Nihon Hoshasen Gijutsu Gakkai Zasshi
July 2023
Purpose: Late arterial phase images of SD 8, SD 10, and SD 12 were acquired in the 3-phase dynamic study of the liver in combination with hybrid iterative reconstruction. We evaluated the low-contrast detectability by adding a simulated tumor to these images and aimed to formulate a standard image quality.
Methods: We prepared images with and without signal for 60 series of 20 samples, each with 3 image quality types (total: 120 series).
Although the liver is a regenerating organ, excessive loss of liver volume (LV) can cause fatal liver failure. It is unclear whether LV is correlated with age; however, it is known that liver function decreases with age. In addition, the gender-related role of LV remains unclear.
View Article and Find Full Text PDFCurr Issues Mol Biol
September 2021
Non-small cell lung cancer (NSCLC) is an aggressive lung cancer accounting for approximately 85% of all lung cancer patients. For the patients with Stages IIIA, IIIB, and IIIC, the 5-year survival is low though with the combination with radiotherapy and chemotherapy. In addition, the occurrence of tumor cells (repopulated tumors) that survive irradiation remains a challenge.
View Article and Find Full Text PDFThe influence of sulfinate agents applied as a dentin pretreatment or a mixture with multi-mode one-step self-etch adhesives (1-SEAs) on the degree of conversion (DC) and micro-tensile bond strength (μTBS) of light-cured 1-SEAs was investigated. 1-SEAs Clearfil Universal Bond Quick (UBQ) or Scotchbond Universal Adhesive (SBU) were applied to dentin in etch&rinse or self-etch mode using various application strategies: 1) no pretreatment, 2) pretreatment with 90 wt% ethanol, 3) pretreatment with a sulfinate agent Clearfil DC Activator (UDC) or Scotchbond Universal DCA (SDC), or 4) a mixture of UBQ+UDC or SBU+SDC. μTBS was measured after 24 h.
View Article and Find Full Text PDFThe bonding performance of dental adhesives is most frequently evaluated using the micro-tensile bond strength (μTBS) test. Despite lacking evidence, peripheral specimens are often discarded to avoid regional variability. This study, therefore, examined whether μTBS to central and peripheral dentin differed.
View Article and Find Full Text PDFPurpose: To assess whether fusion 3D-CTA images can be corrected using non-rigid registration (NRR) for gastroenterology imaging.
Methods: This study included 55 patients before gastroenterology surgery who underwent preoperative 3D-CTA prior to gastroenterological surgery. We recorded the coordinate of measurement points on the arterial vessels (X, Y, and Z) in each portal phase, original image of the arterial phase, and arterial phase with NRR.
Computed tomography arterial portography (CTAP) is widely used with a fixed scan timing and contrast medium quantity; however, these parameters are not necessarily optimal. In this study, CTAP scan timing was analyzed by different bolus tracking methods to monitor the inflow of the contrast medium in real-time. A total of 249 patients who underwent CTAP were assessed.
View Article and Find Full Text PDFObjectives: To investigate the effect of light-illuminating direction (from composite or enamel side) on color adjustment at the coronal and cervical enamel borders in composite restorations.
Materials And Methods: Forty cylindrical holes (3.0-mm diameters) were prepared in bovine enamel disks (1.
Nihon Hoshasen Gijutsu Gakkai Zasshi
March 2019
Purpose: We developed a novel digital phantom-creation tool that will help formulate the standard shooting method for a three-phase dynamic liver study. Here, we present data demonstrating the usefulness of this tool in the assessment of low-contrast detectability and visibility.
Methods: We performed a visual evaluation by adding a spherical digital phantom with a diameter of 8 mm and a computed tomography (CT) value difference of 10 Hounsfield unit (HU) to images taken using filtered back projection and seven types of adaptive iterative dose reduction 3D (Weak, Mild, eMild, Standard, eStandard, Strong, and eStrong).
We evaluated the effect of different curing strategies for universal adhesives on micro-tensile bond strength (μTBS) between resin cement and dentin and/or between resin cement and indirect resin composite. Flat coronal dentin surfaces and composite resin disks were pretreated with silane-containing universal adhesives, with or without light-curing on the dentin-side and/or composite resin disk-side. Resin disks were luted onto the pretreated dentin surfaces with the corresponding dual-cure adhesive resin cements and light-cured, and cut into beams after 24-h water storage.
