The Fifth Artificial Pancreas Workshop: Enabling Fully Automation, Access, and Adoption was held at the National Institutes of Health (NIH) Campus in Bethesda, Maryland on May 1 to 2, 2023. The organizing Committee included representatives of NIH, the US Food and Drug Administration (FDA), Diabetes Technology Society, Juvenile Diabetes Research Foundation (JDRF), and the Leona M. and Harry B.

View Article and Find Full Text PDF

Diabetes Technology Society hosted its annual Diabetes Technology Meeting from November 3 to November 5, 2022. Meeting topics included (1) the measurement of glucose, insulin, and ketones; (2) virtual diabetes care; (3) metrics for managing diabetes and predicting outcomes; (4) integration of continuous glucose monitor data into the electronic health record; (5) regulation of diabetes technology; (6) digital health to nudge behavior; (7) estimating carbohydrates; (8) fully automated insulin delivery systems; (9) hypoglycemia; (10) novel insulins; (11) insulin delivery; (12) on-body sensors; (13) continuous glucose monitoring; (14) diabetic foot ulcers; (15) the environmental impact of diabetes technology; and (16) spinal cord stimulation for painful diabetic neuropathy. A live demonstration of a device that can allow for the recycling of used insulin pens was also presented.

View Article and Find Full Text PDF

Diabetes Technology Society hosted its annual Diabetes Technology Meeting on November 4 to November 6, 2021. This meeting brought together speakers to discuss various developments within the field of diabetes technology. Meeting topics included blood glucose monitoring, continuous glucose monitoring, novel sensors, direct-to-consumer telehealth, metrics for glycemia, software for diabetes, regulation of diabetes technology, diabetes data science, artificial pancreas, novel insulins, insulin delivery, skin trauma, metabesity, precision diabetes, diversity in diabetes technology, use of diabetes technology in pregnancy, and green diabetes.

View Article and Find Full Text PDF

Diabetes Technology Society hosted its annual Diabetes Technology Meeting on November 12 to November 14, 2020. This meeting brought together speakers to cover various perspectives about the field of diabetes technology. The meeting topics included artificial intelligence, digital health, telemedicine, glucose monitoring, regulatory trends, metrics for expressing glycemia, pharmaceuticals, automated insulin delivery systems, novel insulins, metrics for diabetes monitoring, and discriminatory aspects of diabetes technology.

View Article and Find Full Text PDF

This is a summary report of the most important aspects discussed during the YSI 2300 Analyzer Replacement Meeting. The aim is to provide the interested reader with an overview of the complex topic and propose solutions for the current issue. This solution should not only be adequate for the United States or Europe markets but also for all other countries.

View Article and Find Full Text PDF
Article Synopsis
  • New digital health software and sensors for diabetes are gaining traction, enabling timely information access for patients and personalized advice from healthcare professionals.
  • The Diabetes Technology Society and Sansum Diabetes Research Institute hosted the 3rd Annual Digital Diabetes Congress to unite stakeholders from various sectors to discuss trends and applications in diabetes technology.
  • The congress covered eight key topics including user experience, clinical aspects, marketing, investment, regulation, data ownership, engagement, and the future of digital health, as outlined in the meeting's session summaries.
View Article and Find Full Text PDF

Insulin pumps are used by a steadily increasing number of patients with diabetes. Avoiding certain disadvantages of conventional pumps (ie, the insulin infusion set) might make pump therapy even more attractive. Patch pumps are usually attached by means of an adhesive layer to the skin and have several additional advantages (smaller, more discrete, easier to use, and cheaper than conventional insulin pumps).

View Article and Find Full Text PDF
Patch Pumps for Insulin.

J Diabetes Sci Technol

January 2019

Newly developed patch pumps are starting to occupy a noticeable fraction of the insulin delivery market. New entrants, using novel technologies, promise accurate, flexible insulin delivery at lower costs. In the section, we review the currently available devices, discuss some of the devices on the horizon, and speculate about some fascinating new approaches.

View Article and Find Full Text PDF

On July 6 and 7, 2016 the Fourth Artificial Pancreas Workshop: Testing and Adoption of Current and Emerging Technologies was held on the National Institutes of Health (NIH) Campus at the Lister Hill Auditorium. The meeting was sponsored by a group of governmental organizations and NGOs, listed in Appendix A. This was a very timely meeting as the artificial pancreas appears to be growing from academic studies to commercial projects.

