Diisocyanates are occupational contaminants and known sensitizers causing irritation (skin and respiratory tract) as well as occupational asthma. Because of their physicochemical properties (semi-volatile and high reactivity) and low occupational limits, diisocyanate exposure evaluation is still a challenge nowadays for industrial hygienists and laboratories. The objective of this study was to compare the methylene diphenyl diisocyanate (MDI) concentrations measured by five methods using different collection or derivatization approaches in an oriented-strand board (OSB) factory.
View Article and Find Full Text PDFBecause of the semi-volatile nature of diisocyanates (being airborne in both physical vapor and particulate phases), their high reactivity and low occupational exposure limits, diisocyanate exposure evaluation has been challenging for industrial hygienists and laboratories. The objective of this study was to compare the toluene diisocyanate (2,4 and 2,6 isomers, TDI) concentration measured by five methods in a flexible polyurethane foam factory using different collection or derivatization approaches. The methods used were: OSHA 42 modified (filter, 1-(2-pyridyl)piperazine) (OSHA), Asset EZ4-NCO (denuder and filter, dibutylamine) (Asset), Iso-Chek (double-filter, 9-(N-methylaminomethyl) anthracene and 1,2-methoxyphenylpiperazine), DAN (filter, 1,8-diaminonaphthalene), and CIP10 (centrifugation, 1,2-methoxyphenylpiperazine).
View Article and Find Full Text PDF