Donation after circulatory death (DCD) livers face increased risks of critical complications when preserved with static cold storage (SCS). Although machine perfusion (MP) may mitigate these risks, its cost and logistical complexity limit widespread application. We developed the Dynamic Organ Storage System (DOSS), which delivers oxygenated perfusate at 10°C with minimal electrical power requirement and allows real-time effluent sampling in a portable cooler.
View Article and Find Full Text PDFObjective: Static cold storage with ice has been the mainstay of cardiac donor preservation. Early preclinical data suggest that allograft preservation at 10 °C may be beneficial. We tested this hypothesis by using a static 10 °C storage device to preserve and transport cardiac allografts.
View Article and Find Full Text PDFBackground: Anemia is a risk factor for increased morbidity and mortality in multiple medical conditions, yet the impact of pretransplant anemia in patients with advanced lung disease on post-transplant outcomes remains under-explored. We sought to determine whether pretransplant anemia serves as a marker of altered inflammation in the host and associates with short-term outcomes following lung transplantation.
Study Design And Methods: We performed a single-center, retrospective analysis of 238 lung transplant recipients.