Background: The modified Rankin Scale (mRS) is a clinician-reported scale that measures the degree of disability in patients who suffered a stroke. Patients' perception of a meaningful recovery from severe stroke, expected value of a stroke intervention, and the effect of disparities are largely unknown.
Methods: We conducted a survey of patients, their family members, and accompanying visitors to understand their personal preferences and expectations for acute strokes potentially eligible for acute endovascular intervention using a hypothetical scenario of a severe stroke in a standardized questionnaire.
Diffuse Correlation Spectroscopy (DCS) is a widely used non-invasive measurement technique to quantitatively measure deep tissue blood flow. Conventional implementations of DCS use expensive single photon counters as detecting elements and optical probes with bulky fiber optic cables. In recent years, newer approaches to blood flow measurement such as Diffuse Speckle Contrast Analysis (DSCA) and Speckle Contrast Optical Spectroscopy (SCOS), have adapted speckle contrast analysis methods to simplify deep tissue blood flow measurements using cameras and single photon counting avalanche detector arrays as detectors.
View Article and Find Full Text PDFBackground: Diffuse correlation spectroscopy (DCS) is a non-invasive optical technique that enables continuous blood flow measurements in various organs, including the brain. DCS quantitatively measures blood flow from temporal fluctuations in the intensity of diffusely reflected light caused by the dynamic scattering of light from moving red blood cells within the tissue.
Methods: We performed bilateral cerebral blood flow (CBF) measurements using a custom DCS device in patients undergoing neuroendovascular interventions for acute ischemic stroke.
Dynamic cerebral autoregulation (dCA) can be derived from spontaneous oscillations in arterial blood pressure (ABP) and cerebral blood flow (CBF). Transcranial Doppler (TCD) measures CBF-velocity and is commonly used to assess dCA. Diffuse correlation spectroscopy (DCS) is a promising optical technique for non-invasive CBF monitoring, so here we aimed to validate DCS as a tool for quantifying dCA.
View Article and Find Full Text PDFDiffuse Correlation Spectroscopy (DCS), a noninvasive optical technique, measures deep tissue blood flow using avalanche photon counting modules and data acquisition devices such as FPGAs or correlator boards. Conventional DCS instruments use in-processor counter modules that consume 32 bits/channel which is inefficient for low-photon budget situations prevalent in diffuse optics. Scaling these photon counters for large-scale imaging applications is difficult due to bandwidth and processing time considerations.
View Article and Find Full Text PDFSignificance: Cerebral metabolic rate of oxygen ( ) consumption is a key physiological variable that characterizes brain metabolism in a steady state and during functional activation.
Aim: We aim to develop a minimally invasive optical technique for real-time measurement of concurrently with cerebral blood flow (CBF).
Approach: We used a pair of macromolecular phosphorescent probes with nonoverlapping optical spectra, which were localized in the intra- and extravascular compartments of the brain tissue, thus providing a readout of oxygen gradients between these two compartments.
Significance: Rapid estimation of the depth and margins of fluorescence targets buried below the tissue surface could improve upon current image-guided surgery techniques for tumor resection.
Aim: We describe algorithms and instrumentation that permit rapid estimation of the depth and transverse margins of fluorescence target(s) in turbid media; the work aims to introduce, experimentally demonstrate, and characterize the methodology.
Approach: Spatial frequency domain fluorescence diffuse optical tomography (SFD-FDOT) technique is adapted for rapid and computationally inexpensive estimation of fluorophore target depth and lateral margins.
Quantitative measurements of cerebral hemodynamic changes due to functional activation are widely accomplished with commercial continuous wave (CW-NIRS) instruments despite the availability of the more rigorous multi-distance frequency domain (FD-NIRS) approach. A direct comparison of the two approaches to functional near-infrared spectroscopy can help in the interpretation of optical data and guide implementations of diffuse optical instruments for measuring functional activation. We explore the differences between CW-NIRS and multi-distance FD-NIRS by comparing measurements of functional activation in the human auditory cortex.
View Article and Find Full Text PDFDiffuse correlation spectroscopy (DCS), a popular optical technique for fast noninvasive measurement of blood flow, is commonly implemented using expensive fiber-coupled long coherence length laser systems. Here, we report the development of a portable and fiber-less approach that can be used as a low-cost alternative to illuminate tissue in DCS instruments. We validate the accuracy and noise characteristics of the fiber-less DCS laser source, by comparisons against traditional DCS light sources, with experiments on controlled tissue-simulating phantoms and in humans.
View Article and Find Full Text PDFJ Stroke Cerebrovasc Dis
November 2019
Goals: We quantified cerebral blood flow response to a 500 cc bolus of 0.9%% normal saline (NS) within 96 hours of acute ischemic stroke (AIS) using diffuse correlation spectroscopy (DCS).
Materials And Methods: Subjects with AIS in the anterior, middle, or posterior cerebral artery territory were enrolled within 96 hours of symptom onset.
The prevention and treatment of spinal cord injury are focused upon the maintenance of spinal cord blood flow, yet no technology exists to monitor spinal cord ischemia. We recently demonstrated continuous monitoring of spinal cord ischemia with diffuse correlation and optical spectroscopies using an optical probe. Prior to clinical translation of this technology, it is critically important to demonstrate the safety profile of spinal cord exposure to the required light.
