Plane wave imaging persists as a focal point of research due to its high frame rate and low complexity. However, in spite of these advantages, its performance can be compromised by several factors such as noise, speckle, and artifacts that affect the image quality and resolution. In this paper, we propose an attention-based complex convolutional residual U-Net to reconstruct improved in-phase/quadrature complex data from a single insonification acquisition that matches diverging wave imaging.
View Article and Find Full Text PDFBackground: Over the past decades, total shoulder arthroplasty (TSA) procedures have steadily increased in the United States and Europe. In France, the number of shoulder surgeries rose by 24.5% between 2012 and 2018, but no study has yet analyzed TSA trends based on patient characteristics.
View Article and Find Full Text PDFThe usual Lewinnek orientation for cup positioning in total hip arthroplasty is not suitable for all patients as it does not consider the patient mobility. We propose an ultrasound-based approach to compute a Functional Safe Zone (FSZ) considering daily positions. Our goal was to validate it, and to evaluate how the input parameters impact the FSZ size and barycentre.
View Article and Find Full Text PDFOrienting properly the prosthetic cup in total hip arthroplasty is key to ensure the postoperative stability. Several navigation solutions have been developed to assist surgeons in orienting the cup regarding the anterior pelvic plane (APP), defined by both anterior superior iliac spines (ASIS) and the pubic symphysis. However acquiring the APP when the patient is ready for surgery, i.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2020
The anterior pelvic plane (APP) defined by both iliac spines and the pubic symphysis, is essential in total hip arthroplasty (THA) for the orientation of the prosthetic cup. However, the APP is nowadays still difficult to determine in computer assisted orthopedic surgery (CAOS). We propose to use a statistical shape model (SSM) of the pelvis to estimate the APP from ipsilateral anatomical landmarks, more easily accessible during surgery in computer assisted THA with the patient in lateral decubitus position.
View Article and Find Full Text PDFObjectives: A new ultrasound-based device is proposed to measure the patient-specific pelvic tilt in different daily positions. The aim of this study was to assess the accuracy of this device as well as the intraobserver and interobserver precisions.
Methods: The accuracy was assessed by performing several tilt measurements with the device on a testing mechanical bench.