We report the fabrication of a 3D micropatterned agarose substrate that enables the culture of single or multiple cells. Patterning was performed on dried agarose using deep UV irradiation leading to 6-microm-deep micropatterns of 25-70 microm in diameter. Cell adhesion was facilitated by the specific grafting of ECM (extra cellular matrix) proteins such as fibronectin into the micropatterns.
View Article and Find Full Text PDFTo analyze the phenotypic consequences of perturbing mammalian cells with drugs, there is an increasing need for systematic cell-based assays in an HTS format. Cell microarrays provide an attractive solution as they offer more than a simple miniaturization and mechanization of conventional microtiter plates. While standard monolayer two-dimensional culture conditions are poor mimics of the cellular environment in situ, microfabricated systems enable three-dimensional organotypic cell cultures and have the potential to provide biological insight not achievable before.
View Article and Find Full Text PDFBiosens Bioelectron
April 2007
Today, microarray fluorescence detection is still limited because a great proportion of hybrids remain undetectable. In this paper we describe sol-gel optical multilayers (stacks of low- and high-index layers) deposited on glass slides which increase the fluorescence of DNA microarrays and favour the detection of fluorescent targets. An alternative to the expensive and time-consuming physical vapour deposition technology is proposed.
View Article and Find Full Text PDFA simple way for photochemical patterning of biological molecules onto the inner wall of fused-silica capillary is described. The method is based on a modification of the inner capillary surface with photoactive benzophenone (BP) derivative. The UV irradiation at 365 nm of the capillary filled with a sample solution results in cross-linking of the solutes to the BP moiety via a stable covalent bond.
View Article and Find Full Text PDFIn microarrays experiments, a serious limitation is the unreliability of low signal intensities data and the lack of reproducibility for the resulting ratios between samples and controls. Most of the light emitted by a fluorophore at the air/glass interface of a glass slide is absorbed by the glass so just a part of the emitted fluorescence is detected. To improve the sensitivity of the fluorescence detection of both common fluorophores Cy3 and Cy5 in DNA microarrays and fluorescent cell analyses, we have designed a multi layer mirror with alternative thin layers of SiO2 and HfO2.
View Article and Find Full Text PDF