Publications by authors named "Aurel Neic"

Background And Objective: Data from electro-anatomical mapping (EAM) systems are playing an increasingly important role in computational modeling studies for the patient-specific calibration of digital twin models. However, data exported from commercial EAM systems are challenging to access and parse. Converting to data formats that are easily amenable to be viewed and analyzed with commonly used cardiac simulation software tools such as openCARP remains challenging.

View Article and Find Full Text PDF

Background And Objective: Simulation of cardiac electrophysiology (CEP) is an important research tool that is increasingly being adopted in industrial and clinical applications. Typical workflows for CEP simulation consist of a sequence of processing stages starting with building an anatomical model and then calibrating its electrophysiological properties to match observable data. While the calibration stages are common and generalizable, most CEP studies re-implement these steps in complex and highly variable workflows.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aims to enhance the prediction of the need for an implantable cardiac defibrillator (ICD) post-myocardial infarction by using late gadolinium enhancement (LGE) imaging combined with advanced computational modeling.
  • - Researchers analyzed 40 patients with myocardial infarction, examining the relationship between heart tissue characteristics and the subsequent need for ICD therapy, finding that certain metrics related to scar tissue complexity were highly predictive of events.
  • - Results indicated a significant correlation between specific metrics (like interface size between healthy and scarred tissue, and types of induced ventricular tachycardias) and the likelihood of requiring ICD therapy, suggesting improved risk stratification for high-risk patients.
View Article and Find Full Text PDF

To enable large trials and personalized model predictions on clinical timescales, it is imperative that models can be constructed quickly and reproducibly. First, we aimed to overcome the challenges of constructing cardiac models at scale through developing a robust, open-source pipeline for bilayer and volumetric atrial models. Second, we aimed to investigate the effects of fibres, fibrosis and model representation on fibrillatory dynamics.

View Article and Find Full Text PDF

Aims: Substrate assessment of scar-mediated ventricular tachycardia (VT) is frequently performed using late gadolinium enhancement (LGE) images. Although this provides structural information about critical pathways through the scar, assessing the vulnerability of these pathways for sustaining VT is not possible with imaging alone.This study evaluated the performance of a novel automated re-entrant pathway finding algorithm to non-invasively predict VT circuit and inducibility.

View Article and Find Full Text PDF

Introduction: Conduction system pacing (CSP), in the form of His bundle pacing (HBP) or left bundle branch pacing (LBBP), is emerging as a valuable cardiac resynchronization therapy (CRT) delivery method. However, patient selection and therapy personalization for CSP delivery remain poorly characterized. We aim to compare pacing-induced electrical synchrony during CRT, HBP, LBBP, HBP with left ventricular (LV) epicardial lead (His-optimized CRT [HOT-CRT]), and LBBP with LV epicardial lead (LBBP-optimized CRT [LOT-CRT]) in patients with different conduction disease presentations using computational modeling.

View Article and Find Full Text PDF

Biventricular endocardial (BIV-endo) pacing and left bundle pacing (LBP) are novel delivery methods for cardiac resynchronization therapy (CRT). Both pacing methods can be delivered through leadless pacing, to avoid risks associated with endocardial or transvenous leads. We used computational modelling to quantify synchrony induced by BIV-endo pacing and LBP through a leadless pacing system, and to investigate how the right-left ventricle (RV-LV) delay, RV lead location and type of left bundle capture affect response.

View Article and Find Full Text PDF

Computer models capable of representing the intrinsic personal electrophysiology (EP) of the heart are termed virtual heart technologies. When anatomy and EP are tailored to individual patients within the model, such technologies are promising clinical and industrial tools. Regardless of their vast potential, few virtual technologies simulating the entire organ-scale EP of all four-chambers of the heart have been reported and widespread clinical use is limited due to high computational costs and difficulty in validation.

View Article and Find Full Text PDF

A significant number of right bundle branch block (RBBB) patients receive cardiac resynchronization therapy (CRT), despite lack of evidence for benefit in this patient group. His bundle (HBP) and left bundle pacing (LBP) are novel CRT delivery methods, but their effect on RBBB remains understudied. We aim to compare pacing-induced electrical synchrony during conventional CRT, HBP, and LBP in RBBB patients with different conduction disturbances, and to investigate whether alternative ways of delivering LBP improve response to pacing.

View Article and Find Full Text PDF

Catheter ablation is currently the only curative treatment for scar-related ventricular tachycardias (VTs). However, not only are ablation procedures long, with relatively high risk, but success rates are punitively low, with frequent VT recurrence. Personalized in-silico approaches have the opportunity to address these limitations.

View Article and Find Full Text PDF

Background: Thresholding-based analysis of late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) can create scar maps and identify corridors that might provide a reentrant substrate for ventricular tachycardia (VT). Current recommendations use a full-width-at-half-maximum approach, effectively classifying areas with a pixel signal intensity (PSI) >40% as border zone (BZ) and >60% as core.

Objective: The purpose of this study was to investigate the impact of 4 different threshold settings on scar and corridor quantification and to correlate this with postablation VT recurrence.

View Article and Find Full Text PDF

Cardiac fiber direction is an important factor determining the propagation of electrical activity, as well as the development of mechanical force. In this article, we imaged the ventricles of several species with special attention to the intraventricular septum to determine the functional consequences of septal fiber organization. First, we identified a dual-layer organization of the fiber orientation in the intraventricular septum of ex vivo sheep hearts using diffusion tensor imaging at high field MRI.

