Publications by authors named "Babak Mahmoudian"

Background: Unilateral chronic thromboembolism pulmonary disease (CTEPD) is very rare. There is limited information on the safety and efficacy of pulmonary endarterectomy (PEA) in this population. This study investigated the effectiveness of PEA in this unique disease.

View Article and Find Full Text PDF

Propose: This study aimed to compare the diagnostic accuracy of MR dacryocystography (MRD) and dacryoscintigraphy (DSG) in the diagnosis of acquired epiphora related to NLDO. A total of 15 patients with acquired epiphora and suspected NLDO were included in this study.

Methods: All patients underwent MRD and DSG examinations.

View Article and Find Full Text PDF

 Collimators have a significant role in image quality and detectability in single-photon emission computed tomography (SPECT) imaging. Using an appropriate alloy that effectively absorbs scattered photons, without induced secondary x-rays, and with proper rigidity and weight may provide an effective approach to the image improvement that conventionally collimators made of lead (Pb).  A Siemens E.

View Article and Find Full Text PDF
Article Synopsis
  • Pulmonary endarterectomy (PEA) is a key treatment for chronic thromboembolic pulmonary hypertension (CTEPH), and this study assessed its effectiveness in Tabriz, Iran, over four years.
  • The analysis included 42 patients who experienced significant improvements in heart function, pulmonary pressure, and overall endurance, with some complications observed post-surgery.
  • The findings suggest that PEA is a safe procedure with low mortality rates and emphasize the need for increased awareness and access to qualified treatment centers for CTEPH patients.
View Article and Find Full Text PDF

Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is a serious condition that results from incomplete resolution of thromboemboli in pulmonary arteries. Symptomatic patients with chronic thromboembolic disease may have normal hemodynamic at rest. The aim of this study is to evaluate the outcome of pulmonary endarterectomy (PEA) in symptomatic patients with chronic thromboembolic pulmonary disease (CTEPD) in the absence of pulmonary hypertension as currently defined (mean pulmonary artery pressure [mPAP] < 20 mm Hg).

View Article and Find Full Text PDF

Abomasal hypomotility is one of the important causes of neonatal mortality in small ruminants. Various pharmaceutical agents have been studied to address this problem in large ruminants. The aim of this study was to determine the effect of parenteral administration of tylosin and ivermectin on abomasal emptying rate in neonatal suckling lambs.

View Article and Find Full Text PDF

Evaluation of atypical presentation of angina chest pain in emergency department is difficult. Hospitalization of this patient may impose additional costs and waste the time, early discharge may lead to miss the patients. The aim of this study was to determine volubility of Single Photon Emission Computed Tomography (SPECT) in management of patients admitted to emergency department with atypical manifestations of angina pain, un-diagnostic Electrocardiogram (ECG) and negative enzyme.

View Article and Find Full Text PDF

Collimator geometry has an important contribution on the image quality in SPECT imaging. The purpose of this study was to investigate the effect of parallel hole collimator hole-size on the functional parameters (including the spatial resolution and sensitivity) and the image quality of a HiReSPECT imaging system using SIMIND Monte Carlo program. To find a proper trade-off between the sensitivity and spatial resolution, the collimator with hole diameter ranges of 0.

View Article and Find Full Text PDF

Background: Mesoporous nanoparticles have a great potential in targeted therapy approaches due to their ideal properties for encapsulation of various drugs, proteins and also biologically active molecules.

Material And Methods: We used mesoporous hydroxyapatite (HA) nanoparticles as a drug carrier and developed radiolabeled mesoporous HA containing of 2-deoxy-D-glucose (2DG) and Doxorubicin (DOX) with technetium-99m (99mTc) for imaging in in vitro and in vivo studies.

Results: 2DG and DOX in presence of mesoporous HA nanoparticles more reduced the fraction of viable cells in the MDA-MB-231, MCF-7 human and MC4-L2 Balb/c mice breast cancer cells.

View Article and Find Full Text PDF

The detector in single-photon emission computed tomography has played a key role in the quality of the images. Over the past few decades, developments in semiconductor detector technology provided an appropriate substitution for scintillation detectors in terms of high sensitivity, better energy resolution, and also high spatial resolution. One of the considered detectors is cadmium telluride (CdTe).

View Article and Find Full Text PDF

Background: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector is a critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affected by the attenuation, scattering, and response of the detector.

