This paper presents an evaluation of hexabromocyclododecane (HBCD), polybrominated dibenzo-p-dioxins/furans (PBDD/Fs) and polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs) outflows during the destruction of HBCD waste stockpiles in IZAYDAS Hazardous Waste Incinerator (HWI) in Kocaeli, Türkiye. HBCD wastes containing 100 % pure HBCD were in 25 kg packages with 63 % Br content were co-incinerated in a 3-day test burn with average feed rate of 26 kg/h. HBCD, PBDD/Fs and PCDD/Fs were measured in the outlet streams to quantify the amount of unintended POPs releases associated with the processing of HBCD waste and to observe the POP removal performance of air pollution control equipment (APCE) of the incinerator.
View Article and Find Full Text PDFThe current situation of the water resources of Istanbul, which is one of the important metropolises of Europe, should be known and constantly monitored by the reasons of the rapid increase in the city population, the acceleration of production-related industrial activities, the expansion of the city with construction activities, and the decrease in precipitation. The purpose of this study was to reveal the situations of surface sediments collected from Istanbul water reservoirs in terms of PCDD/Fs and DL-PCBs, to identify possible sources, and to conduct their ecological risk assessment. Total PCDD/Fs and DL-PCBs concentrations varied between 28.
View Article and Find Full Text PDFThe study includes the determination of the general background PCDD/F and dl-PCB levels in environmental (ambient air and soil) and food (meat, milk, egg, leafy vegetable, root vegetable and fruit samples) samples collected in four sampling sites in the vicinity of IZAYDAS WIP and its possible health risks. The local and meteorological conditions (prevailing wind direction, season, raining, and soil structure) were taken into account in the selection of sampling sites. The concentrations of PCDD/F and dl-PCB in ambient air ranged from 0.
View Article and Find Full Text PDFEcological problems arising after the construction and operation of a waste incineration plant generally originate from incorrect decisions made during the selection of the location of the plant. The main objective of this study is to investigate how the selection method for the location of a new municipal waste incineration plant can be improved by using a dispersion modelling approach supported by geographical information systems and multi-criteria decision analysis. Considering this aim, the appropriateness of the current location of an existent plant was assessed by applying a pollution dispersion model.
View Article and Find Full Text PDFPerfluorooctane sulfonic acid (PFOS) and related substances have been listed as persistent organic pollutants (POPs) in the Stockholm Convention. Countries which have ratified the Convention need to take appropriate actions to control PFOS use and release. This study compiles and enhances the findings of the first inventory of PFOS and related substances use in Turkey conducted within the frame of the Stockholm Convention National Implementation Plan (NIP) update.
View Article and Find Full Text PDFAs studies on municipal solid waste management increased in recent years, many new mathematical models and approaches with a focus on determining the best treatment and disposal scenario were developed and applied. In this study, a mixed integer linear programming model was developed to be used as a facilitative tool for the cost minimisation of municipal solid waste management practices. Since municipal solid waste mass is a mixed composition of various types of waste components with different physical and chemical properties, the model was designed to include all the suitable treatment and disposal methods for these different waste components.
View Article and Find Full Text PDFJ Air Waste Manag Assoc
February 2014
The procedure of a multi-criteria decision analysis supported by the geographic information systems was applied to the site selection process of a planning municipal solid waste management practice based on twelve different scenarios. The scenarios included two different decision tree modes and two different weighting models for three different area requirements. The suitability rankings of the suitable sites obtained from the application of the decision procedure for the scenarios were assessed by a factorial experimental design concerning the effect of some external criteria on the final decision of the site selection process.
View Article and Find Full Text PDFUnlabelled: This study includes an application of the first two phases of a new three-phased decision-making structure that was developed to overcome the problems related to ecological safety and social justice in site selection applications. It was conducted on a current site selection problem related to the municipal solid waste disposal facilities in Kocaeli, the most industrialized region of Turkey. In order to assess the deficiencies of the legal site selection procedures related to ecological safety, two different decision tree modes were applied separately.
View Article and Find Full Text PDFUnlabelled: A study was conducted to observe the changes in polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) levels and congener profiles in the flue gas of a hazardous waste incinerator during two start-up periods. Flue gas samplings were performed simultaneously through Air Pollution Control Devices (APCDs) (including boiler outlet, electrostatic precipitator (ESP) outlet, wet scrubbers (WS) outlet, and activated carbon (AC) filter outlet) in different combustion temperatures during a planned cold (long) start-up and an unplanned warm (short) start-up. The results showed that PCDD/F concentrations could be elevated during the start-up periods up to levels 3-4 times higher than those observed in the normal operation.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
September 2013
This study evaluates PCDD/F pollution in the surface sediments of Izmit Bay (Turkey) and assesses the possible sources of PCDD/F inputs to the bay. The results showed that concentrations of toxic PCDD/F congeners in the sediments varied between 0.45 and 255 ng WHO2005-TEQ/kg dry weight.
