Publications by authors named "Baltov A"

Background: This retrospective clinical study aims to compare the functional and radiological outcomes after open reduction and internal fixation versus minimally invasive plate osteosynthesis of unstable proximal humerus fractures treated with both locking plate and intramedullary graft.

Methods: Forty-seven patients with proximal humerus fractures were treated with either open reduction and internal fixation (25 cases) or minimally invasive plate osteosynthesis (22 cases) and evaluated retrospectively with a minimum follow-up of 12 months. Thirty-one fresh-frozen fibulae and 16 lyophilized tibia allografts were used for augmentation.

View Article and Find Full Text PDF

: Unstable proximal humerus fractures (PHFs) with metaphyseal defects-weakening the osteosynthesis construct-are challenging to treat. A new augmentation technique of plated complex PHFs with metaphyseal defects was recently introduced in the clinical practice. This biomechanical study aimed to analyze the stability of plated unstable PHFs augmented via implementation of this technique versus no augmentation.

View Article and Find Full Text PDF

Bilateral posterior fracture-dislocation of the shoulders is a very rare entity with an average rate of 0.6/100000 per year. It was first described in 1902 by Mynter.

View Article and Find Full Text PDF

Background: Coronoid fractures frequently occur as part of complex elbow injuries and account for 2%-15% of the cases with dislocations. Comminuted fractures and nonunions necessitate surgical treatment. Considering the latest technological advancements, the aim of this study was to investigate the fixation strength of coronoid replacement using an individualized 3D printed prosthesis with curved cemented intramedullary (IM) stem vs.

View Article and Find Full Text PDF

: The treatment of proximal humerus fractures in elderly patients is challenging, with reported high complication rates mostly related to implant failure involving screw cut-out and penetration. Metaphyseal defects are common in osteoporotic bone and weaken the osteosynthesis construct. A novel technique for augmentation with polymethylmethacrylate (PMMA) bone cement was developed for the treatment of patients in advanced age with complex proximal humerus fractures and metaphyseal voids, whereby the cement was allowed to partially cure for 5-7 min after mixing to achieve medium viscosity, and then it was manually placed into the defect through the traumatic lateral window with a volume of 4-6 mL per patient.

View Article and Find Full Text PDF

Treatment of comminuted intraarticular calcaneal fractures remains controversial and challenging. The aim of this study was to investigate the biomechanical performance of three different methods for fixation of such fractures. Comminuted calcaneal fractures, including Sanders III AB fracture of the posterior facet and Kinner II B fracture of the calcaneocuboid joint (CCJ) articular calcaneal surface, were created in 18 human cadaveric lower legs by osteotomizing.

View Article and Find Full Text PDF

Complex intraarticular distal radius fractures (DRFs), commonly managed with volar locking plates, are challenging. Combined volar and dorsal plating is frequently applied for treatment, however, biomechanical investigations are scant. The aim of this biomechanical study was to investigate volar plating versus double plating in DRFs with different degrees of lunate facet comminution.

View Article and Find Full Text PDF

Background: Displaced midshaft fractures are the most common surgically treated clavicle fractures. However, they are associated with high complication rates following plating due to fixation failure in terms of plate breakage, screw breakage and/or screw loosening. The aim of this study was to compare the biomechanical competence of three different plating techniques for fixation of displaced midshaft clavicle fractures.

View Article and Find Full Text PDF

Objectives: To investigate the biomechanical competence of locked plating augmented with supplemental intramedullary graft in comparison to conventional locked plate fixation in proximal humerus fractures (PHF).

Methods: Complex four-part PHFs were set in 30 artificial humeri assigned to 3 study groups (n = 10 in each group). Group 1 was characterized by loss of medial support, group 2 by simulated severe cancellous bone damage due to osteoporosis, and group 3 by combination of the 2 features.

View Article and Find Full Text PDF

Treatment of complex osteoporotic distal femur fractures with the Less Invasive Stabilization System (LISS) has been associated with high complication rates. The aim of this study was to investigate the biomechanical competence of two different techniques of augmented versus conventional LISS plating. Unstable distal femoral fracture AO/OTA 33-A3 was created via osteotomies in artificial femora simulating osteoporotic bone.

View Article and Find Full Text PDF

Background: This article summarizes the outcome from an international consensus meeting, which took place in Vienna on 4 November 2014.

Scope: The aim of the meeting was to provide the state of the art on the pathophysiology and treatment of acute pain with special emphasis on nimesulide, a non-steroidal anti-inflammatory drug (NSAID) indicated for the treatment of acute pain and primary dysmenorrhea. Besides the data on the mechanisms of acute inflammatory pain and on the efficacy and safety of nimesulide in patients affected by different forms of acute pain, the clinical experience of attending experts was discussed based on selected case reports.

View Article and Find Full Text PDF

Introduction: IM nails have gained popularity for stabilization of humeral shaft fractures (HSF). The initial enthusiasm was tempered by a number of specific complications and thus indications need to be re-evaluated.

Patients And Methods: This retrospective study includes 111 patients with HSF subjected to a treatment protocol of IM fixation with first and second generation of humeral nails.

View Article and Find Full Text PDF