Stable and uniform beams with low divergence are required in particle accelerators; therefore, beyond the accelerated current, measuring the beam current spatial uniformity and stability over time is necessary to assess the beam performance, since these parameters affect the perveance and thus the beam optics. For high-power beams operating with long pulses, it is convenient to directly measure these current parameters with a non-intercepting system due to the heat management requirement. Such a system needs to be capable of operating in a vacuum in the presence of strong electromagnetic fields and overvoltages, due to electrical breakdowns in the accelerator.
View Article and Find Full Text PDFThe full-size ITER ion source prototype SPIDER (Source for the Production of Ions of Deuterium Extracted from a Radio frequency plasma) has recently started beam operation, whose objective is to produce 100 keV, 60 A hydrogen negative ions for 1 h. The source is presently operated in the volume regime, and the beam power is consequently limited. In such a configuration, the high resolution calorimeter STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment), even though uncooled, may be used instead of the SPIDER beam dump without limiting the beam-on time.
View Article and Find Full Text PDFThe NIO1 (Negative Ion Optimization phase 1) source can provide continuous beam operation, which is convenient for systematic parameter and equipment studies. Even in the pure volume production regime, the source yield was found to depend on conditioning procedures. Magnetic configuration tests continued adding magnets to the existing setup; the filter field component B has been progressively extended to span the -12 to 5 mT range, and as a trend, source performances improved with |B|.
View Article and Find Full Text PDFNeutral Beam Injectors (NBIs), which need to be strongly optimized in the perspective of DEMO reactor, request a thorough understanding of the negative ion source used and of the multi-beamlet optics. A relatively compact radio frequency (rf) ion source, named NIO1 (Negative Ion Optimization 1), with 9 beam apertures for a total H(-) current of 130 mA, 60 kV acceleration voltage, was installed at Consorzio RFX, including a high voltage deck and an X-ray shield, to provide a test bench for source optimizations for activities in support to the ITER NBI test facility. NIO1 status and plasma experiments both with air and with hydrogen as filling gas are described.
View Article and Find Full Text PDF