Aseptic loosening remains one of the top causes of revision surgery of total knee arthroplasty (TKA). Radiostereometric analysis (RSA) is used in research to measure implant migration, however limitations prevent its clinical use. New methods have allowed the same measurements as RSA to be performed with computed tomography (CT) scanners (CT-RSA).
View Article and Find Full Text PDFRadiostereometric analysis (RSA) is the current gold standard to determine implant migration, but it requires bone markers and special equipment. Therefore, we developed VoluMetric Matching Micromotion Analysis (V3MA), a software program for Computed Tomography-based radiostereometric analysis (CT-RSA). This study aimed to determine the accuracy and precision of V3MA in vitro compared to RSA and provide a clinical proof of concept.
View Article and Find Full Text PDFThough radiostereometric analysis (RSA) is the gold standard for migration tracking, computed tomography-based RSA (CT-RSA) does not require marker beads and is available for clinical adoption. This study investigated CT-RSA in comparison to RSA for assessing hip implant stability with inducible displacement (ID) examinations. Patients (n = 48) from a previous study returned to be re-examined for femoral stem stability with CT-RSA and RSA imaging.
View Article and Find Full Text PDFIntroduction: The inelasticity of ceramic bearings might affect primary stability and migration of implants in press-fit total hip arthroplasty (THA). This randomised controlled trial compares migration patterns of the uncemented Delta-TT cup and H-MAX S stem between ceramic and polyethylene liners, up to 5 years follow-up.
Methods: Patients receiving primary press-fit THA were randomly allocated to a ceramic ( 28) or polyethylene ( 25) liner.
Aims: The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients.
View Article and Find Full Text PDFBackground: Radiostereometric analysis (RSA) provides highly accurate data about the migration of a total knee arthroplasty (TKA) component. However, patient-reported outcome measures (PROMs) reflect the patients' perspective of their functional status, pain, and overall health after TKA. The aim of this study was to evaluate the association between tibial implant migration and change in postoperative PROMs and clinical scores, using data pooled from long-term follow-up RSA studies.
View Article and Find Full Text PDFOpening remarks: These guidelines are the result of discussions within a diverse group of RSA researchers. They were approved in December 2023 by the board and selected members of the International Radiostereometry Society to update the guidelines by Valstar et al. [1].
View Article and Find Full Text PDFAims: The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) - the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) - using virtual modelling.
Methods: Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients.
Acta Orthop
March 2024
Background And Purpose: Different marker-selection methods are applied to represent implant and tibial segments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of markers throughout subsequent RSA examinations ("consistent-marker method") is used or all available markers at each follow-up ("all-marker method"). The aim of this secondary analysis was to compare marker-selection methods on individual and group level TKA migration results.
View Article and Find Full Text PDFAims: Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
May 2024
Purpose: This clinical fluoroscopy study investigated knee kinematics of two different cemented fixed-bearing, posterior-stabilised (PS) total knee arthroplasty (TKA) designs: an asymmetric tibial component including an asymmetric insert designed to optimise personalised balance and fit and its precursor symmetrical design with symmetric insert.
Methods: A consecutive series of patients (16 TKAs from each treatment group) participating in a randomised controlled trial comparing TKA migration was included. The exclusion criterion was the use of walking aids.
Aims: The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface.
Methods: Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem.
Background: Loosening is a major cause for failure of total hip and total knee arthroplasties (THAs/TKAs). Preemptive diagnostics of asymptomatic loosening could open strategies to prevent gross loosening. A multitude of biomarkers may discriminate between loosened and stable implants, but it is unknown which have the best performance.
View Article and Find Full Text PDFAims: Conflicting clinical results are reported for the ATTUNE Total Knee Arthroplasty (TKA). This randomized controlled trial (RCT) evaluated five-year follow-up results comparing cemented ATTUNE and PFC-Sigma cruciate retaining TKAs, analyzing component migration as measured by radiostereometric analysis (RSA), clinical outcomes, patient-reported outcome measures (PROMs), and radiological outcomes.
Methods: A total of 74 primary TKAs were included in this single-blind RCT.
J Bone Joint Surg Am
November 2023
Background: Three-dimensional (3D) printing of highly porous orthopaedic implants aims to promote better osseointegration, thus preventing aseptic loosening. However, short-term radiostereometric analysis (RSA) after total knee arthroplasty (TKA) has shown higher initial migration of cementless 3D-printed tibial components compared with their cemented counterparts. Therefore, critical evaluation of longer-term tibial component migration is needed.
View Article and Find Full Text PDFThe primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary objectives included clinical outcomes and patient-reported outcome measures (PROMs). A double-blinded, randomized study was conducted including 96 TKAs.
View Article and Find Full Text PDFIntroduction: Dual mobility implants have been successful in reducing postoperative hip dislocation but mid-term results of cup migration and polyethylene wear are missing in the literature. Therefore, we measured migration and wear at 5-year follow-up using radiostereometric analysis (RSA).
Materials And Methods: A cohort of 44 patients (mean age 73, 36 female) with heterogeneous indications for hip arthroplasty but all with a high risk of hip dislocation received total hip replacement (THA) with The Anatomic Dual Mobility X3 monoblock acetabular construct and a highly crosslinked polyethylene liner.
Aims: The primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS) total knee arthroplasty (TKA) designs, two years postoperatively, using radiostereometric analysis (RSA) in order to assess the risk of the development of aseptic loosening. A secondary aim was to compare clinical and patient-reported outcome measures (PROMs) between the designs.
Methods: A total of 61 TKAs were analyzed in this randomized clinical RSA trial.
Radiostereometric analysis can be used for computing movement of a tibial baseplate relative to the tibia (termed migration) to determine stability of fixation. Quantifying migration in six degrees of freedom requires establishing a coordinate system in which to express the movement. Establishing consistent migration directions among patients and baseplate designs remains challenging.
View Article and Find Full Text PDFAims: The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA).
Methods: A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively.
Acta Orthop
April 2022
Background And Purpose: Ceramic liners may reduce early stability of uncemented acetabular components due to higher stiffness. However, the bone ingrowth capacities of porous trabecular titanium might compensate for this effect. This prospective randomized trial quantifies migration patterns of the Delta-TT cup, and compares polyethylene and ceramic liners.
View Article and Find Full Text PDFBackground And Purpose: Dual-mobility hip arthroplasty utilizes a freely rotating polyethylene acetabular liner to protect against dislocation. As liner motion has not been confirmed in vivo, we undertook this using dynamic radiostereometry (RSA).
Patients And Methods: 6 patients with Anatomical Dual Mobility acetabular components were included.
Background And Purpose: In total knee arthroplasty (TKA), metal-backed (MBT) and all-polyethylene (APT) designs have shown comparable implant migration up to 2 years postoperatively using radiostereometric analysis (RSA). However, studies comparing mid-term migration of both designs are lacking. Furthermore, continuously migrating TKAs up to 2 years may continue to migrate or stabilize thereafter.
View Article and Find Full Text PDF