Objective: Recent studies have shown that calculations of the percent free/total prostate-specific antigen (PSA) improves the specificity of PSA testing. Characterizing the variability of free PSA and total PSA is necessary to evaluate the utility of an isolated free/total PSA measurement. We investigated the total variation of free and total PSA levels to determine how the percent free/total PSA was affected.
View Article and Find Full Text PDFReticulocyte analysis by flow cytometry offers precision and sensitivity greater than those of conventional morphologic methods and permits derivation of a reticulocyte maturity index. However, interlaboratory variability has not yet been reported. The authors analyzed 310 samples at eight sites using 11 instruments over a 4-month period to examine intermethod and interlaboratory variabilities.
View Article and Find Full Text PDFWe modified the Hybritech Tandem-E prostate-specific antigen (PSA) assay by increasing the sample volume, increasing enzyme-substrate incubation time, and using diethanolamine buffer. Our modified method has a detection limit of 0.009 microgram/L (P < 0.
View Article and Find Full Text PDFThe objective of this study was to examine quantitative differences between the two commonly used methods for determining serum albumin concentration, bromcresol green (BCG) and bromcresol purple (BCP), in normal subjects and in 235 unselected dialysis patients in view of recently established Health Care Financing Administration (HCFA) quality assurance review criteria. The mean of normal results by the BCG method was 4.4 g/dL, and 97.
View Article and Find Full Text PDFClin Lab Haematol
March 1991
The Laboratory Accreditation Programme (LAP) offered by the College of American Pathologists (CAP) was begun in 1961. It is a voluntary peer review programme with the goal of laboratory improvement to excellence. It presently accredits more than 4300 laboratories throughout the world, although the majority are in the United States and Canada.
View Article and Find Full Text PDFArch Pathol Lab Med
June 1985
An electronic blood cell counter (Coulter S-plus IV) classifies leukocytes as lymphocytes, large mononuclear cells, or granulocytes based on volume after treatment with a reagent. Correlation coefficients as compared with stained film microscopy are .94 for lymphocytes, .
View Article and Find Full Text PDFWe describe the performance of an RIA for the measurement of prostate-specific antigen (PA). Between-assay precision (CV) for control sera with various analyte concentrations was as follows: mean = 1.67 micrograms/L, CV = 7.
View Article and Find Full Text PDFWe describe the performance of a commercial (Steranti/EIR) RIA reagent kit for measuring 17 beta-estradiol directly in serum. Day-to-day precision data for control sera were as follows: mean = 102.8 ng/L, CV = 6.
View Article and Find Full Text PDFWe describe an automated method for calcium assay, for use with the Cobas-Bio centrifugal analyzer. Calcium is reacted with cresolphthalein complexone and the absorbance of the calcium--dye complex at 575 nm is measured. EDTA is then added to break up the calcium--dye complex and the absorbance at 575 nm is re-measured, to correct for endogenous color and turbidity.
View Article and Find Full Text PDFProstatic acid phosphatase values in 98 patients with prostatic carcinoma were measured by a commercial radioimmunoassay (RIA) and by enzymatic assay. Forty-three carcinomas were staged by rigorous pathological criteria. Patients (N = 129) with benign prostatic hyperplasia were the control group.
View Article and Find Full Text PDFThe effects of three widely spaced levels of bacterial contamination of reagent water on several chemistry, radioimmunoassay, and coagulation procedures were studied. These included determinations of lactate dehydrogenase, creatine kinase, aspartate transaminase, alkaline phosphatase, blood urea nitrogen, total protein, thyroid-stimulating hormone, digoxin, thrombin time, activated partial thromboplastin time, and prothrombin time. Statistical analyses included calculations of means and coefficients of variation, and analysis of variance, as well as correlation coefficients for test results versus logarithm of bacterial contamination.
View Article and Find Full Text PDFAn 125I-radioimmunoassay is described which measures unconjugated estriol in the serum of pregnant women. Estriol is extracted into ethyl acetate/hexane, an aliquot is evaporated, and the residue is redissolved in phosphate buffer. The sample is incubated with tracer and antibody at 37 degrees C for 15 min and then at 4 degrees C for 1 h and 45 min.
View Article and Find Full Text PDFThe enzymatic cholesterol method used with the Du Pont aca has been modified to provide a reliable measurement of high-density lipoprotein cholesterol in serum after heparin/Mn2+ precipitation of the low- and very-low-density lipoproteins. Interference by Mn2+, equivalent to about 90 mg of cholesterol per liter, is decreased to less than 40 mg of cholesterol per liter by the presence of ethylenediaminetetraacetate (8 mmol/liter) in the diluent; the residual effect of Mn2+ is compensated by calibrating the aca with standards containing Mn2+ and heparin. With an 80-microliter sample, the sensitivity is 236 muA/mg per liter and linearity ranges from 50 to 1500 mg/liter.