Introduction: The aim of this retrospective study was to analyze the clinical and functional outcome of a modular tapered revision hip stem after mid-term follow-up with a special focus on the length of the distal bicortical fixation of the cementless hip stem.
Materials And Methods: Follow-up examination was carried out for all patients with implantation of the Prevision hip stem between 2014 and 2019 to collect demographic, functional, and radiographic data.
Results: 44 patients with stem in situ were examined, and 61 patients could be included in the Kaplan-Meier survival analysis.
The aim of this study was to assess the clinical sensitivities of the tumor markers chromogranin A (CgA), urinary 5-hydroxyindoleacetic acid (5-HIAA) and alkaline phosphatase (AP) in neuroendocrine tumors (NETs) of the GastroEnteroPancreatic-(GEP-) system depending on tumor primary location and metastatic spread. In a retrospective single-center series, sensitivities were evaluated in serum samples from 110 patients with midgut (n = 62) and pancreatic (n = 48) NETs. CgA levels were analyzed by a commercially-available immunoradiometric assay (CIS-bio) during routine follow-up in the years 2000-2009.
View Article and Find Full Text PDFBackground: Diarrhea is common in patients with Crohn's disease and may be accompanied by acid base disorders, most commonly metabolic acidosis due to intestinal loss of bicarbonate.
Case Presentation: Here, we present a case of severe metabolic alkalosis in a young patient suffering from M. Crohn.
The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12 x 0.75-mm collimation was performed in 20 patients with recurrent angina 4.
View Article and Find Full Text PDFEighty-four patients with suspected coronary artery disease were studied to determine the accuracy of noninvasive coronary angiography using a multidetector computed tomographic scanner with 64- x 0.6-mm collimation and 330-ms gantry rotation. All coronary artery segments with a diameter >1.
View Article and Find Full Text PDFWe present a performance evaluation of a recently introduced dual-source computed tomography (DSCT) system equipped with two X-ray tubes and two corresponding detectors, mounted onto the rotating gantry with an angular offset of 90 degrees . We introduce the system concept and derive its consequences and potential benefits for electrocardiograph [corrected] (ECG)-controlled cardiac CT and for general radiology applications. We evaluate both temporal and spatial resolution by means of phantom scans.
View Article and Find Full Text PDFObjectives: We sought to evaluate graft patency, flow, and flow reserve in patients with minimally invasive direct coronary artery bypass surgery of internal thoracic artery grafts by a combined magnetic resonance protocol with a phase-contrast technique and magnetic resonance angiography.
Methods: At 1.5 T (Magnetom Sonata, Siemens), 30 symptomatic patients with 30 left internal thoracic artery grafts were examined 6 years after minimally invasive surgical intervention.
Computed tomography pulmonary angiography (CTA) has increasingly become accepted as a widely available, safe, cost-effective, and accurate method for a quick and comprehensive diagnosis of acute pulmonary embolism (PE). Pulmonary catheter angiography is still considered the gold standard and final imaging method in many diagnostic algorithms. However, spiral CTA has become established as the first imaging test in clinical routine due to its high negative predictive value for clinically relevant PE.
View Article and Find Full Text PDFIn the past 2 years mechanical multidetector-row CT (MDCT) systems with simultaneous acquisition of four slices and half-second scanner rotation have become widely available. Data acquisition with these scanners allows for considerably faster coverage of the heart volume compared with single-slice scanning. This increased scan speed can be used for retrospective gating together with 1-mm collimated slice widths and allows coverage of the entire cardiac volume in one breath hold.
View Article and Find Full Text PDFTechnol Cancer Res Treat
June 2003
The aim of this study was to compare different representation models of surface-rendered virtual bronchoscopy. 10 consecutive patients with inoperable primary lung tumors underwent thin-section spiral computed tomography. The structures of interest, the tracheobronchial system and anatomical and pathological thoracic structures were segmented using an interactive threshold interval volume-growing segmentation algorithm and visualized with the aid of a color-coded surface rendering method.
View Article and Find Full Text PDFBackground: 4-slice CT scanners have shown limitations in clinical application for noninvasive coronary CT angiography (CTA). We evaluate advances in ECG-gated scanning of the heart and the coronary arteries with recently introduced 16-slice CT equipment (SOMATOM Sensation 16, Siemens, Forchheim, Germany).
Materials And Methods: The technical principles of ECG-gated cardiac scanning, scan parameters, and detector design of the new scanner are presented.
Purpose: To methodically evaluate the reproducibility and accuracy of coronary arterial calcification measurements by using spiral multi-detector row and electron-beam computed tomography (CT) with a beating heart phantom.
Materials And Methods: A phantom was built to mimic a beating heart with coronary arteries and calcified plaques. The simulated vessels moved in a pattern similar to that of a beating heart.