Publications by authors named "B Nutter"

The I21 beamline at Diamond Light Source is dedicated to advanced resonant inelastic X-ray scattering (RIXS) for probing charge, orbital, spin and lattice excitations in materials across condensed matter physics, applied sciences and chemistry. Both the beamline and the RIXS spectrometer employ divergent variable-line-spacing gratings covering a broad energy range of 280-3000 eV. A combined energy resolution of ∼35 meV (16 meV) is readily achieved at 930 eV (530 eV) owing to the optimized optics and the mechanics.

View Article and Find Full Text PDF

Currently, functional magnetic resonance imaging (fMRI) is the most commonly used technique for obtaining dynamic information about the brain. However, because of the complexity of the data, it is often difficult to directly visualize the temporal aspect of the fMRI data. We outline a -distributed stochastic neighbor embedding (t-SNE)-based postprocessing technique that can be used for visualization of temporal information from a 4D fMRI data.

View Article and Find Full Text PDF

Through the last three decades, functional magnetic resonance imaging (fMRI) has provided immense quantities of information about the dynamics of the brain, functional brain mapping, and resting-state brain networks. Despite providing such rich functional information, fMRI is still not a commonly used clinical technique due to inaccuracy involved in analysis of extremely noisy data. However, ongoing developments in deep learning techniques suggest potential improvements and better performance in many different domains.

View Article and Find Full Text PDF
Article Synopsis
  • The text describes a newly commissioned four-bounce crystal monochromator for the XAS beamline at Diamond Light Source, featuring a unique design with two independent rotary axes.
  • The device maintains flux throughput without external feedback from 4 to 20 keV and is currently equipped with cryogenically cooled Si(111) crystals.
  • Preliminary designs allow for the potential installation of an additional Si(311) crystal-set to increase the energy range to 34 keV, with experimental data supporting its mechanical stability and repeatability.
View Article and Find Full Text PDF

Background: Comparative efficacy of same-day bowel preparations for colonoscopy remains unclear.

Aims: A meta-analysis of randomized controlled trials comparing the efficacy of same-day versus split dose bowel preparations for colonoscopy.

Methods: A systematic search was conducted in MEDLINE, clinicaltrials.

View Article and Find Full Text PDF