Publications by authors named "B Trenary"

Many modern tower silos used in the agricultural industry for hay and grain storage are oxygen-limiting by design. Forced-air ventilation using a forage blower is a method commonly used to decrease concentrations of toxic and asphyxiant gases and to increase the O2 content within a silo headspace prior to worker entry. This article describes the methods used to measure gas concentrations and the results obtained from a pilot study by the Washington Fatality Assessment and Control Evaluation (FACE) program of two oxygen-limiting forage tower silos in eastern Washington State.

View Article and Find Full Text PDF