Background: Deriving population specific reference intervals (RIs) or at the very least verifying any RI before adoption is good laboratory practice. Siemens has provided RIs for thyroid stimulating hormone (TSH) and free thyroxine (FT4) determined on their Atellica® IM analyzer for all age groups except the neonatal age group which provides a challenge for laboratories that intend to use it to screen for congenital hypothyroidism (CH) and other thyroid disorders in neonates. We set out to determine RIs for TSH and FT4 using data obtained from neonates undergoing routine screening for CH at the Aga Khan University Hospital, Nairobi, Kenya.
View Article and Find Full Text PDFBackground: Iron deficiency is the commonest cause of anaemia worldwide. Serum ferritin is the most sensitive non-invasive indicator of iron stores but its utility is compromised in inflammatory states as it is an acute phase reactant. This study sought to estimate the burden of iron deficiency in a healthy adult population residing in Kenya and to determine the association between various ferritin cut-offs and anaemia in a population known to have chronic low-grade inflammation.