View Article and Find Full Text PDFA sampling and analysis program were conducted to determine the PCDD/F levels in various food samples collected in Kocaeli, one of the highly polluted areas in Turkey. Several food samples including animal (egg, chicken, meat and cow's milk) and plant (fruits, leafy vegetables, fruiting vegetables, rooty vegetables and flour) products were collected from both local and non-local (commercial) sources. The local food samples were taken from 20 sampling points selected by taking into account the location of the possible PCDD/F sources, dominant wind directions and representing the major part of the Turkish daily diet The PCDD/F concentrations in local eggs and milk samples were ranged from <1.
View Article and Find Full Text PDFThis study focuses on a health risk assessment related to benzene, toluene, ethylbenzene, and m,p,o-xylene (xylenes) (BTEX) exposure via inhalation for workers at a landfill (LF) site. First, the landfill gas (LFG) samples were collected and analyzed accordance with US EPA method TO-17. The mean concentrations of benzene, toluene, ethylbenzene, and xylenes were determined as 140.
View Article and Find Full Text PDFBackground: Children's developing teeth may be sensitive to environmental pollutants such as polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans. The term molar incisor hypomineralization (MIH) was introduced to describe the clinical appearance of enamel hypomineralization of systemic origin affecting one or more permanent first molars (PFMs) that are associated frequently with affected incisors.
Aim: The aim of this study was to determine the prevalance of MIH in children from the most industrialized and polluted region and the most green-energy island of Turkey.
J Environ Sci Health A Tox Hazard Subst Environ Eng
May 2007
An estimation and assessment of the polychlorinated dibenzo-p-dioxins and polychlorinated dibenzo furans (PCDD/Fs) exposure levels for the people living in Kocaeli, the most industrialized area of Turkey, are presented. The information is based on the results of PCDD/F analyses in the samples collected from various environmental media and the multimedia exposure assessment methodology. Exposure scenarios were constructed on a site-specific basis by combining the exposure pathways appropriate to the area, and the activity patterns of the people living in Kocaeli.
View Article and Find Full Text PDFEnviron Monit Assess
May 2007
This study aims to obtain a reliable inventory of the emission rates of the principal air pollutants including PM, SO2, NOx) and CO in Kocaeli, Turkey. In the first stage, the pollutant sources classified as point, area and line sources are determined in the area. Then the annual emission rates of the pollutants released from these sources are estimated by the emission factors given by USEPA and CORINAIR.
View Article and Find Full Text PDFJ Environ Sci Health A Tox Hazard Subst Environ Eng
September 2006
Trace concentrations of a variety of chemicals remain in solid residues following combustion even in properly designed and operated incinerators. In the present study, the adsorbable organic halogen (AOX) levels of the solid residues, i.e.
View Article and Find Full Text PDFPCDD/F analyses were made in soil and ambient air samples taken from Kocaeli, an industrialized area of Turkey. Results showed that the levels of PCDD/F pollution are comparable to the levels observed in the various urban areas in the world. PCDD/F concentrations in surface soils ranged between 0.
View Article and Find Full Text PDFA multimedia risk assessment procedure was conducted to determine the fate and transport of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran (PCDD/F) emissions from the Izmit Hazardous and Medical Waste Incinerator (IZAYDAS) in Turkey and their potential health risks. Congener concentrations in ambient air and their deposition rates were determined by an air dispersion model (ISCST3). Their transfer to some plant groups and animal tissues was predicted by food chain modeling.
View Article and Find Full Text PDFA study was conducted to evaluate the health impact of airborne pollutants on incinerator workers at IZAYDAS Incinerator, Turkey. Ambient air samples were taken from two sampling points in the incinerator area and analyzed for particulate matter, heavy metals, volatile and semi-volatile organic compounds (VOCs and SVOCs) and dioxins. The places where the maximum exposure was expected to occur were selected in determining the sampling points.
View Article and Find Full Text PDFThe adsorption of polychlorinated dibenzodioxins and dibenzofurans (PCDD/Fs) by activated carbon (AC) was examined in a fixed-bed AC unit in a hazardous waste incinerator (IZAYDAS) in Turkey. Results showed that the removal efficiencies of PCDD/Fs decrease as the chlorination level increases, which was explained by the difference in gas/particle partitioning of the compounds. Since dioxins are tightly adsorbed by activated carbon, other flue gas constituents showed no clear effect on the dioxin removal.
View Article and Find Full Text PDFPartitioning of eight targeted heavy metals (Cr, Mn, Cu, Pb, Sn, Co, Ni and Zn) was carried out during five trial burns in Izmit hazardous and clinical waste incinerator (IZAYDAS). Metal contents of the original wastes and their concentration in the bottom ash (BA), fly ash (FA), filter cake (FC) and flue gas were determined. Partitioning behavior of metals during the two-stage incineration was evaluated with respect to physico-chemical properties of feed waste and metals, and the operational conditions.
View Article and Find Full Text PDF