Purpose: The purpose of this study was to evaluate the efficacy of needle holders in reducing staff hand exposure during biopsies guided by computed tomography fluoroscopy (CTF), through the analysis of data acquired during a detailed monitoring study, undertaken in parallel with an ongoing optimization process to reduce hand irradiation.
Methods: Hand monitoring was performed with 11 extremity detectors, two per finger (base and tip) and one on the back of the wrist, for the left (dominant) hand, during two series of biopsies with comparable characteristics. The first series (47 biopsies) were performed with only quick-check method (QC) and occasional side-handle (SH) manipulation of the needle.
Computed tomography fluoroscopy (CTF) is a useful imaging technique to guide biopsies, particularly lung biopsies, but it also has the potential for very high hand exposures, despite use of quick-check method and needle holders whenever feasible. Therefore, reliable monitoring is crucial to ensure the safe use of CTF. This is a challenge, because ring dosimeters monitor exposure only at the base of one finger, while the fingertips may be exposed to the highly collimated CT beam.