Background: The factors influencing return to work (RTW) after primary total hip arthroplasty (THA) remain a topic of debate. Understanding these factors is essential for optimizing postoperative recovery and patient counseling. This study aims to determine whether socio-professional status and clinical factors significantly influence the timing of RTW following elective hip replacement.
View Article and Find Full Text PDFPurpose: To analyze retinal perfusion (RP) using ultrawide-field fluorescein angiography (UWFA) and optical coherence tomography angiography (OCTA), in patients with central retinal vein occlusion (CRVO) treated by intravitreal injection of aflibercept.
Methods: Single-arm, multicenter, prospective, observational study. Treatment-naive eyes with CRVO initiated therapy with aflibercept.
Orthop Traumatol Surg Res
January 2025
Introduction: Spinopelvic kinematics, reflected by the change in spinopelvic tilt (ΔSPT) from a standing position to a flexed seated position, has been associated with the risk of prosthetic impingement and hip dislocation. Some studies have suggested changes in spinopelvic mobility after total hip arthroplasty (THA), but none have explored changes in mobility in the first three months following THA using a direct anterior approach.
Hypothesis: Our hypothesis was that changes in spinopelvic mobility occur in the first 3 months postoperatively, leading to increased hip mobility and increased spinopelvic kinematic abnormalities.
Background: The EyeCee ONE intraocular lens (Nidek, Gamagori, Japan) has been withdrawn from the market due to a high number of reports of severe ocular hypertension (OHT) following phacoemulsification with implantation of this intraocular lens (IOL). In this case series, we report the results of a toxicological analysis and the surgical management of five patients with severe OHT following the implantation of defective EyeCee ONE IOLs during cataract surgery.
Cases Presentation: Five patients developed early, severe OHT refractory to maximal medical therapy following uneventful phacoemulsification (PCE) cataract surgery with implantation of an EyeCee ONE IOL from a defective lot.
The anatomy and vasculature of the optic nerve head are complex and subject to numerous variations. The main risk factor for glaucomatous optic neuropathy is elevated intraocular pressure, but many other factors have been identified. A vascular component seems to play an important role in the pathogenesis and/or progression of glaucomatous optic neuropathy, either under the influence of ocular hypertension or as an independent risk factor, particularly as in normal tension glaucoma (NTG).
View Article and Find Full Text PDFControlling the structure and functionality of porous silica nanoparticles has been a continuous source of innovation with important potential for advanced biomedical applications. Their synthesis, however, usually involves passive surfactants or amphiphilic copolymers that do not add value to the material after synthesis. In contrast, polyion complex (PIC) micelles based on hydrophilic block copolymers allow for the direct synthesis of intrinsically functional hybrid materials.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
October 2024
Introduction: The position of the pelvis in the sagittal plane can vary considerably between different functional positions. Adapting the position of the acetabular cup in relation to the alignment between the spine and the hip of each individual, prior to prosthesis placement, can prevent the risk of prosthetic impingement. Taken individually, risk factors for unfavorable spinopelvic kinematics can be difficult to interpret when trying to precisely predict which patients are at risk.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
October 2024
Introduction: Various computer-assisted surgical systems claim to improve the accuracy of cup placement in total hip arthroplasties after assessing spinopelvic mobility to prevent prosthetic impingement. However, no study has yet analyzed the extent of the patient-specific cup anteversion safe zones.
Hypothesis: We hypothesized that most patients have a safe zone >10 °, except those with abnormal spinopelvic mobility, who have a much narrower safe zone.
Background: Restoring hip anatomy during total hip arthroplasty (THA) is the gold standard. The general goal is for hips to be symmetrical in terms of height. This study aimed to analyse the effect of simulating hip length (HL) equalisation on leg-length difference (LLD) before and after THA with a computerised plan.
View Article and Find Full Text PDFBackground: An important aspect of preoperative planning for total hip arthroplasty is templating. Although two-dimensional (2D) templating remains the gold standard, computerized tomography (CT)-based three-dimensional (3D) templating is a novel preoperative planning technique. This study aims to compare the accuracy of a 2D and 3D plan using an anterior approach for the placement of the same uncemented prosthesis.
View Article and Find Full Text PDFOral delivery, while a highly desirable form of nanoparticle-drug administration, is limited by challenges associated with overcoming several biological barriers. Here, the authors study how fluorescent and poly(ethylene glycol)-coated (PEGylated) core-shell silica nanoparticles sized 5 to 50 nm interact with major barriers including intestinal mucus, intestinal epithelium, and stomach acid. From imaging fluorescence correlation spectroscopy studies using quasi-total internal reflection fluorescence microscopy, diffusion of nanoparticles through highly scattering mucus is progressively hindered above a critical hydrodynamic size around 20 nm.
