Purpose: To evaluate the differences in corneal wavefront measurements in myopic and hyperopic eyes when calculated using three different reference centers and explore possible influencing factors for such differences.
Methods: Corneal wavefront measurements were performed in myopic and hyperopic eyes using a GALILEI Placido Dual Scheimpflug Analyzer (Ziemer Ophthalmic Systems AG). Corneal higher order aberrations (HOAs), including total, vertical, and horizontal coma-like aberrations, spherical aberrations, and total corneal HOAs through a 6-mm pupil size, were calculated over three different reference center positions: pupil center, corneal vertex, and limbus to limbus.
Purpose: To determine the reliability of the percentage of tissue altered (PTA) calculation as part of the planning strategy for myopic laser in situ keratomileusis (LASIK) by comparing the estimated PTA provided by preoperative calculation to the postoperative PTA actually achieved in microkeratome-assisted myopic LASIK.
Methods: This retrospective study included 3,624 eyes of 3,624 patients who underwent mechanical microkeratome-assisted LASIK surgery for myopic correction. The calculated preoperative PTA values based on the planned flap thickness and ablation depth were compared with the actual achieved postoperative PTA using the difference of corneal central thickness postoperatively for assessing the achieved ablation depth and the intraoperative ultrasound-assisted flap thickness measurement.
Lens coloboma is a developmental defect resulting from abnormalities of the zonules and ciliary body. It may present as an isolated pathology or be accompanied by anomalies in different ocular structures. We report the case of a 20-year-old man referred for evaluation of anisometropic amblyopia in the right eye.
View Article and Find Full Text PDFPurpose: To evaluate the impact of a prolonged reading session on a smartphone screen on optical quality metrics and tear film stability.
Methods: This prospective study was conducted in 41 healthy volunteers who were asked to read an article on a smartphone screen for 20 minutes. The following tests were performed before the reading task in this consecutive order and repeated after the reading task in the same order: automated noninvasive tear break-up time, optical quality assessment including Objective Scatter Index (OSI), modulation transfer function, Strehl ratio, and tear film dynamic analysis as follows: vision break-up time (VBUT) as a function of OSI changes within 20 seconds, using a double-pass aberrometer imaging system, and fluorescein tear break-up time (FBUT) measured using the slit lamp.