Estimation of the right ventricular systolic pressure (RVSP) using echocardiographically derived maximal instantaneous gradient across the ventricular septal defect is a well-utilized tool, which can potentially underestimate the RVSP in patients with conduction abnormalities as such its utility in these patients is questionable.
View Article and Find Full Text PDFObjective: Assess clinical performance of a new device for transcatheter closure of atrial septal defect (ASD).
Background: Previously-approved ASD Closure devices have known limitations. Device erosion has been associated with the AMPLATZER® septal occluder in patients with retro-aortic rim deficiency (<5 mm), while defects ≥18 mm are too large for the GORE® CARDIOFORM septal occluder.
Patients with the Marfan syndrome (MFS) are at risk for sudden death. The contribution of arrhythmias is unclear. This study examines the prevalence of arrhythmias in children with the MFS and their relation to clinical and/or echocardiographic factors.
View Article and Find Full Text PDFPacing Clin Electrophysiol
July 2017
Background: Ablation within the aortic cusp is safe and effective in adults. There are little data on aortic cusp ablation in the pediatric literature. We investigated the safety and efficacy of aortic cusp ablation in young patients.
View Article and Find Full Text PDFCurrent practice of sedation and anesthesia for patients undergoing pediatric and congenital cardiac catheterization laboratory (PCCCL) procedures is known to vary among institutions, a multi-society expert panel with representatives from the Congenital Heart Disease Council of the Society for Cardiovascular Angiography and Interventions, the Society for Pediatric Anesthesia and the Congenital Cardiac Anesthesia Society was convened to evaluate the types of sedation and personnel necessary for procedures performed in the PCCCL. The goal of this panel was to provide practitioners and institutions performing these procedures with guidance consistent with national standards and to provide clinicians and institutions with consensus-based recommendations and the supporting references to encourage their application in quality improvement programs. Recommendations can neither encompass all clinical circumstances nor replace the judgment of individual clinicians in the management of each patient.
View Article and Find Full Text PDFObjectives: Assess impact of malattached septum primum (MASP) on transcatheter closure of interatrial communications.
Background: Large defect size and deficient rims have been described as predictors for complications and unsuccessful device placement in closure of interatrial communications. MASP is an underappreciated morphologic atrial septal variation whose prevalence in isolated atrial communications and its influence on percutaneous device closure has not been systematically assessed.
Isolated peripheral pulmonary artery stenosis presenting in adulthood is an uncommon cause of right ventricular hypertension and may be misdiagnosed as primary or thromboembolic pulmonary hypertension. Treatment consists of balloon angioplasty and stenting of the affected vessels, although the procedure can be complicated by reperfusion pulmonary edema.
View Article and Find Full Text PDFThe hemodynamics of isolated large ventricular septal defect with an intact atrial septum results in greater mitral valve (MV) annular dilation and an increased incidence of mitral regurgitation (MR). MR will resolve in most patients after surgical VSD closure alone without MV repair.
View Article and Find Full Text PDFBackground: Catheter ablation of left-sided atrial arrhythmias generally is performed using a transfemoral venous approach through the inferior vena cava (IVC). In this report, we assessed the feasibility of a percutaneous transhepatic approach to ablation of left-sided atrial arrhythmias in 2 patients with interruption of the IVC.
Methods And Results: Patient 1 had atrial flutter in the setting of complex congenital heart disease and prior Fontan for univentricular physiology and a single atrium.
We report a case of a 68-year-old woman with a basal postmyocardial infarction ventricular septal defect that recurred 4 months after initial surgical repair. Successful transcatheter closure using an Amplatzer Muscular VSD Occluder was facilitated by direct percutaneous left ventricular access.
View Article and Find Full Text PDFHemodynamically significant perivalvular regurgitation affects about 1.5% of all prosthetic valve implants. Reoperation carries increased risk--especially in the setting of concomitant comorbidities of left ventricular dysfunction, prior coronary artery bypass grafts, renal dysfunction, and advanced age.
View Article and Find Full Text PDFA 3-year-old girl with Alport syndrome presented with decompensated heart failure from hypertension-induced cardiomyopathy 6 months following renal biopsy. Selective renal angiography revealed a large left renal arteriovenous fistula (AVF) with poor perfusion to the left renal parenchyma. The AVF was treated by transcatheter embolization using an Amplatzer vascular plug.
View Article and Find Full Text PDFAtrial-level repair for transposition of the great arteries is one of the greatest achievements of modern cardiovascular medicine, transforming a once fatal congenital heart condition into one with excellent long-term survival. Although atrial-level repair has been supplanted by the arterial switch, there remains a population of patients who underwent atrial-level repair as children and now require ongoing care as adults. Survival slowly continues to decline in this population mainly owing to systemic right ventricular dysfunction and sudden death.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
June 2008
Pulmonary arteriovenous malformations (PAVMs) are a relatively uncommon but potentially life-threatening condition manifested by cyanosis, paradoxical embolization, brain abscess, and rupture. A variety of transcatheter closure devices have been used to occlude PAVMs however risks of device embolization, incomplete closure, or large delivery systems have made each of these methods sub-optimal. The Amplatzer Vascular Plug II (AVP II) is a new multisegmented, woven nitinol cylinder that can be deployed through a small delivery catheter.
View Article and Find Full Text PDFNat Clin Pract Cardiovasc Med
August 2007
Background: A 51-year-old woman with a 5-year history of metastatic small bowel carcinoid disease developed fatigue and gradually worsening dyspnea on exertion, over 6 months.
Investigations: Physical examination, transthoracic and transesophageal echocardiography, and aortography.
Diagnosis: Left-sided carcinoid disease associated with a patent foramen ovale.