The Go-BACK catheter is a novel device designed to be used for both intraluminal crossing or re-entry, into a vessel lumen from the subintimal space during subintimal angioplasty. It is reserved for cases where reentry has not been possible using conventional wire and catheter techniques. We report our experience in recanalization of the chronic total occlusions of the common iliac artery (CIA) using the Go-BACK catheter, in cases where other techniques were unsuccessful.
View Article and Find Full Text PDFBackground: Recanalization of graft limb occlusion can prove challenging and the use of the GoBack crossing and reentry device may be a suitable option, especially when there is no other way to restore flow with an usual endovascular approach. The GoBack catheter is a novel device designed to enhance pushability, and to enable direction-change inside hard plaques and crossing of tough lesions, even when they involve graft fabric.
Case Presentation: It's reported a case of a 76-year-old male who presented with claudication, previous placement of an aorto-bi iliac graft by open surgery for a ruptured abdominal aneurysm 10 years ago that, over time, developed severe kinking on the left limb and a fabric occlusion on the right limb.
Purpose: To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity.
Materials And Methods: MESD were evaluated with radiochromic films in 31 patients (mean age 72 ± 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD.
Study Design: We studied the radiation doses to which patients were exposed during 17 vertebroplasty operations.
Objective: The radiation doses during vertebroplasty were measured to determine maximum skin dose (MSD), a measure of the likelihood of radiation-induced skin effects.
Summary Of Background Data: Vertebroplasty is performed with use of fluoroscopic guidance for needle placement and to monitor bone cement injection.
Background: The aim of the present study was to evaluate the survival, efficacy and safety of a modified RADPLAT-like protocol using carboplatin instead of cisplatin.
Methods: Fifty-six patients with primary head and neck squamous cell carcinoma received 4 cycles of intra-arterial carboplatin (350 mg/m2 per cycle every 2 weeks), with concurrent three-dimensional conformal radiation therapy.
Results: Two major and 4 minor complications were observed.
Background: While conventional transhepatic arterial chemoembolization (TACE) is accepted worldwide as an effective treatment for patients with unresectable hepatocellular carcinoma (HCC), its use in other hepatic tumors is not supported by randomized studies. Preliminary results have shown that new drug-eluting microspheres (DEM) seem to optimize TACE procedures. The aim of this study was to evaluate the capability of HepaSphere to load oxaliplatin and their pharmacokinetic outcome.
View Article and Find Full Text PDFWe describe a case of incidental detection of an intracranial left ICA wide-necked aneurysm during digital subtraction angiography performed to assess a sub-occlusive and calcified stenosis in the extracranial portion of the same artery. Angioplasty and stenting of ICA stenosis, plus intracranial stent deployment across the aneurysm neck was performed during the same procedure. Aneurysm coil embolization was postponed to a further session one month later.
View Article and Find Full Text PDFBackground And Purpose: It is essential to measure the skin dose of radiation received by patients during interventional neuroradiologic procedures performed under fluoroscopic guidance, such as embolization of cerebral aneurysms, which is regarded as a high-dose interventional radiology procedure. In this study, we report a method for evaluating maximum skin dose (MSD), an ideal marker of radiation-induced effects, based on an innovative use of radiochromic films.
Materials And Methods: Forty-eight procedures were studied in 42 patients undergoing embolization of cerebral aneurysms.
Purpose: To investigate a method for evaluation of the maximum skin dose (MSD) of radiation in patients undergoing interventional radiology procedures in the liver.
Materials And Methods: Transarterial chemoembolization, transarterial embolization, portal vein embolization, and biliary interventions were the procedures considered in this study. Ninety procedures in 70 patients were studied.
The aim of the current study was to evaluate the safety and the efficacy of radiofrequency thermal ablation (RFTA) for the treatment of nonsmall cell lung cancer (NSCLC) and isolated pulmonary metastases (METs) from colorectal cancer (CRC). A total of 31 patients (15 with NSCLCs and 16 with CRC lung METs), with 36 lung tumour nodules (mean+/-sd diameter: 22+/-8 mm, range: 10-35 mm) underwent computed tomography (CT)-guided RFTA using expandable electrodes. Contrast-enhanced CT was performed before and after (immediately and 30+/-5 days) each RFTA session to assess immediate results and complications and repeated 3 and 6 months post-RFTA, as well as every 6 months thereafter, to evaluate long-term results.
View Article and Find Full Text PDFObjective: We conducted a prospective study to compare sonography, color Doppler sonography, and contrast-enhanced sonography for the detection and characterization of portal and hepatic vein thrombosis complicating hepatic malignancies.
Subjects And Methods: Three hundred sixteen patients with biopsy-proved hepatic tumors were studied at baseline and 3 months later with sonography, color Doppler sonography, and contrast-enhanced sonography. Thrombosis was defined as the presence of intraluminal echogenic material at sonography, absence of intraluminal color signals at color Doppler sonography, and presence of nonenhancing intraluminal area at contrast-enhanced sonography.
Purpose: To evaluate the concordance of the enhancement patterns of a new ultrasound contrast agent (SonoVue) with those obtained with dual-phase contrast-enhanced spiral CT (CE-CT) in the characterization of focal liver lesions (FLLs).
Materials And Methods: Sixty-two patients with focal liver lesions discovered at ultrasound and also studied with CECT underwent contrast-enhanced ultrasound using continuous low acoustic power imaging after receiving a 2.4 ml bolus of the new US contrast agent SonoVue, consisting of a dispersion of sulphur hexafluoride microbubbles.
Gray scale sonography and US-guided biopsy are cost-effective and reliable procedures in the differential diagnosis of focal thyroid lesions. The frequent presence of multiple foci can make multiple biopsies intolerable to the patient. The use of a sonographic contrast agent (Levovist) composed of microbubbles was evaluated in the differential diagnosis of focal solid lesions of the thyroid.
View Article and Find Full Text PDF