The nursing shortage, legal requirements, and funding deficits have led to increasingly poor patient care in German hospitals.Volunteer patient companions offer support by conversing with and caring for patients. This can work to relieve hospital staff while diminishing patients' fears/worries.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2022
Background: Fragility fractures of the sacrum (FFS) have been detected more and more frequently in recent times, and the incidence will continue to increase due to increasing life expectancy. The aim of this study was to compare the clinical outcome of conservative, interventional and surgical treatment of FFS.
Methods: Retrospectively, 292 patients (276 women, 16 men) with confirmed FFS were followed up over a period of 2 years.
Background: The objective of the present study on patients with fragility fractures of the sacrum (FFS) was to assess existing risk factors and clinical outcomes after cement sacroplasty (CSP).
Patients And Methods: 68 patients (64 women, 4 men) with previous FFS were followed up retrospectively. CT and MRI images were used to classify fractures according to Denis et al.
Background: Insufficiency fractures of the sacrum are being detected increasingly more frequently, whereby their incidence will no doubt increase further as a result of the rise in life expectancy.
Objective: The clinical appearance of sacral insufficiency fractures, the treatment approach taking into account the clinical outcomes and the DRG proceeds are discussed on the basis of clinical examples.
Patients And Methods: Three female patients (average age 78.
Background: Today, nearly two thirds of inpatients in trauma surgery hospitals are over 70 years old and at significant risk for comorbidities. These patients frequently suffer delirium. Delirium occurs in 15 - 30% of these trauma patients and increases the risk of mortality in up to 15 - 25% of cases.
View Article and Find Full Text PDFZ Orthop Unfall
December 2019
Demographic development in Germany has led to an aging of the population. Particularly for these patients, osteoporosis-induced vertebral fractures represent a significant decrease in quality of life and level of activity. According to current guidelines, the initial treatment of stable osteoporotic vertebral fractures is conservative management with analgesic, anti-osteoporotic, physical therapy, and orthotic measures as first line options.
View Article and Find Full Text PDFIndication: In-hospital patients with limited mobility are extremely vulnerable in cases of emergency or fire. In the past, several large fires in multi-story hospitals have resulted in deaths.
Methods: For this reason, we have developed an evacuation mattress that incorporates the functions of an evacuation towel with the comfort of a normal mattress.
Rupture of the anterior cruciate ligament (ACL) is a common sports injury. Shear forces can damage the articular cartilage and lead to early osteoarthritis. Ligamentary stabilisation of the knee is necessary.
View Article and Find Full Text PDFCement-augmented pedicle screws can increase the stability of fixators for unstable vertebral fractures in the elderly. Fixators can be inserted quickly and with minimally invasive techniques, reducing surgical risks. From March 2012 until July 2014, we treated 40 patients with percutaneous augmented fixators for unstable vertebral fractures.
View Article and Find Full Text PDFArch Trauma Res
September 2016
Background: In geriatric patients with Pauwels types II and III femoral neck fractures, hemiprosthesis is the therapy of choice.
Objectives: This study was conducted to analyze the results after cemented hemiprosthesis placement, the first year after surgery.
Patients And Methods: This retrospective study was conducted on 319 patients over 70 years with displaced femoral neck fractures treated surgically at our hospital from 2007 to 2012.
Objective: An experimental cadaver model was used to assess the effects of a malunited fracture of the middle third of the clavicle on the functional anatomy of the shoulder joint.
Method: Anatomic samples were prepared with simulated shortening and axial malposition of the clavicle. From these, alterations in glenoid fossa position were measured and depicted graphically.
This multicenter, prospective, randomized study compares the use of biodegradable polylactide pins with standard metal mini-fragment implants for the treatment of displaced radial head fractures. It compares complication rates and clinical outcomes of both treatment methods. At 2 years, 135 (82%) of 164 patients were available for evaluation.
View Article and Find Full Text PDFIntramedullary fixation is used increasingly to treat clavicular fractures. Anatomical variations in the clavicle of relevance to this procedure are analyzed. The length, diameters and curvature of the clavicle were measured in 196 specimens from the dissecting room.
View Article and Find Full Text PDFEighteen patients with intraarticular calcaneal fractures treated with open reduction and internal fixation and augmentation with an injectable carbonated apatite cement. Functional follow-up studies using the Zwipp Foot Score and densitometry were performed at 6-month intervals postoperatively. Histological samples of biopsies obtained at the time of hardware removal (6 months postoperatively) were also analyzed.
View Article and Find Full Text PDFThis prospective study investigated medium-term outcomes for 51 children treated from 1997 to 2001 for displaced diaphyseal forearm fractures with elastic stable intramedullary nailing. Forty-three patients included achieved excellent/good functional results at an average follow-up of 38 months. Four patients required open fracture-manipulation at surgery.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
November 2005
Biodegradable polylactide implants allow secure fixation of osteochondral fractures. This quasirandomized parallel-group animal study investigates whether a composite implant of poly-L/DL-lactide (PLDLLA) with additional 10% beta-tricalcium phosphate produces an osteoconductive effect, whether the admixture positively influences implant degradation (assessed by comparing time to implant degradation), and whether the pin sites of degraded implants are replaced with bone tissue. On 36 medial femoral condyles of sheep, osteotomies were fixed with either three PLDLLA pins or three composite pins.
View Article and Find Full Text PDFThe current study was designed to clarify whether biodegradable poly-L/DL lactide pins provide an operative alternative for fixation of Pipkin fractures. Nine patients with Pipkin fractures (one with Pipkin Type I, one with Pipkin Type II, and seven with Pipkin Type IV fractures) were treated surgically between 1996 and 2002. In all patients, the femoral head fractures were fixed with biodegradable, 2.
View Article and Find Full Text PDFBiodegradable polylactide implants allow secure fixation of osteochondral fractures with minimal adverse effects. The goal of this prospective, randomized animal study was to show whether osteoconductive effects can be achieved through the development of poly-L/DL(70/30)lactide composite implants with 10% beta-tricalcium phosphate, and whether degradation can be positively influenced and adverse effects minimized using such implants. An additional goal was to clarify which radiological procedure is most suitable to observe the course of follow-up.
View Article and Find Full Text PDF