The integration of soft robots in medical procedures has significantly improved diagnostic and therapeutic interventions, addressing safety concerns and enhancing surgeon dexterity. In conjunction with artificial intelligence, these soft robots hold the potential to expedite autonomous interventions, such as tissue palpation for cancer detection. While cameras are prevalent in surgical instruments, situations with obscured views necessitate palpation.
View Article and Find Full Text PDFUnderstanding the ability of internal- and external-infesting stored product insects to vector microbes is important for estimating the relative risk that insects pose to postharvest commodities as they move between habitat patches and in the landscape. Thus, the aim of the current study was to evaluate and compare the microbial growth in novel food patches at different dispersal periods by different populations of (e.g.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
October 2024
Tendon-sheath structures are commonly utilized to drive surgical robots due to their compact size, flexibility, and straightforward controllability. However, long-distance cable tension estimation poses a significant challenge due to its frictional characteristics affected by complicated factors. This paper proposes a miniature tension sensor array for an endoscopic cable-driven parallel robot, aiming to integrate sensors into the distal end of long and flexible surgical instruments to sense cable tension and alleviate friction between the tendon and sheath.
View Article and Find Full Text PDFSignificance: The integrity of the intestinal barrier is gaining recognition as a significant contributor to various pathophysiological conditions, including inflammatory bowel disease, celiac disease, environmental enteric dysfunction (EED), and malnutrition. EED, for example, manifests as complex structural and functional changes in the small intestine leading to increased intestinal permeability, inflammation, and reduced absorption of nutrients. Despite the importance of gut function, current techniques to assess intestinal permeability (such as endoscopic biopsies or dual sugar assays) are either highly invasive, unreliable, and/or difficult to perform in certain patient populations (e.
View Article and Find Full Text PDFThe permeability of the intestinal barrier is altered in a multitude of gastrointestinal conditions such as Crohn's and coeliac disease. However, the clinical utility of gut permeability is currently limited due to a lack of reliable diagnostic tests. To address this issue, we report a novel technique for rapid, non-invasive measurement of gut permeability based on transcutaneous ('through-the-skin') fluorescence spectroscopy.
View Article and Find Full Text PDFSelf-determination theory proposes that intrinsic aspirations protect against negative mental health outcomes by satisfying people's basic psychological needs of autonomy, relatedness, and competence. The present study investigated this relationship using two four-wave prospective longitudinal studies which followed undergraduate students across the Canadian academic calendar (September to May). The first was conducted across 2018-19 and the second across 2019-20.
View Article and Find Full Text PDFThe synthesis path of the C-Buckyball fullerene from a planar precursor developed by Scott et al. [Science, 2002, 295, 5559] is investigated with density functional theory (DFT) methods. Various theoretically possible closing paths are analysed with respect to structural and energetic properties.
View Article and Find Full Text PDFMinimally Invasive Surgery (MIS) imposes a trade-off between non-invasive access and surgical capability. Treatment of early gastric cancers over 20 mm in diameter can be achieved by performing Endoscopic Submucosal Dissection (ESD) with a flexible endoscope; however, this procedure is technically challenging, suffers from extended operation times and requires extensive training. To facilitate the ESD procedure, we have created a deployable cable driven robot that increases the surgical capabilities of the flexible endoscope while attempting to minimize the impact on the access that they offer.
View Article and Find Full Text PDFObjective: Electrical impedance tomography (EIT) is an imaging technique that produces tomographic images of internal impedance changes within an object using surface electrodes. It can be used to image the slow increase in cerebral tissue impedance that occurs over seconds during epileptic seizures, which is attributed to cell swelling due to disturbances in ion homeostasis following hypersynchronous neuronal firing and its associated metabolic demands. In this study, we characterised and imaged this slow impedance response during neocortical and hippocampal epileptiform events in the rat brain and evaluated its relationship to the underlying neural activity.
View Article and Find Full Text PDFSensors (Basel)
December 2020
Electrical Impedance Tomography (EIT) is a medical imaging technique which has the potential to reduce time to treatment in acute stroke by rapidly differentiating between ischaemic and haemorrhagic stroke. The potential of these methods has been demonstrated in simulation and phantoms, it has not yet successfully translated to clinical studies, due to high sensitivity to errors in scalp electrode mislocation and poor electrode-skin contact. To overcome these limitations, a novel electrode helmet was designed, bearing 32 independently controlled self-abrading electrodes.
View Article and Find Full Text PDFBackground: Epilepsy is a common neurological disorder affecting over 60 million people globally, approximately a third of whom are refractory to pharmacotherapy. Surgical resection of the epileptogenic zone is frequently unsuitable or ineffective, particularly for individuals with focal neocortical or mesial temporal lobe epilepsy. Therefore, there is a need to develop animal models for elucidating the mechanisms of focal epilepsies and evaluating novel treatment strategies.
View Article and Find Full Text PDFObjective: Multi-frequency symmetry difference electrical impedance tomography (MFSD-EIT) can robustly detect and identify unilateral perturbations in symmetric scenes. Here, an investigation is performed to assess if the algorithm can be successfully applied to identify the aetiology of stroke with the aid of machine learning.
Methods: Anatomically realistic four-layer finite element method models of the head based on stroke patient images are developed and used to generate EIT data over a 5 Hz-100 Hz frequency range with and without bleed and clot lesions present.
