Publications by authors named "Bajo-Rubio M"

Article Synopsis
  • The concept of adequacy in peritoneal dialysis has evolved from focusing mainly on specific goals like solute clearance to prioritizing the overall quality of life for patients.
  • This document aims to provide updated recommendations regarding peritoneal dialysis adequacy, covering key areas such as residual kidney function and different types of dialysis methods.
  • A systematic approach (GRADE) was employed to highlight the quality of evidence for recommendations, and the document references a recent guide by experts from the International Society of Peritoneal Dialysis for additional support.
View Article and Find Full Text PDF

Traditionally, dialysis adequacy has been assessed primarily by determining the clearance of a single small solute, urea. Nevertheless, it has become increasingly evident that numerous other factors play a crucial role in the overall well-being, outcomes and quality of life of dialysis patients. Consequently, in recent years, there has been a notable paradigm shift in guidelines and recommendations regarding dialysis adequacy.

View Article and Find Full Text PDF

Uremic pruritus (UP) is one of the most uncomfortable symptoms for patients in dialysis. UP has a great impact on dialysis patients' quality of life and has a great prevalence between those (28-70%). Physiopathology of UP is unknown and usually is unnoticed for most nephrologists (in more than 65% of centers is underdiagnosed).

View Article and Find Full Text PDF

Clinical application of continuous flow peritoneal dialysis (CFPD) has been explored since the 1960s, but despite anticipated clinical benefits, CFPD has failed to gain a foothold in clinical practice, among others due to the typical use of two catheters (or a dual-lumen catheter) and large dialysate volumes required per treatment. Novel systems applying CFPD via the existing single-lumen catheter using rapid dialysate cycling may solve one of these hurdles. Novel on-demand peritoneal dialysate generation systems and sorbent-based peritoneal dialysate regeneration systems may considerably reduce the storage space for peritoneal dialysate and/or the required dialysate volume.

View Article and Find Full Text PDF

Home hemodialysis (HHD) with low-flow dialysate devices has gained popularity in recent years due to its simple design, portability, and ability to provide greater freedom of movement for our patients. However, there are doubts about the adequacy that this technology offers, since it uses monitors with low-flow bath and lactate. The aim of this study was to demonstrate the clinical benefits of low-flow HHD with the NxStage System One® recently introduced in Spain.

View Article and Find Full Text PDF

A major challenge for the development of a wearable artificial kidney (WAK) is the removal of urea from the spent dialysate, as urea is the waste solute with the highest daily molar production and is difficult to adsorb. Here we present results on glucose degradation products (GDPs) formed during electrooxidation (EO), a technique that applies a current to the dialysate to convert urea into nitrogen, carbon dioxide, and hydrogen gas. Uremic plasma and peritoneal effluent were dialyzed for 8 hours with a WAK with and without EO-based dialysate regeneration.

View Article and Find Full Text PDF

Uremic pruritus (UP) is one of the most uncomfortable symptoms for patients in dialysis. UP has a great impact on dialysis patients' quality of life and has a great prevalence between those (28-70%). Physiopathology of UP is unknown and usually is unnoticed for most nephrologists (in more than 65% of centers is underdiagnosed).

View Article and Find Full Text PDF

A system for sorbent-assisted peritoneal dialysis (SAPD) has been developed that continuously recirculates dialysate via a tidal mode using a single-lumen peritoneal catheter with the regeneration of spent dialysate by means of sorbents. SAPD treatment may improve plasma clearance by the maintenance of a high plasma-to-dialysate concentration gradient and by increasing the mass transfer area coefficient (MTAC) of solutes. The system is designed for daily 8-hr treatment (12 kg, nighttime system).

View Article and Find Full Text PDF

Patients with chronic kidney disease have a higher risk of fractures than the general population due to the added factor of uraemia. Although the mechanisms behind uraemia-associated fractures are not fully understood, it is widely accepted that the decrease in bone mineral content and alteration in bone architecture both increase bone fragility. As chronic kidney disease progresses, the risk of fracture increases, especially once the patient requires dialysis.

View Article and Find Full Text PDF

A system for sorbent-assisted peritoneal dialysis (SAPD) was designed to continuously recirculate dialysate via a tidal mode using a single lumen peritoneal catheter with regeneration of spent dialysate by means of sorbent technology. We hypothesize that SAPD treatment will maintain a high plasma-to-dialysate concentration gradient and increase the mass transfer area coefficient of solutes. Thereby, the SAPD system may enhance clearance while reducing the number of exchanges.

View Article and Find Full Text PDF

Transition is an intrinsic process in the life of a patient with kidney disease and should be planned and anticipated when possible. A single therapy option might not be adequate across a patient's entire lifespan and many patients will require a switch in their treatment modality to adapt the treatment to their clinical and psychosocial needs. There are several reasons behind changing a patient's treatment modality, and the consequences of each decision should be evaluated, considering both short- and long-term benefits and risks.

View Article and Find Full Text PDF

Introduction: Protein-energy wasting (PEW) is associated with increased mortality and differs depending on the chronic kidney disease (CKD) stage and the dialysis technique. The prevalence in non-dialysis patients is understudied and ranges from 0 to 40.8%.

View Article and Find Full Text PDF

Background: The prevalence of subclinical atherosclerosis and the main predictors of progression of this condition in patients undergoing peritoneal dialysis (PD) have been insufficiently investigated.

Objectives And Method: Following a prospective, multicenter, observational design, we studied 237 patients who were treated with PD for ≥3 months, without any clinical background of cardiovascular (CV) disease. Our objectives were the following: (1) to investigate the prevalence of subclinical atherosclerosis, as compared to a control group of age- and sex-matched healthy individuals, and (2) to disclose PD technique-related predictors of progression of disease during a 24-month follow-up period.

View Article and Find Full Text PDF

Introduction: Peritoneal dialysis (PD) is an established renal replacement therapy technique which thanks to the technological and clinical advances has improved its survival rates in recent years.

Objectives: The aim of this study was to evaluate patient and technique survival in PD over 30 years, according to the different decades in order to consolidate its usefulness in healthcare.

Method: Retrospective cohort study including all patients in the PD programme of the Hospital Universitario La Paz (Madrid), from 1980 to 2010.

View Article and Find Full Text PDF

Encapsulating peritoneal sclerosis (EPS) represents a rare complication in peritoneal dialysis (PD) with high mortality. It is characterised by diffuse peritoneal membrane fibrosis, which develops into encapsulation and manifests as clinical signs and symptoms of intestinal obstruction. Its incidence varies from 0.

View Article and Find Full Text PDF

Peritoneal dialysis is a treatment alternative in patients with advanced chronic kidney disease. The infusion of liquid into the peritoneal cavity leads to an increase in intra-abdominal pressure, which can sometimes produce leaks to the chest, giving rise to pleuroperitoneal communication. This is not a common complication, but it brings about high drop-out rates among patients using the technique.

View Article and Find Full Text PDF

Introduction: The use of solutions containing hypertonic glucose (3.86%/4.25%) has been postulated as the method of choice for study the peritoneal function, and permits a better evaluation of the ultrafiltration (UF) capacity.

View Article and Find Full Text PDF