View Article and Find Full Text PDF

Background: Computational models of the heart built from cardiac MRI and electrophysiology (EP) data have shown promise for predicting the risk of and ablation targets for myocardial infarction (MI) related ventricular tachycardia (VT), as well as to predict paced activation sequences in heart failure patients. However, most recent studies have relied on low resolution imaging data and little or no EP personalisation, which may affect the accuracy of model-based predictions.

Objective: To investigate the impact of model anatomy, MI scar morphology, and EP personalisation strategies on paced activation sequences and VT inducibility to determine the level of detail required to make accurate model-based predictions.

View Article and Find Full Text PDF

Personalized models of cardiac electrophysiology (EP) that match clinical observation with high fidelity, referred to as cardiac digital twins (CDTs), show promise as a tool for tailoring cardiac precision therapies. Building CDTs of cardiac EP relies on the ability of models to replicate the ventricular activation sequence under a broad range of conditions. Of pivotal importance is the His-Purkinje system (HPS) within the ventricles.

View Article and Find Full Text PDF

Background And Objective: Cardiac electrophysiology is a medical specialty with a long and rich tradition of computational modeling. Nevertheless, no community standard for cardiac electrophysiology simulation software has evolved yet. Here, we present the openCARP simulation environment as one solution that could foster the needs of large parts of this community.

View Article and Find Full Text PDF
Article Synopsis
  • Cardiac digital twins (CDTs) are digital replicas of patient hearts created from clinical data to improve clinical decision-making and testing of electrophysiology devices.
  • The study addresses limitations in the current CDT generation process by introducing a comprehensive parameter vector, an abstract reference frame for better model manipulation, and an efficient electrocardiogram (ECG) model for simulation.
  • The proposed workflow successfully generated high-fidelity CDTs in under 4 hours for 12 subjects, demonstrating efficiency and precision suitable for clinical application.
View Article and Find Full Text PDF

Unlabelled: In certain cardiac conduction system pathologies, like bundle branch block, block may be proximal, allowing for electrical stimulation of the more distal His bundle to most effectively restore activation. While selective stimulation of the His bundle is sought, surrounding myocardium may also be excited, resulting in nonselective pacing. The myocardium and His bundle have distinct capture thresholds, but the factors affecting whether His bundle pacing is selective or nonselective remain unelucidated.

View Article and Find Full Text PDF

A key mechanism controlling cardiac function is the electrical activation sequence of the heart's main pumping chambers termed the ventricles. As such, personalization of the ventricular activation sequences is of pivotal importance for the clinical utility of computational models of cardiac electrophysiology. However, a direct observation of the activation sequence throughout the ventricular volume is virtually impossible.

View Article and Find Full Text PDF

Advanced cardiac modeling studies rely on the ability to generate and functionalize personalized models from tomographic multi-label image stacks. Eventually, this is used for building virtual cohorts that capture the variability in size, shape, and morphology of individual hearts. Typical modeling workflows involve a multitude of interactive mesh manipulation steps, rendering model generation expensive.

View Article and Find Full Text PDF

Background: His-bundle pacing (HBP) and left bundle pacing (LBP) are emerging as novel delivery methods for cardiac resynchronization therapy (CRT) in heart failure patients with left bundle branch block (LBBB). HBP and LBP have never been compared to biventricular endocardial (BiV-endo) pacing. Furthermore, there are indications of negative effects of LBP on right ventricular (RV) activation times (ATs), but these effects have not been quantified.

View Article and Find Full Text PDF

Computational models of the heart are increasingly being used in the development of devices, patient diagnosis and therapy guidance. While software techniques have been developed for simulating single hearts, there remain significant challenges in simulating cohorts of virtual hearts from multiple patients. To facilitate the development of new simulation and model analysis techniques by groups without direct access to medical data, image analysis techniques and meshing tools, we have created the first publicly available virtual cohort of twenty-four four-chamber hearts.

View Article and Find Full Text PDF

Background: Epicardial pacing increases risk of ventricular tachycardia (VT) in patients with ischemic cardiomyopathy (ICM) when pacing in proximity to scar. Endocardial pacing may be less arrhythmogenic as it preserves the physiological sequences of activation and repolarization.

Objective: The purpose of this study was to determine the relative arrhythmogenic risk of endocardial compared to epicardial pacing, and the role of the transmural gradient of action potential duration (APD) and pacing location relative to scar on arrhythmogenic risk during endocardial pacing.

View Article and Find Full Text PDF

The left atrium (LA) has a complex anatomy with heterogeneous wall thickness and curvature. The anatomy plays an important role in determining local wall stress; however, the relative contribution of wall thickness and curvature in determining wall stress in the LA is unknown. We have developed electromechanical finite element (FE) models of the LA using patient-specific anatomical FE meshes with rule-based myofiber directions.

View Article and Find Full Text PDF

In this study we propose a novel method for identifying the locations of earliest activation in the human left ventricle from activation maps measured at the epicardial surface. Electrical activation is modeled based on the viscous Eikonal equation. The sites of earliest activation are identified by solving a minimization problem.

View Article and Find Full Text PDF

Implanted cardiac defibrillators (ICDs) seek to automatically detect and terminate potentially lethal ventricular arrhythmias by applying strong internal electric shocks across the heart. However, the optimisation of the specific electrode design and configurations represents an intensive area of research in the pursuit of reduced shock strengths and fewer device complications and risks. Computational whole-torso simulations play an important role in this endeavour, although knowing which specific metric should be used to assess configuration efficacy and assessing the impact of different patient anatomies and pathologies, and the corresponding effect this may have on different metrics has not been investigated.

View Article and Find Full Text PDF