Electrical impedance tomography (EIT) is a medical imaging technique which reconstructs images of the internal impedance changes within an object using non-penetrating surface electrodes. To date, EIT has been used to image fast neural impedance changes during somatosensory evoked potentials and epileptiform discharges through the rat cerebral cortex with a resolution of 2 ms and <300 μm. However, imaging of neural activity in subcortical structures has never been achieved with this technique.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
August 2020
Objective: Bi-Frequency Symmetry Difference (BFSD)-EIT can detect, localize and identify unilateral perturbations in symmetric scenes. Here, we test the viability and robustness of BFSD-EIT in stroke diagnosis.
Methods: A realistic 4-layer Finite Element Method (FEM) head model with and without bleed and clot lesions is developed.
Background: In mammals, fast neural Electrical Impedance Tomography (EIT) can image the myelinated component of the compound action potentials (CAP) using a nerve cuff. If applied to unmyelinated fibres this has great potential to improve selective neuromodulation ("electroceuticals") to avoid off-target effects. Previously, bioimpedance recordings were averaged from unmyelinated crab leg nerve fibres, but the signal to noise ratio (SNR) needs improving.
View Article and Find Full Text PDFObjective: Electrical impedance tomography (EIT) can be used to image impedance changes which arise due to fast electrical activity during neuronal depolarisation and so holds therapeutic potential for improving the localisation of epileptic seizure foci in patients with treatment-resistant epilepsy to aid surgical resection of epileptogenic tissue. Prolonged cortical stimulation may, however, induce neural injury through excitotoxicity and electrochemical reactions at the tissue-electrode interface. The purpose of this work was to assess whether current levels used in fast neural EIT studies induce histologically detectable tissue damage when applied continuously to the rat cerebral cortex.
View Article and Find Full Text PDFObjective: Methods have previously been reported for simultaneous EIT and EEG recording, but these have relied on post-hoc signal processing to remove switching artefacts from the EEG signal and require dedicated hardware filters and the use of separate EEG and EIT electrodes. This work aims to demonstrate that an uncorrupted EEG signal can be collected simultaneously with EIT data by using frequency division multiplexing (FDM), and to show that the EIT data provides useful information when compared to EEG source localisation.
Approach: A custom FDM EIT current source was created and evaluated in resistor phantom and neonatal head tank experiments, where a static and dynamic perturbation was imaged.
Objective: A novel method for the imaging of static scenes using electrical impedance tomography (EIT) is reported with implementation and validation using numerical and phantom models. The technique is applicable to regions featuring symmetry in the normal case, asymmetry in the presence of a perturbation, and where there is a known, frequency-dependent change in the electrical conductivity of the materials in the region.
Approach: The stroke diagnostic problem is used as a motivating sample application.
Objective: Non-invasive imaging techniques are undoubtedly the ideal methods for continuous monitoring of neural activity. One such method, fast neural electrical impedance tomography (EIT) has been developed over the past decade in order to image neural action potentials with non-penetrating electrode arrays.
Approach: The goal of this study is two-fold.
Electrical Impedance Tomography (EIT) is an emerging medical imaging technique which can produce tomographic images of internal impedance changes within an object using non-penetrating surface electrodes. It has previously been used to image impedance changes due to neuronal depolarisation during evoked potentials in the rat somatosensory cortex with a resolution of 2 ms and <200 μm, using an epicortical electrode array. The purpose of this work was to use this technique to elucidate the intracortical spatiotemporal trajectory of ictal spike-and-wave discharges (SWDs), induced by electrical stimulation in an acute rat model of epilepsy, throughout the cerebral cortex.
View Article and Find Full Text PDFWe present the design of a flexible quantum-chemical method development framework, which supports employing any type of basis function. This design has been implemented in the light-weight program package molsturm, yielding a basis-function-independent self-consistent field scheme. Versatile interfaces, making use of open standards like python, mediate the integration of molsturm with existing third-party packages.
View Article and Find Full Text PDFObjective: Understanding the coding of neural activity in nerve fascicles is a high priority in computational neuroscience, electroceutical autonomic nerve stimulation and functional electrical stimulation for treatment of paraplegia. Unfortunately, it has been little studied as no technique has yet been available to permit imaging of neuronal depolarization within fascicles in peripheral nerve.
Approach: We report a novel method for achieving this, using a flexible cylindrical multi-electrode cuff placed around nerve and the new medical imaging technique of fast neural electrical impedance tomography (EIT).
Objective: Electrical impedance tomography (EIT) can be used to image impedance changes associated with epileptiform activity and so holds therapeutic potential for improving presurgical localisation of the ictal onset zone in patients with treatment-resistant epilepsy. There are two principal impedance changes which occur during seizures that may be imaged with EIT: (a) a fast, transient impedance decrease over milliseconds due to hypersynchronous neuronal depolarisation in individual ictal discharges; and (b) a larger, slow impedance increase caused by cell swelling over the course of the seizure. The magnitude of these signals is highly dependent on the carrier frequency of applied current used for obtaining impedance measurements.
View Article and Find Full Text PDFElectrical Impedance Tomography (EIT) is a non-invasive imaging technique, which has the potential to expedite the differentiation of ischaemic or haemorrhagic stroke, decreasing the time to treatment. Whilst demonstrated in simulation, there are currently no suitable imaging or classification methods which can be successfully applied to human stroke data. Development of these complex methods is hindered by a lack of quality Multi-Frequency EIT (MFEIT) data.
View Article and Find Full Text PDF