Publications by authors named "Barry Belanger"

Three-dimensional cardiac mapping is important for optimal visualization of the heart during cardiac ablation for the treatment of certain arrhythmias. However, many hospitals and clinics worldwide cannot afford the high cost of the current mapping systems. We set out to determine if, using predefined algorithms, comparable 3D cardiac maps could be created by a new device that relies on data generated from single-plane fluoroscopy and patient recording and monitoring systems, without the need for costly equipment, infrastructure changes, or specialized catheters.

View Article and Find Full Text PDF

Dynamic motion of the heart due to cardiac and respiratory cycles, and rotation from varying patient positions between imaging modalities, can cause errors during cardiac image registration. This study used phantom, patient and animal models to assess and correct these errors. Rotational errors were identified and corrected using different phantom orientations.

View Article and Find Full Text PDF

The current x-ray source trajectory for C-arm based cone-beam CT is a single arc. Reconstruction from data acquired with this trajectory yields cone-beam artifacts for regions other than the central slice. In this work we present the preliminary evaluation of reconstruction from a source trajectory of two concentric arcs using a flat-panel detector equipped C-arm gantry (GE Healthcare Innova 4100 system, Waukesha, Wisconsin).

View Article and Find Full Text PDF

In this article, we present GE Healthcare's design philosophy and implementation of X-ray imaging systems with dose management for pediatric patients, as embodied in its current radiography and fluoroscopy and interventional cardiovascular X-ray product offerings. First, we present a basic framework of image quality and dose in the context of a cost-benefit trade-off, with the development of the concept of imaging dose efficiency. A set of key metrics of image quality and dose efficiency is presented, including X-ray source efficiency, detector quantum efficiency (DQE), detector dynamic range, and temporal response, with an explanation of the clinical relevance of each.

View Article and Find Full Text PDF

Background: Anatomic structures such as the left atrium and the pulmonary veins (PVs) are not delineated by fluoroscopy because there is no contrast differentiation between them and the surrounding anatomy. Representation of an anatomic structure via a 3D model obtained from computed tomography (CT) imaging and subsequent projection of these images over the fluoroscopy system may help in navigation of the mapping and ablation catheter to the appropriate sites during electrophysiology procedures.

Methods And Results: In this feasibility study, in vitro experiments were performed with a plastic heart model (phantom) with 2 catheters or radiopaque platinum beads placed in the phantom at the time of CT imaging and fluoroscopy.

View Article and Find Full Text PDF