Spectrochim Acta A Mol Biomol Spectrosc
March 2018
A new chemiluminescence (CL) detection system combined with flow injection analysis (FIA) for the determination of Pefloxacin is proposed. The determination is based on an energy transfer from Pefloxacin to terbium (III). The metal ion enhances the weak CL signal produced by the KMnO/HSO/Pefloxacin system.
View Article and Find Full Text PDFA simple, accurate, rapid, and sensitive spectrofluorimetric method for the determination of ofloxacin in urine was developed by means of first derivative matrix isopotential synchronous fluorescence spectrometry (MISF). The calibration curve was found to be linear in the concentration range 40-320 ng/mL. The method allows the determination of compound in samples with unknown background fluorescence without the need for tedious pre-separation.
View Article and Find Full Text PDFA simple luminescent methodology for the simultaneous determination of doxycycline and chlortetracycline in pharmaceutical preparations and human urine is proposed. Since the native fluorescence of both analytes is negligible, this method takes advantage of the lanthanide-sensitized luminescence, which provides increased sensitivity. Due to the strong overlapping between the luminescence spectra of both europium complexes, the use of luminescence decay curves to resolve mixtures of the analytes is proposed, particularly as these curves are more selective.
View Article and Find Full Text PDFA simple fluorescent methodology for the simultaneous determination of nabumetone and its main metabolite, 6-methoxy-2-naphthylacetic acid (6-MNA), in pharmaceutical preparations and human urine is proposed. Due to the strong overlapping between the fluorescence spectra of both analytes, the use of fluorescence decay curves to resolve their mixture is proposed, since these curves are more selective. Values of dependent instrumental variables affecting the signal-to-noise ratio were fixed using a simplex optimization procedure.
View Article and Find Full Text PDFA rapid, simple, and inexpensive spectrofluorimetric method has been proposed for the simultaneous quantification of diflunisal, salicylic acid, fenoprofen, and 6-methoxy-2-naphthylacetic acid (6MNA). First-derivative nonlinear variable-angle synchronous fluorescence spectrometry has been developed to improve the selectivity of fluorescence measurements without loss of sensitivity. It allows the simultaneous determination of different substances in a mixture from a single spectrum based on a single scan.
View Article and Find Full Text PDFCarbaryl, a modern pesticide widely used for both agricultural and non-agricultural purposes, was determined from the chemiluminescence produced in its reaction with Ce(IV) in a nitric acid medium containing rhodamine 6G as sensitizer, using flow-injection techniques. A straightforward automatic method based on measurements peak height and peak area, which are directly proportional to the carbaryl concentration, was thus developed. Calibration graphs are linear over the concentration range from 50 to 2000 ng mL(-1).
View Article and Find Full Text PDF