Publications by authors named "Aurelien Schrapp"

Background: Hyper-IgA is not a rare finding in children although its causes are less reported than hypergamma-globulinemia in other classes of immunoglobulin. However, an isolated hyper-IgA might play a role as a diagnostic marker, in particular in children with an incomplete clinical picture at disease onset.

Results: We reported the case of a 3-year-old girl hospitalized for acute abdominal symptoms and suspicion of ruptured appendicitis.

View Article and Find Full Text PDF

Up to 25% of hospitalized patients in a psychiatric department exhibit troubles linked to cannabis use. Weaning patients with psychiatric disorders off drugs of abuse requires specific care to improve their clinical outcome. The present study aims to develop a predictive model of urinary excretion of creatinine-normalized cannabinoids (U ) and to determine U thresholds corresponding to the widely used cut-offs of 20 ng/mL and 50 ng/mL for cannabinoids.

View Article and Find Full Text PDF

Stability data of toxics or drugs in gel-based or mechanical separation blood collection tubes are lacking, especially for therapeutic drug monitoring and clinical toxicology procedures. According to ISO 15189 accreditation standard, laboratories need to master the entire preanalytical process including the stability of analytes in a specific tube. Here we explored the impact of BD PST™ II and Barricor™ separator tubes on the stability of 167 therapeutic compounds and common drugs of abuse in plasma samples using LC-MS/MS.

View Article and Find Full Text PDF

Introduction: The high-sensitivity cardiac troponin T assay of Roche Diagnostics is known to have interference with high concentrations of biotin as this assay uses biotin-streptavidin binding as detection method. As studies so far have not shown if different biotin concentrations could have diverse influence on various troponin concentrations and whether interference could be removed by available protocol within corresponding turnaround time we aimed to investigate it.

Materials And Methods: Plasma samples were spiked with different concentration of biotin solution.

View Article and Find Full Text PDF

Introduction: Development of additional parameters for complete blood count has emerged in recent hematology analyzers, leading to many publications. However, few studies have been conducted on advanced RBC parameters and hemolytic anemias. We investigated the interest of Sysmex unique parameters, MicroR and HypoHe, as well as the immature fraction of reticulocytes (IRF) in combination with complete blood and reticulocyte count, for screening hereditary spherocytosis (HS) and pyruvate kinase deficiency.

View Article and Find Full Text PDF