Aptamers have emerged as prominent ligands in clinical diagnostics because they provide various advantages over antibodies, such as quicker generation time, reduced manufacturing costs, minimal batch-to-batch variability, greater modifiability, and improved thermal stability. In the present study, we isolated and characterized DNA aptamers that can specifically bind to the hemolysin E (HlyE) antigen of Salmonella Typhi for future development of typhoid diagnostic tests. The DNA aptamers against Salmonella Typhi HlyE were isolated using systematic evolution of ligands by exponential enrichment (SELEX), and their binding affinity and specificity were assessed utilizing enzyme-linked oligonucleotide assay (ELONA).
View Article and Find Full Text PDFA highly accurate, rapid, portable, and robust platform for detecting serovar Typhi ( Typhi) is crucial for early-stage diagnosis of typhoid to avert and control the outbreaks of this pathogen, which threaten global public health. This study presents a proof-of-concept for our developed label-free electrochemical DNA biosensor system for Typhi detection, which employs a printed circuit board gold electrode (PCBGE), integrated with a portable potentiostat reader. Initially, the functionalized DNA biosensor and target detection were characterized using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS) methods using a benchtop potentiostat.
View Article and Find Full Text PDFInkjet-printable ink formulated with graphene oxide (GO) offers several advantages, including aqueous dispersion, low cost, and environmentally friendly production. However, water-based GO ink encounters challenges such as high surface tension, low wetting properties, and reduced ink stability over prolonged storage time. Alkali lignin, a natural surfactant, is promising in improving GO ink's stability, wettability, and printing characteristics.
View Article and Find Full Text PDFWearable technology, such as electronic components integrated into clothing or worn as accessories, is becoming increasingly prevalent in fields like healthcare and biomedical monitoring. These devices allow for continuous monitoring of important biomarkers for medical diagnosis, monitoring of physiological health, and evaluation. However, an open-source wearable potentiostat is a relatively new technology that still faces several design limitations such as short battery lifetime, bulky size, heavy weight, and the requirement for a wire for data transmission, which affects comfortability during long periods of measurement.
View Article and Find Full Text PDFBackground: Brain cooling therapy is one of the subjects of interest, and currently, data on direct brain cooling are lacking. Hence, the objective is to investigate the clinical outcomes and discuss the thermodynamics aspect of direct brain cooling on severely injured brain patients.
Methods: This pilot study recruited the severely injured brain patients who were then randomized to either a direct brain cooling therapy group using a constant cooling temperature system or a control group.
High electron mobility transistor (HEMT) biosensors hold great potential for realizing label-free, real-time, and direct detection. Owing to their unique properties of two-dimensional electron gas (2DEG), HEMT biosensors have the ability to amplify current changes pertinent to potential changes with the introduction of any biomolecules, making them highly surface charge sensitive. This review discusses the recent advances in the use of AlGaN/GaN and AlGaAs/GaAs HEMT as biosensors in the context of different gate architectures.
View Article and Find Full Text PDFThe emergence of coronavirus disease 2019 (COVID-19) motivates continuous efforts to develop robust and accurate diagnostic tests to detect severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). Detection of viral nucleic acids provides the highest sensitivity and selectivity for diagnosing early and asymptomatic infection because the human immune system may not be active at this stage. Therefore, this work aims to develop a label-free electrochemical DNA biosensor for SARS-CoV-2 detection using a printed circuit board-based gold substrate (PCBGE).
View Article and Find Full Text PDFThe emergence of gallium nitride high-electron-mobility transistor (GaN HEMT) devices has the potential to deliver high power and high frequency with performances surpassing mainstream silicon and other advanced semiconductor field-effect transistor (FET) technologies. Nevertheless, HEMT devices suffer from certain parasitic and reliability concerns that limit their performance. This paper aims to review the latest experimental evidence regarding HEMT technologies on the parasitic issues that affect aluminum gallium nitride (AlGaN)/GaN HEMTs.
View Article and Find Full Text PDFThe development of rapid, accurate, and efficient detection methods for Salmonella can significantly control the outbreak of salmonellosis that threatens global public health. Despite the high sensitivity and specificity of the microbiological, nucleic-acid, and immunological-based methods, they are impractical for detecting samples outside of the laboratory due to the requirement for skilled individuals and sophisticated bench-top equipment. Ideally, an electrochemical biosensor could overcome the limitations of these detection methods since it offers simplicity for the detection process, on-site quantitative analysis, rapid detection time, high sensitivity, and portability.
View Article and Find Full Text PDFRecently, there has been increasing interest in electrochemical printed sensors for a wide range of applications such as biomedical, pharmaceutical, food safety, and environmental fields. A major challenge is to obtain selective, sensitive, and reliable sensing platforms that can meet the stringent performance requirements of these application areas. Two-dimensional (2D) nanomaterials advances have accelerated the performance of electrochemical sensors towards more practical approaches.