View Article and Find Full Text PDFCerebral autoregulation (CA) maintains cerebral blood flow (CBF) in the presence of systemic blood pressure changes. Brain injury can cause loss of CA and resulting dysregulation of CBF, and the degree of CA impairment is a functional indicator of cerebral tissue health. Here, we demonstrate a new approach to noninvasively estimate cerebral autoregulation in healthy adult volunteers.
View Article and Find Full Text PDFThe critical closing pressure ( CrCP) of the cerebral circulation depends on both tissue intracranial pressure and vasomotor tone. CrCP defines the arterial blood pressure ( ABP) at which cerebral blood flow approaches zero, and their difference ( ABP - CrCP) is an accurate estimate of cerebral perfusion pressure. Here we demonstrate a novel non-invasive technique for continuous monitoring of CrCP at the bedside.
View Article and Find Full Text PDFOptimization of cerebral blood flow (CBF) is the cornerstone of clinical management in a number of neurologic diseases, most notably ischemic stroke. Intrathoracic pressure influences cardiac output and has the potential to impact CBF. Here, we aim to quantify cerebral hemodynamic changes in response to increased respiratory impedance (RI) using a non-invasive respiratory device.
View Article and Find Full Text PDFWe introduce, validate and demonstrate a new software correlator for high-speed measurement of blood flow in deep tissues based on diffuse correlation spectroscopy (DCS). The software correlator scheme employs standard PC-based data acquisition boards to measure temporal intensity autocorrelation functions continuously at 50 - 100 Hz, the fastest blood flow measurements reported with DCS to date. The data streams, obtained in vivo for typical source-detector separations of 2.
View Article and Find Full Text PDFWe investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coefficient (γ) for the arm is determined, permitting conversion of DCS blood flow indices to absolute blood flow units, and a study of healthy adults (N=10) is carried out to ascertain the variability of γ.
View Article and Find Full Text PDFWe introduce and validate a pressure measurement paradigm that reduces extracerebral contamination from superficial tissues in optical monitoring of cerebral blood flow with diffuse correlation spectroscopy (DCS). The scheme determines subject-specific contributions of extracerebral and cerebral tissues to the DCS signal by utilizing probe pressure modulation to induce variations in extracerebral blood flow. For analysis, the head is modeled as a two-layer medium and is probed with long and short source-detector separations.
View Article and Find Full Text PDFSurgery is the most effective method to cure patients with solid tumors, and 50% of all cancer patients undergo resection. Local recurrences are due to tumor cells remaining in the wound, thus we explore near-infrared (NIR) fluorescence spectroscopy and imaging to identify residual cancer cells after surgery. Fifteen canines and two human patients with spontaneously occurring sarcomas underwent intraoperative imaging.
View Article and Find Full Text PDFDiffuse correlation spectroscopy (DCS) is an emerging optical modality used to measure cortical cerebral blood flow. This outlook presents a brief overview of the technology, summarizing the advantages and limitations of the method, and describing its recent applications to animal, adult, and infant cohorts. At last, the paper highlights future applications where DCS may play a pivotal role individualizing patient management and enhancing our understanding of neurovascular coupling, activation, and brain development.
View Article and Find Full Text PDFWe develop and validate a Modified Beer-Lambert law for blood flow based on diffuse correlation spectroscopy (DCS) measurements. The new formulation enables blood flow monitoring from temporal intensity autocorrelation function data taken at single or multiple delay-times. Consequentially, the speed of the optical blood flow measurement can be substantially increased.
View Article and Find Full Text PDFWe present a technique to quantitatively image the phase of thin quasi-transparent samples using extended source incoherent illumination and off-axis detection apertures. Our technique is achromatic and polarization independent, requires no active elements, and can be readily adapted to standard bright-field microscopes. We demonstrate our technique by quantitatively reconstructing the phase of cheek cells and a microlens.
View Article and Find Full Text PDFLaser Speckle Contrast Imaging (LSCI) has become a widely used technique to image cerebral blood flow in vivo. However, the quantitative accuracy of blood flow changes measured through the thin skull has not been investigated thoroughly. We recently developed a new Multi Exposure Speckle Imaging (MESI) technique to image blood flow while accounting for the effect of scattering from static tissue elements.
View Article and Find Full Text PDFMonitoring cerebral blood flow (CBF) during neurosurgery can provide important physiological information for a variety of surgical procedures. CBF measurements are important for assessing whether blood flow has returned to presurgical baseline levels and for assessing postsurgical tissue viability. Existing techniques for intraoperative monitoring of CBF based on magnetic resonance imaging are expensive and often impractical, while techniques such as indocyanine green angiography cannot produce quantitative measures of blood flow.
View Article and Find Full Text PDFBackground And Objective: The objective of this article is to quantify the effect of hyper-osmotic agent (glycerol) on blood velocity in hamster skin blood vessels measured with a dynamic imaging technique, laser speckle contrast imaging (LSCI).
Study Design/materials And Methods: In this study a dorsal skin-flap window was implanted on the hamster skin. The hyper-osmotic drug, that is, glycerol was delivered to the skin through the open dermal end of the window model.
Laser Speckle Contrast Imaging (LSCI) is a minimally invasive full field optical technique used to generate blood flow maps with high spatial and temporal resolution. The lack of quantitative accuracy and the inability to predict flows in the presence of static scatterers such as an intact or thinned skull have been the primary limitation of LSCI. We present a new Multi-Exposure Speckle Imaging (MESI) instrument that has potential to obtain quantitative baseline flow measures.
View Article and Find Full Text PDF