View Article and Find Full Text PDFThis study aimed to evaluate influence of different post-end positions in alveolar bone level on stress distributions in resin-core build-up tooth under different load directions. Three-dimensional mathematical models of a root-filled mandibular premolar tooth were constructed. Resin post and core were built-up with six post lengths: 0, 1, 2, 3, 4, and 6 mm.
View Article and Find Full Text PDFTestis-ova differentiation in sexually mature male medaka (Oryzias latipes) is easily induced by estrogenic chemicals, indicating that spermatogonia persist in sexual bipotentiality, even in mature testes in medaka. By contrast, the effects of estrogen on testicular somatic cells associated with testis-ova differentiation in medaka remain unclear. In this study, we focused on the dynamics of sex-related genes (Gsdf, Dmrt1, and Foxl2) expressed in Sertoli cells in the mature testes of adult medaka during estrogen-induced testis-ova differentiation.
View Article and Find Full Text PDFThis study aimed to investigate shear stress distributions in resin built-up teeth using resin composites of varying elastic moduli (E), with or without fiber posts. Three-dimensional mathematical models of a root-filled mandibular premolar tooth were constructed. Resin post and cores were built-up with resin composites of three different E: 12,000, 18,000 and 24,000 MPa, with or without fiber posts.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
April 2017
Preoperative three-dimensional computed tomography (3DCT) of the liver is the most important examination in performing preoperative simulation. Detailed visualization of the portal vein using the workstation is critical to enable accurate liver segmentation. However, the timing of imaging in the portal venous phase has mostly been reported equivalent to that of the liver screening examinations commonly performed.
View Article and Find Full Text PDFObjective: To determine if acid-etched, cross-linked dentin can be dehydrated without lowering bond strength below that of cross-linked wet-bonded dentin in vitro.
Methods: Using extracted human third molars, control acid-etched dentin was bonded with Single Bond Plus, using either the wet- or dry-bonding technique. Experimental acid-etched dentin was treated with 5mass% grape seed extract (GSE) in different solvents for 1min before undergoing wet vs dry resin-dentin bonding with Single Bond Plus.
The present study evaluated the effectiveness of a dicalcium and tetracalcium phosphate-based desensitizer in reducing dentin permeability in vitro. Dentin fluid flow was measured before and after treatment of dentin with patent dentinal tubules using 1 or 3 applications of the dicalcium and tetracalcium phosphate containing agent TeethmateTM (TM) and comparing the results with two sodium fluoride varnishes VellaTM (VLA) and VanishTM (VAN), after storage in artificial saliva for 24 h, 48 h and 7 days. Significant differences were observed among the 4 methods employed for reducing dentin permeability (p < 0.
View Article and Find Full Text PDFPurpose: This review describes the evolution of the use of dental adhesives to form a tight seal of freshly prepared dentin to protect the pulp from bacterial products, during the time between crown preparation and final cementation of full crowns. The evolution of these "immediate dentin sealants" follows the evolution of dental adhesives, in general. That is, they began with multiple-step, etch-and-rinse adhesives, and then switched to the use of simplified adhesives.
View Article and Find Full Text PDFObjectives: The aim of the current study was to evaluate the effect of 2% CHX and 2% CHX-methacrylate compared to the resin-dentin bonds created by a two-step etch-and-rinse adhesive system after 24h, 6min and 12min.
Methods: Microtensile bond strengths and interfacial nanoleakage within resin-dentin interfaces created by Adper Single Bond 2, with or without CHX or CHX-methacrylate pre-treatment for 30s on acid-etched dentin surfaces, were evaluated after 24h, 6min and 12min of storage in distilled water at 37°C.
Results: Twelve months of storage resulted in a significant decrease in microtensile bond strength in the control group, and significant increases in silver nanoleakage.
Purpose: To investigate whether the application of ethanol to a two-step self-etching adhesive can improve its resin-dentin bond performance.
Methods: Four different ethanol concentrations were added to the adhesive of Clearfil SE Bond to create four ethanol primers (40, 60, 80 or 100% ethanol). 24 extracted third molars were divided into four groups.
ABSTRACT The biocontrol agent Pythium oligandrum produces glycoprotein elicitor in the cell wall fraction, designated CWP, and induces resistance to a broad range of pathogens. To understand the mechanism of CWP-induced resistance to pathogens, gene expression at the early stage of CWP treatment in tomato roots was analyzed using a cDNA array. At 4 h after CWP treatment, 144 genes were up-regulated and 99 genes were down-regulated.
View Article and Find Full Text PDF