Publications by authors named "B Vikhoff"

The difference between the experimental and theoretical spatial response function (SRF) of a narrow tube with water is used for a localization test for magnetic resonance spectroscopic imaging (MRSI). From this difference a quantitative performance parameter is derived for the relative amount of signal within a limited region in the field of view. The total signal loss by the MRSI experiment and eddy currents is described by a parameter SL derived from the signal intensities of two echoes.

View Article and Find Full Text PDF

A two-compartment gel phantom for VOI profile measurements in volume-selective 31P spectroscopy in small-bore units is presented. The phantom is cylindrical with two compartments divided by a very thin (30 microm) polyethene film. This thin film permits measurements with a minimum of susceptibility influences from the partition wall.

View Article and Find Full Text PDF

Purpose: To compare the contrast effects of gadodiamide injection at 0.3 and at 1.5 T, at different concentrations in phantoms, and to correlate the results to clinical doses used for examining brain lesions.

View Article and Find Full Text PDF

An investigation regarding possible artefacts from dental filling materials in MR imaging is presented including 9 types of such materials from various manufacturers. Freshly extracted teeth were prepared and the filling materials were handled according to manufacturers' instructions. The teeth were encapsulated into a gel phantom based on de-ionized water, Ni (NO3)2 and polysaccharide agarose powder.

View Article and Find Full Text PDF

This paper reports the results of multicentre studies aimed at designing, constructing, and evaluating prototype test objects for performance assessment in small-bore MRS systems, by utilizing the test protocols already proposed by the EEC COMAC-BME Concerted Action for clinical MRS equipment. Three classes of test objects were considered: (1) a multicompartment test object for 31P MRS measurements performed with slice-selective sequences; (2) a two-compartment test object for volume-selection 1H MRS; and (3) two-compartment test objects for assessing the performance of experimental systems using ISIS as volume localization sequence in 31P MRS. The results suggested the interest of adopting some of these prototypes for improving the comparison of spectroscopy data obtained from different sites, for providing useful means of quality assurance in experimental MRS, and facilitating the validation of new localization sequences.