The success of deep learning on image classification and recognition tasks has led to new applications in diverse contexts, including the field of medical imaging. However, two properties of deep neural networks (DNNs) may limit their future use in medical applications. The first is that DNNs require a large amount of labeled training data, and the second is that the deep learning-based models lack interpretability.
View Article and Find Full Text PDFAccurate annotation of vertebral bodies is crucial for automating the analysis of spinal X-ray images. However, manual annotation of these structures is a laborious and costly process due to their complex nature, including small sizes and varying shapes. To address this challenge and expedite the annotation process, we propose an ensemble pipeline called VertXNet.
View Article and Find Full Text PDFDeformable image registration, the estimation of the spatial transformation between different images, is an important task in medical imaging. Deep learning techniques have been shown to perform 3D image registration efficiently. However, current registration strategies often only focus on the deformation smoothness, which leads to the ignorance of complicated motion patterns (e.
View Article and Find Full Text PDFMaturation of the human fetal brain should follow precisely scheduled structural growth and folding of the cerebral cortex for optimal postnatal function. We present a normative digital atlas of fetal brain maturation based on a prospective international cohort of healthy pregnant women, selected using World Health Organization recommendations for growth standards. Their fetuses were accurately dated in the first trimester, with satisfactory growth and neurodevelopment from early pregnancy to 2 years of age.
View Article and Find Full Text PDFDamage to cartilage is an important indicator of osteoarthritis progression, but manual extraction of cartilage morphology is time-consuming and prone to error. To address this, we hypothesize that automatic labeling of cartilage can be achieved through the comparison of contrasted and non-contrasted Computer Tomography (CT). However, this is non-trivial as the pre-clinical volumes are at arbitrary starting poses due to the lack of standardized acquisition protocols.
View Article and Find Full Text PDFMetastatic tumour progression is facilitated by tumour associated macrophages (TAMs) that enforce pro-tumour mechanisms and suppress immunity. In pulmonary metastases, it is unclear whether TAMs comprise tissue resident or infiltrating, recruited macrophages; and the different expression patterns of these TAMs are not well established. Using the mouse melanoma B16F10 model of experimental pulmonary metastasis, we show that infiltrating macrophages (IM) change their gene expression from an early pro-inflammatory to a later tumour promoting profile as the lesions grow.
View Article and Find Full Text PDFBrain extraction (masking of extra-cerebral tissues) and alignment are fundamental first steps of most neuroimage analysis pipelines. The lack of automated solutions for 3D ultrasound (US) has therefore limited its potential as a neuroimaging modality for studying fetal brain development using routinely acquired scans. In this work, we propose a convolutional neural network (CNN) that accurately and consistently aligns and extracts the fetal brain from minimally pre-processed 3D US scans.
View Article and Find Full Text PDFQuantitative cardiovascular magnetic resonance (CMR) T1 mapping has shown promise for advanced tissue characterisation in routine clinical practise. However, T1 mapping is prone to motion artefacts, which affects its robustness and clinical interpretation. Current methods for motion correction on T1 mapping are model-driven with no guarantee on generalisability, limiting its widespread use.
View Article and Find Full Text PDFPurpose: To use a novel segmentation methodology based on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to define tumour subregions of liver metastases from colorectal cancer (CRC), to compare these with histology, and to use these to compare extracted pharmacokinetic (PK) parameters between tumour subregions.
Materials And Methods: This ethically-approved prospective study recruited patients with CRC and ≥1 hepatic metastases scheduled for hepatic resection. Patients underwent DCE-MRI pre-metastasectomy.
Recent developments in laser scanning microscopy have greatly extended its applicability in cancer imaging beyond the visualization of complex biology, and opened up the possibility of quantitative analysis of inherently dynamic biological processes. However, the physics of image acquisition intrinsically means that image quality is subject to a tradeoff between a number of imaging parameters, including resolution, signal-to-noise ratio, and acquisition speed. We address the problem of geometric distortion, in particular, jaggedness artefacts that are caused by the variable motion of the microscope laser, by using a combination of image processing techniques.
View Article and Find Full Text PDFComput Med Imaging Graph
June 2019
Patch-based approaches have received substantial attention over the recent years in medical imaging. One of their potential applications may be to provide more anatomically consistent ventilation maps estimated on dynamic lung CT. An assessment of regional lung function may act as a guide for radiotherapy, ensuring a more accurate treatment plan.
View Article and Find Full Text PDFPurpose: Compensation for respiratory motion is important during abdominal cancer treatments. In this work we report the results of the 2015 MICCAI Challenge on Liver Ultrasound Tracking and extend the 2D results to relate them to clinical relevance in form of reducing treatment margins and hence sparing healthy tissues, while maintaining full duty cycle.
Methods: We describe methodologies for estimating and temporally predicting respiratory liver motion from continuous ultrasound imaging, used during ultrasound-guided radiation therapy.
Background: To determine the relative abilities of compartment models to describe time-courses of 18F-fluoromisonidazole (FMISO) tumor uptake in patients with advanced stage non-small cell lung cancer (NSCLC) imaged using dynamic positron emission tomography (dPET), and study correlations between values of the blood flow-related parameter K obtained from fits of the models and an independent blood flow measure obtained from perfusion CT (pCT). NSCLC patients had a 45-min dynamic FMISO PET/CT scan followed by two static PET/CT acquisitions at 2 and 4-h post-injection. Perfusion CT scanning was then performed consisting of a 45-s cine CT.
