Publications by authors named "B Willemart"

Objectives: This study aimed to introduce an improved deconvolution technique for Tc-99m-mercaptoacetyltriglycine renograms based on the combination of a sparse Legendre polynomial representation and the Moore-Penrose inversion matrix (LG). This method reduces the effect of noise on the measurement of renal retention function transit time (TT).

Methods: The stability and accuracy of the proposed method were tested using a renal database containing Monte Carlo-simulated studies and real adult patient data.

View Article and Find Full Text PDF

Unlabelled: Scintimammography (SM) can be used as a complementary test to mammography in patients with suspected breast cancers. This study was undertaken to evaluate the impact of SM on the management of patients with a doubtful or discordant triple diagnosis-that is, mammography, ultrasound, and fine-needle aspiration cytology. The clinical question was variable: initial diagnosis of cancer, suspicion of recurrence, doubtful tumor extension, or search for a primary tumor.

View Article and Find Full Text PDF

Objectives: This study was conducted to examine the efficacy of dobutamine stress two-dimensional echocardiography and perfusion scintigraphy for the detection of coronary artery disease in routine practice, to establish the causes of erroneous results and to derive appropriate criteria for the selection of either or both tests.

Background: Dobutamine stress combined with echocardiography or perfusion scintigraphy may be used to detect coronary artery disease. Although both imaging approaches have demonstrated similar levels of accuracy, it is not known whether there may be particular indications for the use of one or the other technique or a rationale for their combination.

View Article and Find Full Text PDF

Background: The mechanisms of action of exercise-simulating and vasodilator stressors support their combination with imaging techniques that evaluate left ventricular function and perfusion, respectively. However, reported accuracies of either pharmacological stress together with two-dimensional echocardiography (2DE) or single photon emission computed tomography (SPECT) of myocardial perfusion are similar. The purpose of this study was to establish the optimal stress for each imaging technique by comparing the results of digitized 2DE and 99mTc-methoxyisobutyl isonitrile (MIBI) SPECT using both dobutamine and adenosine stresses in the same patients and conditions.

View Article and Find Full Text PDF