Background: As volatile anaesthetic gases contribute to global warming, improving the efficiency of their delivery can reduce their environmental impact. This can be achieved by rebreathing from a circle system, but also by anaesthetic reflection with an open intensive care ventilator. We investigated whether the efficiency of such a reflection system could be increased by warming the reflector during inspiration and cooling it during expiration (thermocycling).
View Article and Find Full Text PDFPurpose: The aim of our prospective, randomized, double-blind, placebo-controlled study was to investigate the effect of laser acupuncture on postoperative pain in women undergoing cesarean section.
Methods: 99 women (mean age 32 ± 5 years) scheduled for cesarean section under spinal anesthesia at Saarland University Hospital Medical Center, Homburg (Germany) were enrolled in this trial after giving written consent. Patients were randomized in two groups receiving a course of 3 treatments over 3 days with either active or placebo laser.
Background: Spontaneous breathing is desirable in most ventilated patients. We therefore studied the influence of isoflurane versus propofol sedation on early spontaneous breathing in ventilated surgical intensive care patients and evaluated potential mediation by opioids and arterial carbon dioxide during the first 20 h of study sedation.
Methods: We included a single-center subgroup of 66 patients, who participated in a large multi-center trial assessing efficacy and safety of isoflurane sedation, with 33 patients each randomized to isoflurane or propofol sedation.
Purpose: In this retrospective study, we compared inhaled sedation with isoflurane to intravenous propofol in invasively ventilated COVID-19 patients with ARDS (Acute Respiratory Distress Syndrome).
Methods: Charts of all 20 patients with COVID-19 ARDS admitted to the ICU of a German University Hospital during the first wave of the pandemic between 22/03/2020 and 21/04/2020 were reviewed. Among screened 333 days, isoflurane was used in 97 days, while in 187 days, propofol was used for 12 h or more.
: Adequate sedation is important for the treatment of ICU patients. AnaConDa (Anesthetic-Conserving-Device; ACD; Sedana Medical, Sweden), connected between ventilator and the patient, retains isoflurane during expiration, and releases it back during inspiration. The reflection efficiency (Ref) corresponds to the percentage of expired anesthetic molecules that are re-inspired.
View Article and Find Full Text PDFBackground: Contemporary anesthetic circle systems, when used at low fresh gas flows (FGF) to allow rebreathing of anesthetic, lack the ability for rapid dose titration. The small-scale anesthetic reflection device Anaesthetic Conserving Device (50mL Version; AnaConDa-S) permits administration of volatile anesthetics with high-flow ventilators. We compared washin, washout, and sevoflurane consumption using AnaConDa-S versus a circle system with low and minimal FGF.
View Article and Find Full Text PDF