View Article and Find Full Text PDFTumor vessels influence the growth and response of tumors to therapy. Imaging vascular changes using dynamic contrast-enhanced MRI (DCE-MRI) has shown potential to guide clinical decision making for treatment. However, quantitative MR imaging biomarkers of vascular function have not been widely adopted, partly because their relationship to structural changes in vessels remains unclear.
View Article and Find Full Text PDFDeformable image registration, a key component of motion correction in medical imaging, needs to be efficient and provides plausible spatial transformations that reliably approximate biological aspects of complex human organ motion. Standard approaches, such as Demons registration, mostly use Gaussian regularization for organ motion, which, though computationally efficient, rule out their application to intrinsically more complex organ motions, such as sliding interfaces. We propose regularization of motion based on supervoxels, which provides an integrated discontinuity preserving prior for motions, such as sliding.
View Article and Find Full Text PDFIn this work we propose to combine a supervoxel-based image representation with the concept of graph cuts as an efficient optimization technique for 3D deformable image registration. Due to the pixels/voxels-wise graph construction, the use of graph cuts in this context has been mainly limited to 2D applications. However, our work overcomes some of the previous limitations by posing the problem on a graph created by adjacent supervoxels, where the number of nodes in the graph is reduced from the number of voxels to the number of supervoxels.
View Article and Find Full Text PDFAutomated analysis of structural imaging such as lung Computed Tomography (CT) plays an increasingly important role in medical imaging applications. Despite significant progress in the development of image registration and segmentation methods, lung registration and segmentation remain a challenging task. In this paper, we present a novel image registration and segmentation approach, for which we develop a new mathematical formulation to jointly segment and register three-dimensional lung CT volumes.
View Article and Find Full Text PDFOver the past 20 years, the field of medical image registration has significantly advanced from multi-modal image fusion to highly non-linear, deformable image registration for a wide range of medical applications and imaging modalities, involving the compensation and analysis of physiological organ motion or of tissue changes due to growth or disease patterns. While the original focus of image registration has predominantly been on correcting for rigid-body motion of brain image volumes acquired at different scanning sessions, often with different modalities, the advent of dedicated longitudinal and cross-sectional brain studies soon necessitated the development of more sophisticated methods that are able to detect and measure local structural or functional changes, or group differences. Moving outside of the brain, cine imaging and dynamic imaging required the development of deformable image registration to directly measure or compensate for local tissue motion.
View Article and Find Full Text PDFRectal tumour segmentation in dynamic contrast-enhanced MRI (DCE-MRI) is a challenging task, and an automated and consistent method would be highly desirable to improve the modelling and prediction of patient outcomes from tissue contrast enhancement characteristics - particularly in routine clinical practice. A framework is developed to automate DCE-MRI tumour segmentation, by introducing: perfusion-supervoxels to over-segment and classify DCE-MRI volumes using the dynamic contrast enhancement characteristics; and the pieces-of-parts graphical model, which adds global (anatomic) constraints that further refine the supervoxel components that comprise the tumour. The framework was evaluated on 23 DCE-MRI scans of patients with rectal adenocarcinomas, and achieved a voxelwise area-under the receiver operating characteristic curve (AUC) of 0.
View Article and Find Full Text PDFDiscrete optimisation strategies have a number of advantages over their continuous counterparts for deformable registration of medical images. For example: it is not necessary to compute derivatives of the similarity term; dense sampling of the search space reduces the risk of becoming trapped in local optima; and (in principle) an optimum can be found without resorting to iterative coarse-to-fine warping strategies. However, the large complexity of high-dimensional medical data renders a direct voxel-wise estimation of deformation vectors impractical.
View Article and Find Full Text PDFMed Image Comput Comput Assist Interv
November 2014
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a powerful protocol for assessing tumour progression from changes in tissue contrast enhancement. Manual colorectal tumour delineation is a challenging and time consuming task due to the complex enhancement patterns in the 4D sequence. There is a need for a consistent approach to colorectal tumour segmentation in DCE-MRI and we propose a novel method based on detection of the tumour from signal enhancement characteristics of homogeneous tumour subregions and their neighbourhoods.
View Article and Find Full Text PDFMed Image Comput Comput Assist Interv
November 2014
Medical scans are today routinely acquired using multiple sequences or contrast settings, resulting in multispectral data. For the automatic analysis of this data, the evaluation of multispectral similarity is essential. So far, few concepts have been proposed to deal in a principled way with images containing multiple channels.
View Article and Find Full Text PDFSeveral biomedical applications require accurate image registration that can cope effectively with complex organ deformations. This paper addresses this problem by introducing a generic deformable registration algorithm with a new regularization scheme, which is performed through bilateral filtering of the deformation field. The proposed approach is primarily designed to handle smooth deformations both between and within body structures, and also more challenging deformation discontinuities exhibited by sliding organs.
View Article and Find Full Text PDFMed Image Comput Comput Assist Interv
February 2014
Estimation of physiologically plausible deformations is critical for several medical applications. For example, lung cancer diagnosis and treatment requires accurate image registration which preserves sliding motion in the pleural cavity, and the rigidity of chest bones. This paper addresses these challenges by introducing a novel approach for regularisation of non-linear transformations derived from a bilateral filter.
View Article and Find Full Text PDFMed Image Comput Comput Assist Interv
February 2014
Image-guided interventions often rely on deformable multimodal registration to align pre-treatment and intra-operative scans. There are a number of requirements for automated image registration for this task, such as a robust similarity metric for scans of different modalities with different noise distributions and contrast, an efficient optimisation of the cost function to enable fast registration for this time-sensitive application, and an insensitive choice of registration parameters to avoid delays in practical clinical use. In this work, we build upon the concept of structural image representation for multi-modal similarity.
View Article and Find Full Text PDF