View Article and Find Full Text PDFAims: The risk factors for abnormal spinopelvic mobility (SPM), defined as an anterior rotation of the spinopelvic tilt (∆SPT) ≥ 20° in a flexed-seated position, have been described. The implication of pelvic incidence (PI) is unclear, and the concept of lumbar lordosis (LL) based on anatomical limits may be erroneous. The distribution of LL, including a unusual shape in patients with a high lordosis, a low pelvic incidence, and an anteverted pelvis seems more relevant.
View Article and Find Full Text PDFBackground: Surgical site infection is a serious complication in orthopedic surgery. The use of antibiotic prophylaxis (AP) combined with other prevention strategies has been shown to reduce this risk to 1% for hip arthroplasty and 2% for knee arthroplasty. The French Society of Anesthesia and Intensive Care Medicine (SFAR) recommends doubling the dose when the patient's weight is greater than or equal to 100 kg, and the body mass index (BMI) is greater than or equal to 35 kg/m.
View Article and Find Full Text PDFPurpose: Although rare, fractures of ceramic components are difficult to revise, mainly due to the presence of residual ceramic debris that can cause catastrophic wear of the replacement components. Modern ceramic-on-ceramic bearings are suggested to improve outcomes of revision total hip arthroplasty (THA) for ceramic fractures. However, there are few published reports of mid-term outcomes of revision THA using ceramic-on-ceramic bearings.
View Article and Find Full Text PDFACS Appl Mater Interfaces
February 2023
For their unique optical properties, quantum dots (QDs) have been extensively used as light emitters in a number of photonic and optoelectronic applications. They even met commercialization success through their implementation in high-end displays with unmatched brightness and color rendering. For such applications, however, QDs must be shielded from oxygen and water vapor, which are known to degrade their optical properties over time.
View Article and Find Full Text PDFIn this paper, we studied the role of the crystal structure in spheroidal CdSe nanocrystals on the band-edge exciton fine structure. Ensembles of zinc blende and wurtzite CdSe nanocrystals are investigated experimentally by two optical techniques: fluorescence line narrowing (FLN) and time-resolved photoluminescence. We argue that the zero-phonon line evaluated by the FLN technique gives the ensemble-averaged energy splitting between the lowest bright and dark exciton states, while the activation energy from the temperature-dependent photoluminescence decay is smaller and corresponds to the energy of an acoustic phonon.
View Article and Find Full Text PDFPurpose: The lens-iris diaphragm retropulsion syndrome (LIDRS) corresponds to an acute deepening of the anterior chamber during phacoemulsification. LIDRS is painful for the patient and sometimes causes intraoperative complications. This study was designed to assess the preoperative risk factors of LIDRS and its outcome.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
April 2023
Purpose: The literature suggests that "forgotten" knees are the most stable knees postoperatively. The main objective of our study was to determine whether a systematic alignment (mechanical, anatomical or kinematic) makes it possible to stabilise the operated joint in extension and in flexion.
Methods: This monocentric prospective cohort study was conducted between May 1st, 2021 and October 31st, 2021.
Introduction: In recent years, different alignments have been described for acetabular components in total hip arthroplasty (THA), to reduce the risk of impingement and edge loading. Currently there are 3 main options: mechanical (40° inclination/15° anteversion relative to the anterior pelvic plane), anatomic (40° inclination/anteversion parallel to the transverse ligament) and combined kinematic (according to spinal-pelvic parameters). There are no studies comparing all three in terms of impingement and edge loading.
View Article and Find Full Text PDFBackground: Femorotomy is a commonly used technique during cementless stem removal but should be preferred in selective revision cases to prevent intraoperative femoral fracture associated with deteriorated clinical outcome. Our aim was to assess the risk factors for fracture or femorotomy and develop a predictive risk stratification score.
Methods: A monocentric retrospective cohort including 202 patients was analyzed.
Colloidal quantum dots (QDs) are excellent optical gain materials that combine high material gain, a strong absorption of pump light, stability under strong light exposure and a suitability for solution-based processing. The integration of QDs in laser cavities that fully exploit the potential of these emerging optical materials remains, however, a challenge. In this work, we report on a vertical cavity surface emitting laser, which consists of a thin film of QDs embedded between two layers of polymerized chiral liquid crystal.
View Article and Find Full Text PDFWhile initial theories on quantum confinement in colloidal quantum dots (QDs) led to analytical band gap/size relations or sizing functions, numerical methods describe size quantization more accurately. However, because of the lack of reliable sizing functions, researchers fit experimental band gap/size data sets using models with redundant, physically meaningless parameters that break down upon extrapolation. Here, we propose a new sizing function based on a proportional correction for nonparabolic bands.
View Article and Find Full Text PDFIntroduction: A unique type of both-column fracture of the acetabulum that also has an independent roof fragment seems to occur relatively often. It is challenging to diagnose, thus our ability to detect it and its frequency are not known. This led us to analyze a database of acetabular fractures to 1) determine the incidence of this type of fracture, 2) describe its radiological characteristics, 3) attempt to set out a specific treatment strategy.
View Article and Find Full Text PDF