Aims: Women are less likely to receive lipid-lowering therapy (LLT) after acute myocardial infarction (AMI). We analysed whether this under-prescription currently persists and has an impact on long-term outcomes.
Methods And Results: The FAST-MI programme consists of nationwide registries including all patients admitted for AMI ≤ 48 h from onset over a 1 month period in 2005, 2010, and 2015, with long-term follow-up.
Importance: Currently there is no standard therapy to improve cancer-related anorexia, hampering survival. Mirtazapine has been suggested as a feasible option in this context.
Objectives: To assess the effect of mirtazapine on appetite and energy consumption in patients with advanced non-small cell lung cancer (NSCLC).
Aims: Unprotected left main coronary artery (ULMCA) occlusion is a rare and disastrous condition with scarce data on presentation and outcomes. Herein, we report data on patients presenting with acute coronary syndrome due to ULMCA occlusion at four different institutions.
Methods: This is an international multicentre observational study.
Introduction: Leptospirosis is a neglected zoonotic disease, affecting mainly poor and vulnerable populations.
Methodology: A cross sectional-study was carried out in 557 subjects from Olavarría county (Argentina) to estimate the seroprevalence of leptospirosis and the factors associated with seropositivity. A survey was carried out to obtain clinical and epidemiological data.
Background: Improvements in drug-eluting stent design have led to a reduced frequency of repeat revascularisation and new biodegradable polymer coatings may allow a shorter duration of dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI).
Aims: The Improved Drug-Eluting stent for All-comers Left Main (IDEAL-LM) study aims to investigate long-term clinical outcomes after implantation of a biodegradable polymer platinum-chromium everolimus-eluting stent (BP-PtCr-EES) followed by 4 months DAPT compared to a durable polymer cobalt-chromium everolimus-eluting stent (DP-CoCr-EES) followed by 12 months DAPT in patients undergoing PCI of unprotected left main coronary artery (LMCA) disease.
Methods: This is a multicentre randomised clinical trial study in patients with an indication for coronary artery revascularisation who have been accepted for PCI for LMCA disease after Heart Team consultation.
Novel pharmacologic treatment options reduce mortality and morbidity in a cost-effective manner in patients with heart failure (HF). Undisputedly, the effective implementation of these agents is an essential element of good clinical practice, which is endorsed by the European Society of Cardiology (ESC) guidelines on acute and chronic HF. Yet, physicians struggle to implement these therapies as they have to balance the true and/or perceived risks versus their substantial benefits in clinical practice.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
January 2022
Calcified aortic stenoses are among the most prevalent form of cardiovascular diseases in the industrialized countries. This progressive disease, with no effective medical therapy, ultimately requires aortic valve replacement - either a surgical or very recently transcatheter aortic valve implantation. Increase leaflet mechanical stress is one of the main determinants of the structural deterioration of bioprosthetic aortic valves.
View Article and Find Full Text PDFFor the last two decades, various degradable stents have been proposed to treat coronary artery diseases and replace metallic stents to avoid residual foreign material after healing. To date, the right balance between suitable scaffolding and loss of radial strength soon after endothelium restoration is still an unmet need. The present article reports on the First-in-Man trial of a drug-free bioresorbable stent based on a lactic acid stereocopolymer composed of 98% l-lactyl units selected to release stress shielding earlier than in the case of homopoly(l-lactic acid).
View Article and Find Full Text PDFTranscatheter aortic valve (TAV) replacement has become a viable alternative to surgery for high and intermediate risk patients with severe aortic stenosis. This technology may extend to the younger and lower risk patients. In this population, long-term durability of the TAV is key.
View Article and Find Full Text PDFAn original in vitro/in silico method was developed to estimate the local and global mechanical stress applied on the bioprosthetic valve leaflet, which can be important for better understanding of the valve durability. A non-contact system based on stereophotogammetry and digital image correlation enabled filming and studying the valve leaflet movement frame by frame and performing three-dimensional analysis. The deformation was applied in a finite element model in order to calculate the local mechanical stress applied.
View Article and Find Full Text PDFObjectives: The authors aimed to compare long-term data of an ultrathin cobalt-chromium stent with passive silicon carbide coating and an active biodegradable polymer that releases sirolimus (O-SES) (Orsiro, BIOTRONIK, Bülach, Switzerland) with the durable polymer-based Xience Prime everolimus-eluting stent (X-EES) (Abbott Vascular, Santa Clara, California).
Background: Biodegradable polymer stents have been developed aiming to overcome long-term detrimental effects of durable polymer stents, ultimately leaving a bare-metal stent in the vessel.
Methods: This multicenter, assessor-blinded trial randomized 452 patients with 505 lesions to either O-SES or X-EES in a 2:1 fashion.
Aims: The valve-in-valve (ViV) procedure has become a valuable alternative for the treatment of failed surgical bioprostheses (BP) in high-risk patients. However, in small BP, the clinical outcomes have been suboptimal due to high post-procedural gradients. We aimed to examine the effect of size and position of the self-expanding transcatheter heart valve (THV) CoreValve on the haemodynamics of ViV within small BP.
View Article and Find Full Text PDFBackground: Although previous observational studies have documented late luminal enlargement and expansive remodeling following implantation of a bioresorbable vascular scaffold (BVS), no comparison with metallic stents has been conducted in a randomized fashion.