View Article and Find Full Text PDF

The detector is a critical component of the single photon emission computed tomography (SPECT) imaging system for giving accurate information from the exact pattern of radionuclide distribution in the target organ. The SIMIND Monte Carlo program was utilized for the simulation of a Siemen's dual head variable angle SPECT imaging system with a low energy high resolution (LEHR) collimator. The Planar and SPECT scans for a (99m)Tc point source and a Jaszczak Phantom with the both experiment and simulated systems were prepared and after verification and validation of the simulated system, the similar scans of the phantoms were compared (from the point of view of the images' quality), namely, the simulated system with the detectors including bismuth germanate (BGO), yttrium aluminum garnet (YAG:Ce), Cerium-doped yttrium aluminum garnet (YAG:Ce), yttrium aluminum perovslite (YAP:Ce), lutetium aluminum garnet (LuAG:Ce), cerium activated lanthanum bromide (LaBr3), cadmium zinc telluride (CZT), and sodium iodide activated with thallium [NaI(Tl)].

View Article and Find Full Text PDF

Treatment efficacy of radioembolization using Yttrium-90 ((90)Y) microspheres is assessed by the (90)Y bremsstrahlung single photon emission computed tomography (SPECT) imaging following radioembolization. The radioisotopic image has the potential of providing reliable activity map of (90)Y microspheres distribution. One of the main reasons of the poor image quality in (90)Y bremsstrahlung SPECT imaging is the continuous and broad energy spectrum of the related bremsstrahlung photons.

View Article and Find Full Text PDF

The collimator in single-photon emission computed tomography (SPECT) is a critical component of the imaging system and plays an impressive role in the imaging quality. In this study, the effect of the collimator material on the radioisotopic image and its functional parameters was studied. The simulating medical imaging nuclear detectors (SIMIND) Monte Carlo program was used to simulate a Siemens E.

View Article and Find Full Text PDF

High-quality image is necessary for accurate diagnosis in nuclear medicine. There are many factors in creating a good image and detector is the most important one. In recent years, several detectors are studied to get a better picture.

View Article and Find Full Text PDF

Radioembolization (RE) with Yttrium-90 ((90)Y) microspheres is an effective treatment for unresectable liver tumors. The activity of the microspheres to be administered should be calculated based on the type of microspheres. Technetium-99m macroaggregated albumin ((99m)Tc-MAA) single photon emission computed tomography/computed tomography (SPECT/CT) is a reliable assessment before RE to ensure the safe delivery of microspheres into the target.

View Article and Find Full Text PDF

The collimator in single photon emission computed tomography (SPECT), is an important part of the imaging chain. One of the most important collimators that used in research, preclinical study, small animal, and organ imaging is the pinhole collimator. Pinhole collimator can improve the tradeoff between sensitivity and resolution in comparison with conventional parallel-hole collimator and facilities diagnosis.

View Article and Find Full Text PDF

Scanning using a somatostatin receptor analog such as Tc-EDDA/HYNIC-TOC has sensitivity and specificity similar to those of FDG-PET, which has high accuracy in the characterization of a solitary pulmonary nodule (SPN). We describe a 63-year-old man with well-defined SPN in the left lung on chest x-ray and CT scan. Whole-body scanning and chest SPECT were performed with Tc-EDDA/HYNIC-TOC for the characterization of SPN.

View Article and Find Full Text PDF

Background: The ability of low dose dobutamine (LDD) has been established in exploiting the reserved contractility of ischemic myocardium. This study was designed to assess the value of a new protocol, with an additional stress imaging during LDD infusion instead of the rest images, for evaluation of coronary artery disease (CAD) and perfusion reversibility.

Methods: A total of 51 patients (42 men, 9 women; 57.

View Article and Find Full Text PDF

Bronchial carcinoma is the leading cause of death from cancer in most countries. The aim of this prospective study was to assess the ability of 99mTechnetium Sestamibi (99mTc-MIBI) SPECT in differentiating benign from malignant pulmonary masses. 30 patients with lung mass, radiologically suspicious for malignancy were included.

View Article and Find Full Text PDF

Background: Although coronary artery disease is a major cause of mortality and morbidity in patients undergoing hemodialysis, there is no accurate diagnostic strategy for these patients.

Aim: To assess the value of 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) gated single-photon emission computed tomography for the detection of silent myocardial ischemia in patients undergoing hemodialysis and to evaluate the clinical variables associated with abnormal test results.

Methods: Thirty-one asymptomatic patients undergoing hemodialysis (20 men, 11 women), with a mean age of 45 years (range, 25-75 years), were included in the study.

View Article and Find Full Text PDF