Purpose: The impact of a gravimetric-based technology-assisted workflow (TAWF) system on hazardous compounded sterile product (CSP) production time, staff perception of safety, and job satisfaction was evaluated.
Methods: For 2 weeks before implementation of a gravimetric-based TAWF, staff utilized an automated punch clock to document the time to prepare and check CSPs compounded volumetrically. Simultaneously, an anonymous, online survey was e-mailed to staff to evaluate their perceptions regarding the safety of volumetric preparation and satisfaction with their role preparing CSPs.