Publications by authors named "Baifang Zeng"

The aim of this study was to evaluate the biomechanical and osseointegrative properties of 3D printed porous PEEK materials loaded with strontium (Sr) and alendronate (ALN), which prepared porous cylindrical material by a fused deposition molding process, coated with Sr and ALN by hydrothermal reaction and dopamine assistance. According to the different coating materials, it could be divided into the PEEK group, PEEK-ALN group, PEEK-Sr group and PEEK-ALN-Sr group. After completing the mechanical analyses, the materials were implanted into the femoral condyles of New Zealand rabbits and the osteogenic capacity of the bracket materials was assessed by Micro-CT scanning, histology and fluorescence staining.

View Article and Find Full Text PDF

Background: This study aims to conduct a finite element analysis (FEA) to assess the bio-mechanical properties of C2 sagittal-parallel pedicle screw (PPS) in fixation for atlantoaxial instability, thereby providing a theoretical foundation for its clinical application.

Methods: A total of 5 intact C1-2 finite element models were established. Based on this, instability models were developed and two different fixation methods were applied for each model: C1 lateral mass screw (LMS) combined with C2 sagittal-parallel pedicle screw (C1LMS + C2PPS), and C1 lateral mass screw combined with C2 traditional pedicle screw (C1LMS + C2PS).

View Article and Find Full Text PDF

Objective: Posterior pelvic ring sacroiliac screws are preferred by clinicians for their good biomechanical performance. However, there are few studies on mechanical analysis and intraoperative screw insertion of the dysplastic sacrum and sacroiliac screw. This study investigated the biomechanical performance of oblique sacroiliac screws (OSS) in S1 combined with transiliac-transsacral screws (TTSs) in S2 for pelvic fracture or sacroiliac dislocation with dysplastic sacrum and evaluated the safety of screw placement assisted by the navigation template.

View Article and Find Full Text PDF

Objective: For pelvic ring fractures, screw fixation became a popular technique for its good biomechanical performance. The safe insertion of anterograde the transpubic screw is important for patients with anterior pelvic ring fractures. This paper is to research the anatomical parameters of the anterograde transpubic screw corridor and evaluate the safety of anterograde transpubic screw placement assisted by the assembled navigation template.

View Article and Find Full Text PDF

Objective: C2 pedicle screw insertion is very important in posterior upper cervical surgery. The traditional screw placement technique requires us to consider both medial inclination and cephalad angle, it is difficult to operate intraoperatively. This paper is to explore a novel method of C2 pedicle screw placement compared with traditional C2 pedicle screw.

View Article and Find Full Text PDF

The objective of this study as to evaluate the biomechanical and osteointegration properties of 3D printed porous polyetheretherketone (PEEK) with hydroxyapatite (HA) coating by simulated body fluid (SBF) method. Cylindrical scaffolds were designed and fabricated by using PEEK material through fused deposition molding (FDM). The scaffolds were divided into solid group, porous group and porous-HA group (decorated by hydroxyapatite).

View Article and Find Full Text PDF

Study Design: A 3D-CT Study.

Objective: To research the feasibility and advantages of screw corridors parallel to the sagittal plane (SPC) of the C2 for transpedicular fixation.

Summary Of Background Data: A total of 125 patients were enrolled for analysis, and the 3D model of the C2 for the 125 patients were reconstructed and analyzed.

View Article and Find Full Text PDF

During the surgical resection and reconstruction of a pathological femoral fracture, the removal of the femoral tumor leaves a large bone defect. Thus, it is necessary to reconstruct the defect and perform internal fixation. Polyether ether ketone (PEEK) has been widely used in spinal fusion and cranioplasty given its excellent biomechanical properties, biocompatibility, and stability.

View Article and Find Full Text PDF

Objective: To evaluate the feasibility and safety of three-dimensional (3D) printed drill guide template-assisted percutaneous pedicle screw fixation for multiple-level thoracolumbar fractures.

Methods: Clinical data of 19 patients with multilevel thoracolumbar fracture without nerve injury who underwent surgical treatment between May 2017 and January 2019 were retrospectively analyzed. There were 9 males and 10 females and their age ranged from 22 to 63 years, with an average age of 43.

View Article and Find Full Text PDF