Dtsch Med Wochenschr
February 2023
20 years of colonoscopy for early cancer detection and screening in Germany. A success story - there is no longer any doubt about that, but a critical look should not be missing either.
View Article and Find Full Text PDFBackground And Aims: Randomized studies have demonstrated that a distal attachment cap with rubber side arms, the Endocuff Vision (ECV; Olympus America, Center Valley, Pa, USA), increased colonoscopic adenoma detection rate (ADR) in various mixed patient collectives. This is the first study to evaluate its use in a primary colonoscopic screening program.
Methods: Patients over age 55 years undergoing screening colonoscopy in 9 German private offices in Berlin and Hamburg were randomized to either the study group using ECV or the control group using high-definition colonoscopies (standard of care).
Background & Aims: Point of care tests (POCTs) might be used to identify patients with undiagnosed celiac disease who require further evaluation. We performed a large multicenter study to determine the performance of a POCT for celiac disease and assessed celiac disease prevalence in endoscopy centers.
Methods: We performed a prospective study of 1055 patients (888 adults; median age, 48 yrs and 167 children; median age, 10 yrs) referred to 8 endoscopy centers in Germany, for various indications, from January 2016 through June 2017.
Background And Aims: Sufficient bowel preparation is crucial for successful screening and surveillance colonoscopy. However, the rates of inadequate preparation are still high. We investigated the effects of reinforcing patient education and guidance by using the short message service (SMS).
View Article and Find Full Text PDFBackground: Previous studies have shown that multiple colonoscope features have to be changed before an improvement in adenoma detection rate (ADR) becomes obvious, such as with changing from one instrument generation to the next but one. We wanted to evaluate whether such an effect can also be observed in a private-practice screening setting.
Methods: In a randomized study, we compared the latest generation colonoscopes from one company (Olympus Exera III, 190) with the next to last one (Olympus 165), including only patients presenting for screening colonoscopy.
Clin Gastroenterol Hepatol
November 2018
Background & Aims: A higher incidence of proximal interval cancers after colonoscopy has been reported in several follow-up studies. One possible explanation for this might be that proximally located adenomas have greater malignant potential. The aim of the present study was to assess the risk of malignancy in proximal versus distal adenomas in patients included in a large screening colonoscopy database; adenoma shape and the patients' age and sex distribution were also analyzed.
View Article and Find Full Text PDFBackground And Study Aims: The German screening colonoscopy program is accompanied by a central registry that records the main outcome quality indicators, namely colonoscopy completion rate, adenoma detection rate (ADR), and complication rate. The aim of the present study was to assess the quality of these registry data by comparing them with data from a prospective quality assurance study based on a self-reporting audit and patient feedback of screening colonoscopy.
Patients And Methods: The completeness of registry information was analyzed by comparing it with prospective data gathered by audit and patient feedback in a previous quality assurance study (ClinicalTrials.
Background: As screening colonoscopy becomes more widespread, the costs for histopathological assessment of resected polyps are rising correspondingly. Reference centres have published highly accurate results for endoscopic polyp classification. Therefore, it has been proposed that, for smaller polyps, the differential diagnosis that guides follow-up recommendations could be based on endoscopy alone.
View Article and Find Full Text PDFBackground: Screening colonoscopy (SC) outcome quality is best determined by the adenoma detection rate (ADR). The substantial variability in the ADRs between endoscopists may reflect different skills, experience and/or equipment.
Objective: To analyse the potential factors that may influence ADR variance, including case volume.
Clin Gastroenterol Hepatol
February 2012
Background & Aims: Improvements to endoscopy imaging technologies might improve detection rates of colorectal cancer and patient outcomes. We compared the accuracy of the latest generation of endoscopes with older generation models in detection of colorectal adenomas.
Methods: We compared data from 2 prospective screening colonoscopy studies (the Berlin Colonoscopy Project 6); each study lasted approximately 6 months and included the same 6 colonoscopists, who worked in private practice.
Objectives: Fujinon intelligent chromoendoscopy (FICE) is a post-processing imaging technique for increasing contrast of mucosa and mucosal lesions that might lead to improvement in colonic adenoma detection during colonoscopy. Previous studies on similar contrast-enhancing techniques as well as on dye staining have yielded variable and conflicting results. This large randomized trial was undertaken to determine whether FICE technology enhances adenoma detection rate (ADR).
View Article and Find Full Text PDFBackground & Aims: Narrow-band imaging (NBI) has been implemented in gastrointestinal endoscopy to improve the contrast of endoluminal pathologic structures, one of the aims being to increase colonic adenoma detection. Previous studies from referral centers have yielded variable and conflicting results with regard to improvement in adenoma detection rates by using NBI. The present large randomized trial was designed to finally settle this issue.
View Article and Find Full Text PDFObjective: Potential process differences between hospital and community-based endoscopy for Barrett's oesophagus have not been examined. We aimed at comparing adherence to guidelines and neoplasia detection rates in medical centres (MC) and community practices (CP).
Design: Retrospective analysis.