View Article and Find Full Text PDF

Insulin pens are more accurate and easier to teach than other methods of insulin delivery. They also do not suffer from the risk of mismatch of insulin concentration and type of insulin syringe. The ISO standard used to test insulin pens, however, needs to be updated to reflect their clinical use.

View Article and Find Full Text PDF

With the availability of a smaller mixing pen, mass marketing of less stable medications is possible. Bidureon is one such medication, and the properties of its pen are discussed along with the prospects for future mixing pens.

View Article and Find Full Text PDF

Background: There is a perception that patients with diabetes struggle to produce sufficient blood to fill glucose test strips, including strips with 1-µL fill requirements. The purpose of this study was to determine the volume of blood expressed when these patients perform routine fingersticks using their own lancing device and sampling technique and to evaluate the relationship between blood volume and pain.

Methods: Sixty-four patients (type 1 or type 2 diabetes) performed 8 fingersticks using their own lancing device and preferred depth setting and lancing technique.

View Article and Find Full Text PDF

Self-monitoring of blood glucose provides information about blood glucose control. The data become useful information and knowledge through careful analysis for patterns that are appropriate or can be corrected. Some analyses can be performed on newer blood glucose meters, but most often, this needs to be done on a computer, tablet, or smartphone.

View Article and Find Full Text PDF

The pain associated with lancing can be a significant barrier to self-monitoring of blood glucose (SMBG). The OneTouch® Delica™ lancing device contains features to reduce lancing pain, including improved lancet control and stability, reduced vibration, and a thinner, 33-gauge lancet. This 2-visit, randomized controlled trial assessed perceived pain of lancing with the OneTouch® Delica™ compared with 4 other common lancing devices: OneTouch® Comfort™, ACCU-CHEK® Softclix, ACCU-CHEK® Multiclix, and Ascensia® Microlet™2.

View Article and Find Full Text PDF

Background: This study compared insulin lispro (IL) pharmacokinetics (PK) and pharmacodynamics (PD) delivered via microneedle intradermal (ID) injection with subcutaneous (SC) injection under euglycemic glucose clamp conditions.

Methods: Ten healthy male volunteers were administered 10 international units (IU) of IL at 3 microneedle lengths (1.25, 1.

View Article and Find Full Text PDF

Regulatory interest has focused on the accuracy of blood glucose monitoring systems. Currently, almost all systems meet the International Organization for Standardization (ISO) 15197 clinical standard (≥95% of the values within 20% of the reference for values above 75 mg/dl and within 15 mg/dl below that level). Should the systems have to meet one of the extended ISO standards of 15%, 10%, or even 5%? There is a wide variety of people with diabetes doing glucose monitoring, and the majority do not need better accuracy.

View Article and Find Full Text PDF

Glucose monitoring has become an integral part of diabetes care but has some limitations in accuracy. Accuracy may be limited due to strip manufacturing variances, strip storage, and aging. They may also be due to limitations on the environment such as temperature or altitude or to patient factors such as improper coding, incorrect hand washing, altered hematocrit, or naturally occurring interfering substances.

View Article and Find Full Text PDF

Current clinical guidelines for diabetes care encourage self-monitoring of blood glucose (SMBG) to improve glycemic control. Specific protocols remain variable, however, particularly among non-insulin-using patients. This is due in part to efficacy studies that neglect to consider (1) the performance of monitoring equipment under real-world conditions, (2) whether or how patients have been taught to take action on test results, and (3) the physiological, behavioral, and social circumstances in which SMBG is carried out.

View Article and Find Full Text PDF

Most blood glucose monitoring systems need coding to correct for variation in lots of enzyme, which leads to differences in lots of strips. About 16% of patients miscode the meters, although the magnitude of the miscoding is unstudied. This miscoding has the potential to cause errors as high as 30% and to cause errors in adjusting insulin therapy that could lead to hypoglycemia at least 10% of the time.

View Article and Find Full Text PDF

Objective: This study was done to evaluate the accuracy and safety of measuring glucose with the GlucoWatch biographer in children and adolescents with diabetes.

Methods: Accuracy was assessed by comparing biographer glucose measurements with hourly blood glucose measurements using the HemoCue (Aktiebolaget Leo, Helsingborg, Sweden) Photometer for up to 12 h of monitoring. Safety was evaluated by examining the biographer application sites immediately upon removal of the devices, and then at regular intervals.

View Article and Find Full Text PDF