Background: Model-based dose calculation algorithms (MBDCA), such as the Advanced Collapsed cone Engine (ACE) in Oncentra Brachy® can be used to overcome the limitations of the TG-43 formalism. ACE is a point kernel superposition algorithm that calculates the total dose separated into primary, first-scatter, and multiple-scatter dose. Albeit ACE yields accurate results under most circumstances, several studies have reported underestimations of the dose to cortical bone.

View Article and Find Full Text PDF

Purpose: The direction modulated brachytherapy (DMBT) magnetic resonance-compatible tandem applicator, made from a tungsten alloy rod, has six symmetric peripheral grooves, designed specifically to enhance intensity modulation capacity through achieving directional radiation dose profiles. In this work, the directional dose distributions of the DMBT tandem were modeled and calculated with the Oncentra Brachy advanced collapsed cone engine (ACE), which was validated against Monte Carlo (MC) calculations.

Methods And Material: The prototype 3D tandem applicator model was created for use in the Oncentra Brachy treatment planning system.

View Article and Find Full Text PDF

Purpose: To investigate the dose calculation accuracy of the Advanced Collapsed cone Engine (ACE) algorithm for ocular brachytherapy using a COMS plaque loaded with I-125 seeds for two heterogeneous patient tissue scenarios.

Methods: The Oncura model 6711 I-125 seed and 16 mm COMS plaque were added to a research version (v4.6) of the Oncentra Brachy (OcB) treatment planning system (TPS) for dose calculations using ACE.

View Article and Find Full Text PDF

As a prerequisite for clinical treatments it was necessary to characterize the Elekta 1.5 T MRI-linac 7 MV FFF radiation beam. Following acceptance testing, beam characterization data were acquired with Semiflex 3D (PTW 31021), microDiamond (PTW 60019), and Farmer-type (PTW 30013 and IBA FC65-G) detectors in an Elekta 3D scanning water phantom and a PTW 1D water phantom.

View Article and Find Full Text PDF

Purpose: To investigate the dose calculation accuracy in water medium of the Advanced Collapsed cone Engine (ACE) for three sizes of COMS eye plaques loaded with low-energy I-125 seeds.

Methods: A model of the Oncura 6711 I-125 seed was created for use with ACE in Oncentra Brachy (OcB) using primary-scatter separated (PSS) point dose kernel and Task Group (TG) 43 datasets. COMS eye plaque models of diameters 12, 16, and 20 mm were introduced into the OcB applicator library based on 3D CAD drawings of the plaques and Silastic inserts.

View Article and Find Full Text PDF