Objectives: This study sought to compare vessel remodeling patterns after either Absorb BVS or Xience metallic drug-eluting stent (DES) implantation (Abbott Vascular, Santa Clara, California) and determine the independent predictors of remodeling.
Methods: In the ABSORB II randomized trial, 383 lesions (n = 359) were investigated by intravenous ultrasound both post-procedure and at 3-year follow-up.
Objectives: The aim of this study was to test the hypothesis that 6-month dual antiplatelet therapy (DAPT) is noninferior to 24-month DAPT in aspirin-sensitive patients.
Background: The ITALIC (Is There a Life for DES After Discontinuation of Clopidogrel) trial showed that rates of bleeding and thrombotic events at 1 year were much the same with 6 versus 12 months of DAPT after percutaneous coronary intervention with second-generation drug-eluting stents. In this report, 2-year follow-up is presented.
Background: Continuous improvements in stent technology make percutaneous coronary intervention (PCI) a potential alternative to surgery in selected patients with unprotected left main coronary artery (uLMCA) disease. The optimal duration of dual antiplatelet therapy (DAPT) in these patients remains undetermined, and in addition, new stent designs using a bioabsorbable polymer might allow shorter duration of DAPT.
Study Design: IDEAL-LM is a prospective, randomized, multicenter study that will enroll 818 patients undergoing uLMCA PCI.
J Environ Sci (China)
February 2017
Objectives: The study compared, by intravascular ultrasound (IVUS), acute gain (AG) at the site of the pre-procedural minimal lumen area (MLA) achieved by either the Absorb (Abbott Vascular, Santa Clara, California) scaffold or the Xience stent and identified the factors contributing to the acute performance of these devices.
Background: It is warranted that the acute performance of Absorb matches that of metallic stents; however, concern exists about acute expansion and lumen gain with the use of Absorb.
Methods: Of a total of 501 patients (546 lesions) in the ABSORB II (ABSORB II Randomized Controlled Trial) randomized trial, 445 patients with 480 lesions were investigated by IVUS pre- and post-procedure.
Background: Data about paclitaxel-eluting balloon (PCB) angioplasty to treat drug-eluting stents (DES) in-stent restenosis (ISR) were mainly collected in selected patient populations in the setting of randomized trials. The main goal of this prospective registry was to confirm the positive findings of these studies in an unselected population in clinical practice.
Methods: Consecutive patients with DES-ISR treated by PCB angioplasty were recruited in this prospective real-world registry.
Background: Experimental and clinical evidence suggests that cyclosporine may attenuate reperfusion injury and reduce myocardial infarct size. We aimed to test whether cyclosporine would improve clinical outcomes and prevent adverse left ventricular remodeling.
Methods: In a multicenter, double-blind, randomized trial, we assigned 970 patients with an acute anterior ST-segment elevation myocardial infarction (STEMI) who were undergoing percutaneous coronary intervention (PCI) within 12 hours after symptom onset and who had complete occlusion of the culprit coronary artery to receive a bolus injection of cyclosporine (administered intravenously at a dose of 2.
Background: Both acute myocardial ischemia and reperfusion contribute to cardiomyocyte death in ST-elevation myocardial infarction (STEMI). The final infarct size is the principal determinant of subsequent clinical outcome in STEMI patients. In a proof-of-concept phase II trial, the administration of cyclosporine prior to primary percutaneous coronary intervention (PPCI) has been associated with a reduction of infarct size in STEMI patients.
View Article and Find Full Text PDFBackground: Biodegradable polymers for release of antiproliferative drugs from drug-eluting stents aim to improve vascular healing. We assessed noninferiority of a novel ultrathin strut drug-eluting stent releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) compared with the durable polymer Xience Prime everolimus-eluting stent (X-EES) in terms of the primary end point in-stent late lumen loss at 9 months.
Methods And Results: A total of 452 patients were randomly assigned 2:1 to treatment with O-SES (298 patients, 332 lesions) or X-EES (154 patients, 173 lesions) in a multicenter, noninferiority trial.
Background: The currently recommended duration of dual antiplatelet therapy (DAPT) in drug-eluting stent (DES) recipients is 12 months to reduce the risk of late stent thrombosis, particularly in those with acute coronary syndrome (ACS).
Objectives: This study hypothesized that antiplatelet treatment with DAPT for 6 months may be noninferior to 24-month DAPT in aspirin-sensitive patients.
Methods: A multicenter, randomized study assigned patients undergoing implantation of everolimus-eluting stents with confirmed nonresistance to aspirin to receive 6- or 24-month DAPT.
The energetics and structure of small HeNI2 clusters are analyzed as the size of the system changes, with N up to 38. The full interaction between the I2 molecule and the He atoms is based on analytical ab initio He-I2 potentials plus the He-He interaction, obtained from first-principle calculations. The most stable structures, as a function of the number of solvent He atoms, are obtained by employing an evolutionary algorithm and compared with CCSD(T) and MP2 ab initio computations.
View Article and Find Full Text PDFAims: The aim of this study was to characterise the coronary stent longitudinal resistance of new coronary stents under worst case clinical crossing simulated configurations.
Methods And Results: Six coronary balloon-expandable stents were evaluated using two different tests. The first was a direct parallel plates longitudinal crush resistance test: it was conducted on stents deployed to 3 mm diameter, and three samples of each model were used.