, a novel approach to population-level prediction of AMR in clinical isolates using metagenomic (Illumina) profiling of pooled DNA extracts from human faecal samples was developed and tested.
There is a worldwide need for reagents to perform SARS-CoV-2 detection. Some laboratories have implemented kit-free protocols, but many others do not have the capacity to develop these and/or perform manual processing. We provide multiple workflows for SARS-CoV-2 nucleic acid detection in clinical samples by comparing several commercially available RNA extraction methods: QIAamp Viral RNA Mini Kit (QIAgen), RNAdvance Blood/Viral (Beckman) and Mag-Bind Viral DNA/RNA 96 Kit (Omega Bio-tek).
View Article and Find Full Text PDFDuring the first wave of the global COVID-19 pandemic the clinical utility and indications for SARS-CoV-2 serological testing were not clearly defined. The urgency to deploy serological assays required rapid evaluation of their performance characteristics. We undertook an internal validation of a CE marked lateral flow immunoassay (LFIA) (SureScreen Diagnostics) using serum from SARS-CoV-2 RNA positive individuals and pre-pandemic samples.
View Article and Find Full Text PDF