J Hand Surg Eur Vol
September 2024
The ReMotion wrist replacement has good short- to medium-term survival with an acceptable complication profile as we previously reported in a cohort of patients with rheumatoid arthritis. We now report the long-term results of the same cohort and details of explant analysis of revisions undertaken for aseptic loosening. A total of 16 wrists were reviewed.
View Article and Find Full Text PDFBackground: Developmental dysplasia of the hip (DDH) describes the abnormal development of a hip in childhood, ranging from complete dislocation of the hip joint to subtle immaturity of a hip that is enlocated and stable within the socket. DDH occurs in around 10 per 1000 live births, though only one per 1000 are completely dislocated. There is variation in treatment pathways for DDH, which differs between hospitals and even between clinicians within the same hospital.
View Article and Find Full Text PDFThe dynamic hip screw (DHS) consists of a barrel-plate fixed to the relatively-straight proximal femoral shaft, and a screw which slides within the barrel at a fixed angle, usually 135°. The guide-wire is inserted using a guide at the set angle. Guide design varies between manufacturers, with some new guides being particularly short.
View Article and Find Full Text PDFAim: This study aimed to determine if the ratio of cortical thickness to shaft diameter of the humerus, as measured on a simple anterior-posterior shoulder radiograph, is associated with surgical fixation failure.
Patients And Methods: 64 consecutive fractures in 63 patients (mean age 66.1 years, range 35-90) operated with surgical fixation between March 2011 and July 2014 using PERI-LOC locking plate and screws (Smith and Nephew, UK) were identified.
The aims of the study were to quantify the litigation cost of scaphoid mismanagement, identify the main reasons why patients sought compensation and hence provide suggestions for reducing litigation. Data were obtained from the National Health Service Litigation Authority. All orthopaedic-related litigation between 1995 and 2010 in the UK was reviewed.
View Article and Find Full Text PDFEvidence shows that raised cobalt (Co), chromium (Cr), and nickel (Ni) whole blood concentrations correlate with poor device outcome in patients following metal-on-metal (MoM) hip arthroplasty. To understand the local and systemic pathological effects of these raised metal concentrations it is important to define their distribution between whole blood, plasma, and urine. The metals were measured by Inductively Coupled Plasma Mass Spectrometry (ICPMS).
View Article and Find Full Text PDF