View Article and Find Full Text PDFSweat analysis offers non-invasive real-time on-body measurement for wearable sensors. However, there are still gaps in current developed sweat-sensing devices (SSDs) regarding the concerns of mixing fresh and old sweat and real-time measurement, which are the requirements to ensure accurate the measurement of wearable devices. This review paper discusses these limitations by aiding model designs, features, performance, and the device operation for exploring the SSDs used in different sweat collection tools, focusing on continuous and non-continuous flow sweat analysis.
View Article and Find Full Text PDFFace recognition is one of the most sophisticated disciplines of biometric systems. The use of VCSEL in automotive applications is one of the most recent advances. The existing VCSEL package with a diffuser on top of a lens intended for automotive applications could not satisfy the criteria of the automotive TS16949: 2009 specification because the package was harmed and developed a lens fracture during 100 thermal cycle tests.
View Article and Find Full Text PDFThe development of precise and efficient diagnostic tools enables early treatment and proper isolation of infected individuals, hence limiting the spread of coronavirus disease 2019 (COVID-19). The standard diagnostic tests used by healthcare workers to diagnose severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection have some limitations, including longer detection time, the need for qualified individuals, and the use of sophisticated bench-top equipment, which limit their use for rapid SARS-CoV-2 assessment. Advances in sensor technology have renewed the interest in electrochemical biosensors miniaturization, which provide improved diagnostic qualities such as rapid response, simplicity of operation, portability, and readiness for on-site screening of infection.
View Article and Find Full Text PDFMicromachines (Basel)
January 2022
In this present work, we aim to improve the hydrophobicity of a polydimethylsiloxane (PDMS) surface. Various heights of 3D PDMS micropillars were fabricated via grayscale photolithography, and improved wettability was investigated. Two approaches of PDMS replication were demonstrated, both using a single master mold to obtain the micropillar arrays.
View Article and Find Full Text PDFHeavy metal pollution remains a major concern for the public today, in line with the growing population and global industrialization. Heavy metal ion (HMI) is a threat to human and environmental safety, even at low concentrations, thus rapid and continuous HMI monitoring is essential. Among the sensors available for HMI detection, the field-effect transistor (FET) sensor demonstrates promising potential for fast and real-time detection.
View Article and Find Full Text PDFTyphoid fever, also known as typhoid, is a life-threatening bacterial infection that remains a global health concern. The infection is associated with a significant morbidity and mortality rate, resulting in an urgent need for specific and rapid detection tests to aid prevention and management of the disease. The present review aims to assess the specificity and sensitivity of the available literature on the immunodiagnostics of typhoid fever.
View Article and Find Full Text PDFLarge-scale food-borne outbreaks caused by are rarely seen nowadays, thanks to the advanced nature of the medical system. However, small, localised outbreaks in certain regions still exist and could possess a huge threat to the public health if eradication measure is not initiated. This review discusses the progress of detection approaches covering their basic principles, characteristics, applications, and performances.
View Article and Find Full Text PDFIn acoustic receiver design, the receiving sensitivity and bandwidth are two primary parameters that determine the performance of a device. The trade-off between sensitivity and bandwidth makes the design very challenging, meaning it needs to be fine-tuned to suit specific applications. The ability to design a PMUT with high receiving sensitivity and a wide bandwidth is crucial to allow a wide spectrum of transmitted frequencies to be efficiently received.
View Article and Find Full Text PDFNon-structural protein 1 (NS1 protein) is becoming a commonplace biomarker for the diagnostic of early detection of dengue. In this study, we sought to use a label-free approach of detecting NS1 protein by harnessing fluidic-based memristor sensor. The sensor was fabricated using sol-gel spin coating technique, by which TiO thin film is coated on the surface of Indium tin oxide (ITO) and a glass substrate.
View Article and Find Full Text PDFThree-dimensional (3D) microstructures have been exploited in various applications of microfluidic devices. Multilevel structures in micromixers are among the essential structures in microfluidic devices that exploit 3D microstructures for different tasks. The efficiency of the micromixing process is thus crucial, as it affects the overall performance of a microfluidic device.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2018
A 3.3 V CMOS bandgap reference (BGR) was presented in this study that utilizes MOS transistors operating in the sub-threshold region. The complexity of the circuit and the dependency of the voltage reference on power supply variations are simultaneously decreased through the use of a new compensation circuit technique.
View Article and Find Full Text PDFCombination of high-mean free path and scaling ability makes graphene nanoribbon (GNR) attractive for application of field-effect transistors and subject of intense research. Here, we study its behaviour at high bias near and after electrical breakdown. Theoretical modelling, Monte Carlo simulation, and experimental approaches are used to calculate net generation rate, ionization coefficient, current, and finally breakdown voltage (BV).
View Article and Find Full Text PDF