Publications by authors named "Barry O'Connell"

Parasite-released extracellular vesicles (EVs) deliver signals to the host immune system that are critical to maintaining the long-term relationship between parasite and host. In the present study, total EVs (FhEVs) released in vitro by adults of the helminth parasite Fasciola hepatica were isolated using a recently described gravity flow method that protects their structural integrity. The FhEVs molecular cargo was defined using proteomic analysis and their surface topology characterised by glycan microarrays.

View Article and Find Full Text PDF

One of the established limitations of metal additive manufacturing (AM) methods, such as selective laser melting (SLM), is the resulting rough surface finish. Laser polishing is one method that can be used to achieve an improved surface finish on AM printed parts. This study is focused on the laser surface polishing of AM parts using CO₂ laser beam irradiation.

View Article and Find Full Text PDF

A novel poly( N-isopropylacrylamide) (PNIPAM) hydrogel containing different photosensitizers (protoporphyrin IX (PpIX), pheophorbide a (Pba), and protoporphyrin IX dimethyl ester (PpIX-DME)) has been synthesized with a significant improvement in water solubility and potential for PDT applications compared to the individual photosensitizers (PSs). Conjugation of PpIX, Pba, and PpIX-DME to the poly( N-isopropylacrylamide) chain was achieved using the dispersion polymerization method. This study describes how the use of nanohydrogel structures to deliver a photosensitizer with low water solubility and high aggregation tendencies in polar solvents overcomes these limitations.

View Article and Find Full Text PDF

3,5-Diformyl-4,4-difluoro-4-bora-3a,4a-diaza-s-indacene (3,5-diformyl-BODIPY) can be used as an efficient biofunctional cross-linker to generate a new class of chitosan-based hydrogels with fluorescence resonance energy transfer (FRET) dynamics and good solubility in water. The hydrogel was fully characterized by FT-IR, UV-vis, fluorescence, FE-SEM, AFM, rheology and picosecond time-resolved spectroscopic techniques. The self-healing ability was demonstrated by rheological recovery and macroscopic and microscopic observations.

View Article and Find Full Text PDF

The emergence of drug-eluting stents (DES) as a viable replacement for bare metal stenting has led to a significant decrease in the incidence of clinical restenosis. This is due to the transport of anti-restenotic drugs from within the polymer coating of a DES into the artery wall which arrests the cell cycle before restenosis can occur. The efficacy of DES is still under close scrutiny in the medical field as many issues regarding the effectiveness of DES drug transport in vivo still exist.

View Article and Find Full Text PDF

Purpose: In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans.

Methods: The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams.

View Article and Find Full Text PDF

The development and use of drug eluting stents has brought about significant improvements in reducing in-stent restenosis, however, their long term presence in the artery is still under examination due to restenosis reoccurring. Current studies focus mainly on stent design, coatings and deployment techniques but few studies address the issue of the physics of three dimensional mass transport in the artery wall. There is a dearth of adequate validated numerical mass transport models that simulate the physics of diffusion dominated drug transport in the artery wall whilst under compression.

View Article and Find Full Text PDF

Carotid endarterectomy (CEA) is currently accepted as the gold standard for interventional revascularisation of diseased arteries belonging to the carotid bifurcation. Despite the proven efficacy of CEA, great interest has been generated in carotid angioplasty and stenting (CAS) as an alternative to open surgical therapy. CAS is less invasive compared with CEA, and has the potential to successfully treat lesions close to the aortic arch or distal internal carotid artery (ICA).

View Article and Find Full Text PDF

Coronary artery disease can be treated by implanting a stent into the blocked region of an artery, thus enabling blood perfusion to distal vessels. Minimally invasive procedures of this nature often result in damage to the arterial tissue culminating in the re-blocking of the vessel. In an effort to alleviate this phenomenon, known as restenosis, drug eluting stents were developed.

View Article and Find Full Text PDF

The development of restenosis within the coronary arteries after a stenting procedure has been addressed with the development of the drug eluting stent device. However, in recent times the superiority of the drug eluting stent over bare metal stents has been brought into question. A lack of knowledge regarding the behavior of drug transport from the drug eluting devices contributes to this uncertainty.

View Article and Find Full Text PDF

We present modifications to conventional nanoindentation that realize variable temperature, flat punch indentation of ultrathin films. The technique provides generation of large strain, thin film extrusion of precise geometries that idealize the essential flows of nanoimprint lithography, and approximate constant area squeeze flow rheometry performed on thin, macroscopic soft matter samples. Punch radii as small as 185 nm have been realized in ten-to-one confinement ratio testing of 36 nm thick polymer films controllably squeezed in the melt state to a gap width of a few nanometers.

View Article and Find Full Text PDF

The mechanical patterning of thin films has received recent attention due to significant potential for efficient nanostructure fabrication. For solid films, mechanically thinning wide areas remains particularly challenging. In this work, we introduce a new plastic ratchet mechanism involving small amplitude (<10 nm), oscillatory shear motion of the forging die.

View Article and Find Full Text PDF