Publications by authors named "Bartosz Mindur"

In this paper, we report on a systematic study of a soft X-ray Gas Electron Multiplier (GEM) detector built with aluminium-clad kapton GEM foils. The primary objective of this research is to comprehend the performance of this type of detector when irradiated with soft energy photons. The results are analysed and discussed with a particular focus on the long-term detector stability, as well as its gas gain and energy resolution uniformity across the detector area.

View Article and Find Full Text PDF

Local Field Potential (LFP), despite its name, often reflects remote activity. Depending on the orientation and synchrony of their sources, both oscillations and more complex waves may passively spread in brain tissue over long distances and be falsely interpreted as local activity at such distant recording sites. Here we show that the whisker-evoked potentials in the thalamic nuclei are of local origin up to around 6 ms post stimulus, but the later (7-15 ms) wave is overshadowed by a negative component reaching from cortex.

View Article and Find Full Text PDF

The goal of the work was to investigate the possible application of factor analysis methods for processing X-ray Fluorescence (XRF) data acquired with a full-field XRF spectrometer employing a position-sensitive and energy-dispersive Gas Electron Multiplier (GEM) detector, which provides only limited energy resolution at a level of 18% Full Width at Half Maximum (FWHM) at 5.9 keV. In this article, we present the design and performance of the full-field imaging spectrometer and the results of case studies performed using the developed instrument.

View Article and Find Full Text PDF

In this paper, we present a modular Data Acquisition (DAQ) system for simultaneous electrical stimulation and recording of brain activity. The DAQ system is designed to work with custom-designed Application Specific Integrated Circuit (ASIC) called Neurostim-3 and a variety of commercially available Multi-Electrode Arrays (MEAs). The system can control simultaneously up to 512 independent bidirectional i.

View Article and Find Full Text PDF

In this paper, we report on the systematic study of different variants of X-ray detectors based on GEM technology using modified GEM foils with greatly reduced amount of copper. The main goal of this study was understanding the performance of such detectors applied in X-Ray Fluorescence (XRF) elemental analysis. Reduction of the amount of copper in the detector structure is crucial for suppression of XRF background from copper, but one has to ensure that key detector parameters are not affected by such modification.

View Article and Find Full Text PDF