Publications by authors named "Audrey K Nebergall"

Background: The objective of this 13-year prospective evaluation of highly cross-linked ultra high molecular weight polyethylene (HXLPE) was to (1) assess the long-term wear of HXLPE articulating with 2 femoral head sizes using radiostereometric analysis (RSA) and to (2) determine if osteolysis is a concern with this material through the use of plain radiographs and computerized tomography (CT).

Methods: All patients received a Longevity HXLPE liner with tantalum beads and either a 28-mm or 36-mm femoral head. Twelve patients (6 in each head size group) agreed to return for 13-year RSA, plain radiograph, and CT follow-up.

View Article and Find Full Text PDF

Background: The objective of this study was to assess the retentive rim of retrieved dual mobility liners for visible evidence of deformation from femoral neck contact and to use cadaver models to determine if anterior soft tissue impingement could contribute to such deformation.

Methods: Fifteen surgically retrieved polyethylene liners were assessed for evidence of rim deformation. The average time in vivo was 31.

View Article and Find Full Text PDF

Background: Vitamin E-diffused highly cross-linked polyethylene (VEPE) was developed to reduce oxidation without compromising mechanical strength. The purpose of this study was to evaluate VEPE in vivo using radiostereometric analysis (RSA) and patient-reported outcome measures (PROMs).

Methods: Fifty-one hips were enrolled.

View Article and Find Full Text PDF

Background: The objective of this 5-year prospective study of 51 hips was to assess migration of a cementless tapered femoral stem using radiostereometric analysis (RSA), plain radiographs (radiolucencies), and patient-reported outcome measures (PROMs).

Methods: Forty-seven patients (51 hips) agreed to participate in this prospective RSA study. All patients received a Taperloc stem.

View Article and Find Full Text PDF

Purpose: Preclinical studies of vitamin E diffused highly cross-linked polyethylene (E-XLPE) has shown enhanced mechanical properties with less wear. The purpose of our study was to document the early clinical outcome of E-XLPE to ensure, for the safety of patients, that there are no unforeseen early adverse events from using this new biomaterial.

Methods: The enrolled patients (n = 977) have received either a porous titanium coated or porous plasma sprayed acetabular shell with either a E-XLPE liner or a medium cross-linked (AXL) liner.

View Article and Find Full Text PDF

Aseptic glenoid component loosening is a common cause of total shoulder arthroplasty (TSA) failure, but early detection is difficult because pain often appears late and radiolucent lines are of uncertain significance. This study sought to answer the following questions: (1) What types of glenoid component motion may be observed during the first 3 years following implantation?; (2) Is the appearance of radiolucent lines around the glenoid component a reliable indicator of component motion?; and (3) Are clinical outcomes correlated with early glenoid component motion within the first 3 years after TSA? Eleven patients (mean age, 60.6 years) underwent TSA using a cemented, all-polyethylene glenoid component with tantalum bead implantation.

View Article and Find Full Text PDF

Background And Purpose: In traditional radiostereometric analysis (RSA), 1 segment defines both the acetabular shell and the polyethylene liner. However, inserting beads into the polyethylene liner permits employment of the shell and liner as 2 separate segments, enabling distinct analysis of the precision of 3 measurement methods in determining femoral head penetration and shell migration.

Patients And Methods: The UmRSA program was used to analyze the double examinations of 51 hips to determine if there was a difference in using the shell-only segment, the liner-only segment, or the shell + liner segment to measure wear and acetabular cup stability.

View Article and Find Full Text PDF

Vitamin E diffusion into highly cross-linked polyethylene (E-XLPE) is a method for enhancing oxidative stability of acetabular liners. The purpose of this study was to evaluate in vivo penetration of E-XLPE using radiostereometric analysis (RSA). Eighty-four hips were recruited into a prospective 10-year RSA.

View Article and Find Full Text PDF